16 resultados para Measuring intangible assets
em Scielo Saúde Pública - SP
Resumo:
This study describes the concept of corporate reputation and reviews some of the major points that exist when it comes to measuring it. It thus suggests a new index for measurement and its advantages and disadvantages are pointed out. The consistency of the seven key variables for the collecting indicator is described by the results of a factor analysis and correlations. Finally, the indicator is put to test by gathering the perception of corporate reputation of 1500 individuals for 69 companies belonging to 15 different industrial sectors, in Peru. The results indicate that the proposed index variables are not necessarily of greatest interest to the study sample in which companies have a better performance. Also greater memorial companies aren't necessarily those that enjoy a greater corporate reputation. Managerial implications for the organizations in the process of managing and monitoring the dimensions involved of this key asset are also referenced.
Resumo:
A series of studies in the field of Epidemiological Psychiatry have been performed over the last two decades, and these have focused on the ability of primary care physicians to detect emotional disorders in the patients that attend their practices. The scientific methodology utilized in these studies is the subject of this review, which contains a discussion concerning: a) interviewer awareness bias; b) accuracy of the instruments and c) medical and psychological concepts involved in defining minor emotional disorders. Suggestions for change in the methodology are made in each of the sections of the review.
Resumo:
To determine the precision and agreement of the hemoglobin (Hb) measurements in capillary and venous blood samples by the HemoCue® and an automated counter. Hb was determined by both equipaments in blood samples of 29 pregnant women. The HemoCue® showed low repeatability of Hb measurements in duplicate in capillary (CR=0.53 g/dL, CV=13.6%) and venous blood (CR=0.53 g/dL, CV=13.6%). Hb measurements in capillary blood were higher than those in venous blood (12.4 and 11.7 g/dL, respectively; p<0.05). There was high agreement between Hb in capillary blood by the HemoCue® and in venous blood by the counter (r icc=0.86; p<0.01), and also between the diagnosis of anemia by both equipments (k=0.81; p<0.01). The HemoCue® seems to be more appropriate for capillary blood and require training of the measurers.
Resumo:
Evidence suggests that human semen quality may have been deteriorating in recent years. Most of the evidence is retrospective, based on analysis of data sets collected for other purposes. Measures of male infertility are needed if we want to monitor the biological capacity for males to reproduce over time or between different populations. We also need these measures in analytical epidemiology if we want to identify risk indicators, risk factors, or even causes of an impaired male fecundity-that is, the male component in the biological ability to reproduce. The most direct evaluation of fecundity is to measure the time it takes to conceive. Since the time of conception may be missed in the case of an early abortion, time to get pregnant is often measured as the time it takes to obtain a conception that survives until a clinically recognized pregnancy or even a pregnancy that ends with a live born child occurs. A prolonged time required to produce pregnancy may therefore be due to a failure to conceive or a failure to maintain a pregnancy until clinical recognition. Studies that focus on quantitative changes in fecundity (that does not cause sterility) should in principle be possible in a pregnancy sample. The most important limitation in fertility studies is that the design requires equal persistency in trying to become pregnant and rather similar fertility desires and family planning methods in the groups to be compared. This design is probably achievable in exposure studies that make comparisons with reasonable comparable groups concerning social conditions and use of contraceptive methods.
Resumo:
OBJECTIVE: To evaluate the performance of the turbidimetric method of C-reactive protein (CRP) as a measure of low-grade inflammation in patients admitted with non-ST elevation acute coronary syndromes (ACS). METHODS: Serum samples obtained at hospital arrival from 68 patients (66±11 years, 40 men), admitted with unstable angina or non-ST elevation acute myocardial infarction were used to measure CRP by the methods of nephelometry and turbidimetry. RESULTS: The medians of C-reactive protein by the turbidimetric and nephelometric methods were 0.5 mg/dL and 0.47 mg/dL, respectively. A strong linear association existed between the 2 methods, according to the regression coefficient (b=0.75; 95% C.I.=0.70-0.80) and correlation coefficient (r=0.96; P<0.001). The mean difference between the nephelometric and turbidimetric CRP was 0.02 ± 0.91 mg/dL, and 100% agreement between the methods in the detection of high CRP was observed. CONCLUSION: In patients with non-ST elevation ACS, CRP values obtained by turbidimetry show a strong linear association with the method of nephelometry and perfect agreement in the detection of high CRP.
Resumo:
The observation that murine thymocytes increase their proliferation to interleukin 1 (IL-1) in the presence of phytohemagglutinin (PHA) when pre-incubated with interleukin 2 (IL-2) allowed the introduction of a modified assay for the measurement of IL-1 or the search of thymocyte-inducing proliferative activities in biological samples. Pre-incubation of thymocytes for 24 hr with 50 u/ml IL-2, followed by washings, elicited their maximal response to IL-1 in the usual lymphocyte activating factor (LAF) assay. This suggests that sequential events lead to thymocyte activation. The responsiveness is three to five fold greater than, and the total time of assay is the same as that of the LAF assay. Interestingly, pre-incubation with IL-2 renders thymocytes more sensitive than responsive to crude monocyte conditioned media. The use of the MTT colorimetric method for the assessment of thymocyte proliferation, and of the lectin jacalin as a co-mitogen are suggested as alternatives to be used in co-stimulatory assays.
Resumo:
This was a systematic review aimed at identifying and characterizing measuring instruments, developed in the context of cardiology, which were adapted into Portuguese language of Brazil. Systematic searches were performed in six databases. Information extracted included cultural adaptation process and measurement properties. To assess the methodological quality of studies, criteria based on international guidelines for cultural adaptation of instruments were used. Among the 114 articles found, 14 were eligible for review. Of these, most evaluated quality of life (35.7%) and health knowledge/learning (28.6%). Most studies followed all stages of the adaptation process recommended in the literature. With respect to measurement properties, internal consistency, verified by Cronbach’s alpha, was the property reported in the majority of the studies, as well as construct and criterion validity. This study is expected to provide to the scientific community a critical evaluation of adapted questionnaires available in the context of cardiology.
Resumo:
Objetivo: Comparar a gravidade das lesões e do trauma mensurada pelas versões da Abbreviated Injury Scale 1998 e 2005 e verificar a mortalidade nos escores Injury Severity Score e New Injury Severity Score nas duas versões.Método: Estudo transversal e retrospectivo analisou lesões de pacientes de trauma, de três hospitais universitários do município de São Paulo, Brasil. Cada lesão foi codificada com Abbreviated Injury Scale 1998 e 2005. Os testes estatísticos aplicados foram Wilcoxon, McNemar-Bowker, Kappa e teste Z.Resultados: A comparação das duas versões resultou em discordância significante de escores em algumas regiões corpóreas. Com a versão 2005 os níveis de gravidade da lesão e do trauma foram significantemente reduzidos e a mortalidade foi mais elevada em escores mais baixos. Conclusão: Houve redução da gravidade da lesão e do trauma e alteração no percentual de mortalidade com o uso da Abbreviated Injury Scale 2005.
Resumo:
ABSTRACT Objective To explore potential associations between nursing workload and professional satisfaction among nursing personnel (NP) in Greek Coronary Care Units (CCUs). Method A cross-sectional study was performed involving 66 members of the NP employed in 6 randomly selected Greek CCUs. Job satisfaction was assessed by the IWS and nursing workload by NAS, CNIS and TISS-28. Results The response rate was 77.6%. The reliability of the IWS was α=0.78 and the mean score 10.7 (±2.1, scale range: 0.5-39.7). The most highly valued component of satisfaction was “Pay”, followed by “Task requirements”, “Interaction”, “Professional status”, “Organizational policies” and “Autonomy”. NAS, CNIS and TISS-28 were negatively correlated (p≤0.04) with the following work components: “Autonomy”, “Professional status”, “Interaction” and “Task requirements”. Night shift work independently predicted the score of IWS. Conclusion The findings show low levels of job satisfaction, which are related with nursing workload and influenced by rotating shifts.
Resumo:
Mechanical impedance of clayey and gravelly soils is often needed to interpret experimental results from tillage and other field experiments. Its measurement is difficult with manual and hydraulic penetrometers, which often bend or break in such soils. The purpose of this study was to evaluate the feasibility of a hand-operated "Stolf" impact penetrometer to measure mechanical impedance (soil resistance). The research was conducted in Raleigh, North Carolina, USA (35º 45'N, 78º 42'W, elevation 75 m). Corn was planted on April 19, 1991. Penetrometer measurements were taken on May 10, 1991, in 5 cm intervals to 60 cm at 33 locations on a transect perpendicular to the corn rows in each of four tillage treatments. The data permitted three-dimensional displays showing how mechanical impedance changed with depth and distance along the transect. The impact penetrometer proved to be a useful tool to collect quantitative mechanical impedance data on "hard" clayey and/or gravelly soils which previously were difficult to reliably quantify.
Resumo:
The rate of carbon dioxide production is commonly used as a measure of microbial activity in the soil. The traditional method of CO2 determination involves trapping CO2 in an alkali solution and then determining CO2 concentration indirectly by titration of the remaining alkali in the solution. This method is still commonly employed in laboratories throughout the world due to its relative simplicity and the fact that it does not require expensive, specific equipment. However, there are several drawbacks: the method is time-consuming, requires large amounts of chemicals and the consistency of results depends on the operator's skills. With this in mind, an improved method was developed to analyze CO2 captured in alkali traps, which is cheap and relatively simple, with a substantially shorter sample handling time and reproducibility equivalent to the traditional titration method. A comparison of the concentration values determined by gas phase flow injection analysis (GPFIA) and titration showed no significant difference (p > 0.05), but GPFIA has the advantage that only a tenth of the sample volume of the titration method is required. The GPFIA system does not require the purchase of new, costly equipment but the device was constructed from items commonly found in laboratories, with suggestions for alternative configurations for other detection units. Furthermore, GPFIA for CO2 analysis can be equally applied to samples obtained from either the headspace of microcosms or from a sampling chamber that allows CO2 to be released from alkali trapping solutions. The optimised GPFIA method was applied to analyse CO2 released from degrading hydrocarbons from a site contaminated by diesel spillage.
Resumo:
In this communication we describe the application of a conductive polymer gas sensor as an air pressure sensor. The device consists of a thin doped poly(4'-hexyloxy-2,5-biphenylene ethylene) (PHBPE) film deposited on an interdigitated metallic electrode. The sensor is cheap, easy to fabricate, lasts for several months, and is suitable for measuring air pressures in the range between 100 and 700 mmHg.
Resumo:
The irrigation management based on the monitoring of the soil water content allows for the minimization of the amount of water applied, making its use more efficient. Taking into account these aspects, in this work, a sensor for measuring the soil water content was developed to allow real time automation of irrigation systems. This way, problems affecting crop yielding such as irregularities in the time to turn on or turn off the pump, and excess or deficit of water can be solved. To develop the sensors were used stainless steel rods, resin, and insulating varnish. The sensors measuring circuit was based on a microcontroller, which gives its output signal in the digital format. The sensors were calibrated using soil of the type Quartzarenic Neosoil. A third order polynomial model was fitted to the experimental data between the values of water content corresponding to the field capacity and the wilting point to correlate the soil water content obtained by the oven standard method with those measured by the electronic circuit, with a coefficient of determination of 93.17%, and an accuracy in the measures of ±0.010 kg kg-1. Based on the results, it was concluded that the sensor and its implemented measuring circuit can be used in the automation process of irrigation systems.
Resumo:
The degree of flowering and fruiting synchronization is believed to have ecological and evolutionary relevance at several scales. Here we discuss some measures that have been used to estimate synchrony and propose an index that incorporates both the entire length of an individual phenophase and variation in the number of flowers or fruits over that time period. This new index describes more accurately the phenological synchrony among individuals and populations.
Resumo:
Measurement of telomerase activity in clinically obtained tumor samples may provide important information for use as both a diagnostic marker and a prognostic indicator for patient outcome. In order to evaluate telomerase activity in tumor tissue without radiolabeling the product, we developed a simple telomeric repeat amplification protocol-silver-staining assay that is less time-consuming, is safe and requires minimal equipment. In addition, we determined the sensitivity of the silver-staining method by using extracts of telomerase-positive thyroid carcinoma cell lines which were serially diluted from 5,000 to 10 cells. Telomerase activity was also assayed in 19 thyroid tumors, 2 normal controls and 27 bone marrow aspirates. The results indicate that the technique permits the detection of telomerase activity from 5000 to as few as 10 cells. We propose that it could be immediately applicable in many laboratories due to the minimal amount of equipment required.