6 resultados para LASER FREQUENCY MEASUREMENTS

em Scielo Saúde Pública - SP


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper describes an electronic transducer for multiphase flow measurement. Its high sensitivity, good signal to noise ratio and accuracy are achieved through an electrical impedance sensor with a special guard technique. The transducer consists of a wide bandwidth and high slew rate differentiator where the lead inductance and stray capacitance effects are compensated. The sensor edge effect is eliminated by using a guard electrode based on the virtual ground potential of the operational amplifier. A theoretical modeling and a calibration method are also presented. The results obtained seem to confirm the validity of the proposed technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effectiveness, recurrence rate, and complications of carbon-dioxide laser vaporization in the treatment of Bartholin's gland cysts. METHODS: A retrospective study including 127 patients with symptomatic Bartholin' gland cysts submitted to carbon-dioxide laser vaporization at our institution from January 2005 to June 2011. Patients with Bartholin's gland abscesses and those suspected of having neoplasia were excluded. All procedures were performed in an outpatient setting under local anaesthesia. Clinical records were reviewed for demographic characteristics, anatomic parameters, intraoperative and postoperative complications, and follow-up data. Data were stored and analyzed in Microsoft Excel® 2007 software. A descriptive statistical analysis was performed, and its results were expressed as frequency (percentage) or mean±standard deviation. Complication, recurrence, and cure rates were calculated. RESULTS: The mean age of the patients was 37.3±9.5 years-old (range from 18 to 61 years-old). Seventy percent (n=85) of them were multiparous. The most common symptom was pain and 47.2% (n=60) of patients had a history of previous medical and/or surgical treatment for Bartholin's gland abscesses. Mean cyst size was 2.7±0.9 cm. There were three (2.4%) cases of minor intraoperative bleeding. Overall, there were 17 (13.4%) recurrences within a mean of 14.6 months (range from 1 to 56 months): ten Bartholin's gland abscesses and seven recurrent cysts requiring reintervention. The cure rate after single laser treatment was 86.6%. Among the five patients with recurrent disease that had a second laser procedure, the cure rate was 100%. CONCLUSIONS: At this institution, carbon-dioxide laser vaporization seems to be a safe and effective procedure for the treatment of Bartholin's gland cysts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Venturi scrubbers are high efficiency gas cleaners in which suspended particles are removed from gas streams by droplets formed by liquid atomisation, usually in the venturi throat. The size of the droplets formed is of fundamental importance to the performance of the equipment, both in terms of pressure drop and collection efficiency. In this study, drop sizes in a cylindrical laboratory scale venturi scrubber were measured using a laser diffraction technique. Gas velocity and liquid to gas ratios varied from 50 to 90 m/s and 0.5 to 2.0 l/m3, respectively. Water was inserted as perpendicular jets at the beginning of the throat. Measurements were performed at three positions: two located along the throat, and the last one at the end of the diffuser. The data presented here are a typical example of pneumatic atomisation and can be relevant to other industrial applications such as combustion and engine technology. Finally, results are compared to available correlations and the validity of these equations is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compares contrast thresholds for sinewave gratings, or spatial frequencies (1/CSF) with contrast thresholds for angular frequencies (1/aCSF) and for radial frequencies, or J0 targets (1/rCSF). Observers had to differentiate between one of these frequency stimuli and a stimulus at mean luminance within a forced-choice procedure. All measurements were made with the same equipment, methods and subjects. Our results show higher sensitivity to, or lower thresholds for, angular frequencies when compared to either sinewave gratings or J0 targets. Contrast values in arbitrary units, in the lower threshold range for angular frequencies, were about half those required to differentiate sinewave gratings from mean luminance in its most sensitive range

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to measure contrast sensitivity curves for angular frequencies in the range between 2 and 96 cycles/360º in older human adult volunteers and to compare these measurements with the more usual contrast sensitivity functions for sine-wave gratings. All subjects were free of identifiable ocular disease and had normal acuity. We measured the contrast thresholds for young adults (N = 6; age range, 20-26 years) and older adults (N = 6; age range, 60-67 years) using the psychophysical forced-choice method. In this paradigm the volunteers had to choose the stimulus containing a test frequency at low contrast (e.g., either a sine-wave grating or an angular frequency stimulus), or another neutral stimulus at mean luminance (without any contrast). Older adults presented a loss in contrast sensitivity at high and medium angular frequencies compared to the young adults (i.e., from 8 to 96 cycles/360º). Contrary to expectation, contrast sensitivity at low angular frequencies, i.e., 2 and 4 cycles/360º, was better for the older group than for the younger group. On the other hand, contrast sensitivity for sine-wave gratings at 3 and 4 cpd was higher for young adults as expected. These results suggest age-related changes in the contrast sensitivity function for angular frequencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of colored microspheres to adequately evaluate blood flow changes under different circumstances in the same rat has been validated with a maximum of three different colors due to methodological limitations. The aim of the present study was to validate the use of four different colors measuring four repeated blood flow changes in the same rat to assess the role of vasopressor systems in controlling arterial pressure (AP). Red (150,000), white (200,000), yellow (150,000), and blue (200,000) colored microspheres were infused into the left ventricle of 6 male Wistar rats 1) at rest and 2) after vasopressin (aAVP, 10 µg/kg, iv), 3) renin-angiotensin (losartan, 10 mg/kg, iv), and 4) sympathetic system blockade (hexamethonium, 20 mg/kg, iv) to determine blood flow changes. AP was recorded and processed with a data acquisition system (1-kHz sampling frequency). Blood flow changes were quantified by spectrophotometry absorption peaks for colored microsphere components in the tissues evaluated. Administration of aAVP and losartan slightly reduced the AP (-5.7 ± 0.5 and -7.8 ± 1.2 mmHg, respectively), while hexamethonium induced a 52 ± 3 mmHg fall in AP. The aAVP injection increased blood flow in lungs (78%), liver (117%) and skeletal muscle (>150%), while losartan administration enhanced blood flow in heart (126%), lungs (100%), kidneys (80%), and gastrocnemius (75%) and soleus (94%) muscles. Hexamethonium administration reduced only kidney blood flow (50%). In conclusion, four types of colored microspheres can be used to perform four repeated blood flow measurements in the same rat detecting small alterations such as changes in tissues with low blood flow.