7 resultados para Loop spaces.

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The loop-mediated isothermal amplification method (LAMP) is a recently developed molecular technique that amplifies nucleic acid under isothermal conditions. For malaria diagnosis, 150 blood samples from consecutive febrile malaria patients, and healthy subjects were screened in Thailand. Each sample was diagnosed by LAMP, microscopy and nested polymerase chain reaction (nPCR), using nPCR as the gold standard. Malaria LAMP was performed using Plasmodiumgenus and Plasmodium falciparum specific assays in parallel. For the genus Plasmodium, microscopy showed a sensitivity and specificity of 100%, while LAMP presented 99% of sensitivity and 93% of specificity. For P. falciparum, microscopy had a sensitivity of 95%, and LAMP of 90%, regarding the specificity; and microscopy presented 93% and LAMP 97% of specificity. The results of the genus-specific LAMP technique were highly consistent with those of nPCR and the sensitivity of P. falciparum detection was only marginally lower.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:The recording of arrhythmic events (AE) in renal transplant candidates (RTCs) undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used.Objective:We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR).Methods:A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE.Results:During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT) occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002), and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001) were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD) was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041).Conclusions:In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies in mice with hypervitaminosis A have demonstrated that fat-storing cells (hepatic stellate cells-HSCs) participate in schistosomal granuloma fibrogenesis. The origin of such cells in portal areas, away from the Disse spaces, was herein investigated. HSCs were identified in frozen sections of the liver by means of Sudan III staining. They appeared as red-stained cells disposed along the sinusoids of normal mice, but were never found within portal spaces. However, in the chronically inflamed portal spaces of Capillaria hepatica-infected mice, Sudan III-positive cells were frequently present among leukocytes and fibroblast-like cells. Thus, there are no resident HSCs in portal spaces, but their presence there in chronic inflammatory processes indicates that they are able to migrate from peri-sinusoidal areas in order to reach the portal areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the development and validation of a loop-mediated isothermal amplification assay (LAMP) for the rapid and specific detection of Actinobacillus pleuropneumoniae (A. pleuropneumoniae). A set of six primers were designed derived from the dsbE-like gene of A.pleuropneumoniae and validate the assay using 9 A. pleuropneumoniae reference/field strains, 132 clinical isolates and 9 other pathogens. The results indicated that positive reactions were confirmed for all A. pleuropneumoniae strains and specimens by LAMP at 63ºC for 60 min and no cross-reactivity were observed from other non-A.pleuropneumoniae including Haemophilus parasuis, Escherichia coli, Pasteurella multocida, Bordetella bronchiseptica, Streptococcus suis, Salmonella enterica, Staphylococcus, porcine reproductive and respiratory syndrome virus (PRRSV), and Pseudorabies virus. The detection limit of the conventional PCR was 10² CFU per PCR test tube, while that of the LAMP was 5 copies per tube. Therefore, the sensitivity of LAMP was higher than that of PCR. Moreover, the LAMP assay provided a rapid yet simple test of A. pleuropneumoniae suitable for laboratory diagnosis and pen-side detection due to ease of operation and the requirement of only a regular water bath or heat block for the reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bordetella bronchiseptica causes acute and chronic respiratory infections in diverse animal species and occasionally in humans. In this study, we described the establishment of a simple, sensitive and cost-efficient loop-mediated isothermal amplification (LAMP) assay for the detection of B. bronchiseptica. A set of primers towards a 235 bp region within the flagellum gene of B. bronchiseptica was designed with online software.. The specificity of the LAMP assay was examined by using 6 porcine pathogens and 100 nasal swabs collected from healthy pigs and suspect infected pigs. The results indicated that positive reactions were confirmed for all B. bronchiseptica and no cross-reactivity was observed from other non-B. bronchiseptica. In sensitivity evaluations, the technique successfully detected a serial dilutions of extracted B. bronchiseptica DNA with a detection limit of 9 copies, which was 10 times more sensitive than that of PCR. Compared with conventional PCR, the higher sensitivity of LAMP method and no need for the complex instrumentation make this LAMP assay a promising alternative for the diagnosis of B. bronchiseptica in rural areas and developing countries where there lacks of complex laboratory services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We recently demonstrated that the substitution of the autolysis loop (residues 143 to 154 in the chymotrypsin numbering system) of activated protein C (APC) with the corresponding loop of factor Xa (fXa) renders the APC mutant (APC/fX143-154) susceptible to inhibition by antithrombin (AT) in the presence of pentasaccharide. Our recent results further indicated, that in addition to an improvement in the reactivity of APC/fX143-154 with AT, both the amidolytic and anti-factor Va activities of the mutant APC have also been significantly increased. Since the autolysis loop of APC is five residues longer than the autolysis loop of fXa, it could not be ascertained whether this loop in the mutant APC specifically interacts with the activated conformation of AT or if a shorter autolysis loop is responsible for a global improvement in the catalytic activity of the mutant protease. To answer this question, we prepared another APC mutant in which the autolysis loop of the protease was replaced with the corresponding loop of trypsin (APC/Tryp143-154). Unlike an ~500-fold improvement in the reactivity of APC/fX143-154 with AT in the presence of pentasaccharide, the reactivity of APC/Tryp143-154 with the serpin was improved ~10-fold. These results suggest that both the length and structure of residues of the autolysis loop are critical for the specificity of the coagulation protease interaction with AT. Further factor Va inactivation studies with the APC mutants revealed a similar role for the autolysis loop of APC in the interaction with its natural substrate.