27 resultados para Intraocular aberration

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC method was developed and validated aiming to quantify the cyclosporine-A incorporated into intraocular implants, released from them; and in direct contact with the degradation products of PLGA. The separation was carried out in isocratic mode using acetonitrile/water (70:30) as mobile phase, a C18 column at 80 ºC and UV detection at 210 nm. The method provided selectivity based on resolution among peaks. It was linear over the range of 2.5-40.0 µg/mL. The quantitation and detection limits were 0.8 and 1.2 µg/mL, respectively. The recovery was 101.8% and intra-day and inter-day precision was close to 2%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare the normal intraocular pressure (IOP) and tear secretion, by means of applanation tonometry and the Schirmer tear test-1 (STT-1), in goats of the Saanen breed with different ages, and at different time points. Thirty six goats, free of ocular abnormalities, were grouped into three different age categories (n=12), animals with 45, 180 and 549 days of age. STT-1 and IOP measurements were carried out always at 9:00am and 7:00pm, during three consecutive days. Results were evaluated statistically (P<0.05). Regarding the time of the day, overall IOP values were significantly lower at 7:00 pm (P<0.001) in individuals with 45 days of age; whereas STT-1 values were significantly higher at 7:00pm (P=0.004) in goats with 549 days of age. Considering the sum of three days, both parameters were significantly lower in individuals with 45 days of age (P<0.001). Intraocular pressure and tear secretion values increase until 180 days of age in the Saanen breed of goats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to establish reference values for selected ophthalmic diagnostic tests in New Zealand rabbits (Oryctolagus cuniculus). A total of 22 adult male rabbits were used. The ophthalmic tests included evaluation of tear production with Schirmer tear test 1(STT1) and Endodontic absorbent paper point tear test (EAPPTT) using two different commercial brand materials. Applanation tonometry, Culture of the conjunctival bacterial flora, , conjunctival cytology and conjunctival histology were also performed. Mean (±SD) for STT1, EAPPTTa, EAPPTTb and IOP was 7.27±2.51mm/min, 12.43±1.69mm/min, 15.24±2.07mm/min, 12.89±2.80mm Hg, respectively. Staphylococcus epidermidis, Staphylococcus sp. and Bacillus sp. were predominant. The cytological evaluation revealed the presence columnar epithelial cells, superficial squamous keratinized cells, lymphocytes, heterophils, red blood cells, mucus and bacteria. The histological analysis revealed a stratified epithelium, characterized by the presence of columnar epithelial cells with a large number of goblet cells. The reported data can be used for therapeutic or experimental purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this prospective study was to evaluate the efficacy and complications of the use of an intraocular sustained-release ganciclovir implant for the treatment of active cytomegalovirus (CMV) retinitis in AIDS patients. Thirty-nine eyes of 26 patients were submitted to ocular surgery. All patients underwent complete ocular examination before and after surgery. The surgical procedure was always done under local anesthesia using the same technique. The mean time for the surgical procedure was 20 min (range, 15 to 30 min). The average follow-up period was 3.7 months. Of all patient, only 4 presented recurrence of retinitis after 8, 8, 9 and 2 months, respectively. Three of them received a successful second implant. All 39 eyes of the 26 patients presented healing of retinitis as shown by clinical improvement evaluated by indirect binocular ophthalmoscopy and retinography. Retinitis healed within a period of 4 to 6 weeks in all patients, with clinical regression signs from the third week on. Six (15.4%) eyes developed retinal detachment. None of the patients developed CMV retinitis in the contralateral eye. The intraocular implant proved to be effective in controlling the progression of retinitis for a period of up to 8 months even in patients for whom systemic therapy with either ganciclovir or foscarnet or both had failed. The intraocular sustained-release ganciclovir implant proved to be a safe new procedure for the treatment of CMV retinitis, avoiding the systemic side effects caused by the intravenous medications and improving the quality of life of the patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of exercise and water replacement on intraocular pressure (IOP) have not been well established. Furthermore, it is not known whether the temperature of the fluid ingested influences the IOP response. In the present study we determined the effect of water ingestion at three temperatures (10, 24 and 38ºC; 600 ml 15 min before and 240 ml 15, 30 and 45 min after the beginning of each experimental session) on the IOP of six healthy male volunteers (age = 24.0 ± 3.5 years, weight = 67.0 ± 4.8 kg, peak oxygen uptake (VO2peak) = 47.8 ± 9.1 ml kg-1 min-1). The subjects exercised until exhaustion on a cycle ergometer at a 60% VO2peak in a thermoneutral environment. IOP was measured before and after exercise and during recovery (15, 30 and 45 min) using the applanation tonometry method. Skin and rectal temperatures, heart rate and oxygen uptake were measured continuously. IOP was similar for the right eye and the left eye and increased post-water ingestion under both exercising and resting conditions (P<0.05) but did not differ between resting and exercising situations, or between the three water temperatures. Time to exhaustion was not affected by the different water temperatures. Rectal temperature, hydration status, heart rate, oxygen uptake, carbon dioxide extraction and lactate concentration were increased by exercise but were not affected by water temperature. We conclude that IOP was not affected by exercise and that water ingestion increased IOP as expected, regardless of water temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to study the effects of exercise training (ET) performed by rats on a 10-week high-fructose diet on metabolic, hemodynamic, and autonomic changes, as well as intraocular pressure (IOP). Male Wistar rats receiving fructose overload in drinking water (100 g/L) were concomitantly trained on a treadmill for 10 weeks (FT group) or kept sedentary (F group), and a control group (C) was kept in normal laboratory conditions. The metabolic evaluation comprised the Lee index, glycemia, and insulin tolerance test (KITT). Arterial pressure (AP) was measured directly, and systolic AP variability was performed to determine peripheral autonomic modulation. ET attenuated impaired metabolic parameters, AP, IOP, and ocular perfusion pressure (OPP) induced by fructose overload (FT vs F). The increase in peripheral sympathetic modulation in F rats, demonstrated by systolic AP variance and low frequency (LF) band (F: 37±2, 6.6±0.3 vs C: 26±3, 3.6±0.5 mmHg2), was prevented by ET (FT: 29±3, 3.4±0.7 mmHg2). Positive correlations were found between the LF band and right IOP (r=0.57, P=0.01) and left IOP (r=0.64, P=0.003). Negative correlations were noted between KITT values and right IOP (r=-0.55, P=0.01) and left IOP (r=-0.62, P=0.005). ET in rats effectively prevented metabolic abnormalities and AP and IOP increases promoted by a high-fructose diet. In addition, ocular benefits triggered by exercise training were associated with peripheral autonomic improvement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spheres of different types of material are used for the replacement of lost volume after removal of the eye bulb or its content to prevent contraction of the orbital cavity. The aim of this study was to evaluate the scope of polymethylmethacrylate (PMMA) used as intraocular implant in eviscerated rabbit eye. Twelve New Zealand rabbits underwent unilateral evisceration of the left eye, with subsequent implantation of PMMA sphere 12 mm in diameter. Clinical evaluation was performed daily during the first 15 days after surgery and every 15 days until the end of the study period (180 days). For the histopathological analysis, three animals per trial underwent enucleation at 15, 45, 90 and 180 days after evisceration. There was no wound dehiscence, signs of infection or implant extrusion in any animal throughout the study period. Histological examination revealed the formation of fibrovascular tissue around the implants. The PMMA behaved as inert and non-integrable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Foi realizada pesquisa de anticorpos IgG, IgM e IgA anti-Toxoplasma gondii no soro e fluidos intra-oculares (humor aquoso e vítreo) de pacientes com toxoplasmose ocular. A partir dos resultados obtidos verificou-se que anticorpos IgG e IgA intraocular anti-Toxoplasma gondii podem vir a ser importantes marcadores no diagnóstico de toxoplasmose ocular.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to determine the prevalence of ocular lesions in HTLV-1 infected patients in Salvador Bahia, a transversal study was conducted on 140 HTLV-1 infected patients (90 asymptomatic and 50 tropical spastic paraparesis/HTLV-1-associated myelopathy) between June 2004 and November 2005. The ophthalmological examination included visual acuity measurement, ocular motility, biomicroscopy of the anterior and posterior chambers, intraocular pressure and evaluation of lachrymal secretion. Observation verified 4 (2.8%) out of 140 patients with uveitis (two patients had intermediate uveitis and two had pan-uveitis) and 39 (36.4%) out of 107 patients with keratoconjunctivitis sicca. The prevalence of Keratoconjunctivitis sicca was significantly higher among the TSP/HAM patients (OR age adjusted=3.64; 95%CI 1.59-8.32). Uveitis and corneal opacities were also important findings, indicating the strong need for periodic ophthalmological follow-up in all HTLV-1 subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:The ACUITY and CRUSADE scores are validated models for prediction of major bleeding events in acute coronary syndrome (ACS). However, the comparative performances of these scores are not known.Objective:To compare the accuracy of ACUITY and CRUSADE in predicting major bleeding events during ACS.Methods:This study included 519 patients consecutively admitted for unstable angina, non-ST-elevation or ST-elevation myocardial infarction. The scores were calculated based on admission data. We considered major bleeding events during hospitalization and not related to cardiac surgery, according to the Bleeding Academic Research Consortium (BARC) criteria (type 3 or 5: hemodynamic instability, need for transfusion, drop in hemoglobin ≥ 3 g, and intracranial, intraocular or fatal bleeding).Results:Major bleeding was observed in 31 patients (23 caused by femoral puncture, 5 digestive, 3 in other sites), an incidence of 6%. While both scores were associated with bleeding, ACUITY demonstrated better C-statistics (0.73, 95% CI = 0.63 - 0.82) as compared with CRUSADE (0.62, 95% CI = 0.53 - 0.71; p = 0.04). The best performance of ACUITY was also reflected by a net reclassification improvement of + 0.19 (p = 0.02) over CRUSADE’s definition of low or high risk. Exploratory analysis suggested that the presence of the variables ‘age’ and ‘type of ACS’ in ACUITY was the main reason for its superiority.Conclusion:The ACUITY Score is a better predictor of major bleeding when compared with the CRUSADE Score in patients hospitalized for ACS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Toxicological and toxicogenetic effects of aqueous (tea) and hexanica fruit extract of Indigofera suffruticosa Mill, and hydroalcoholic root extract od Solanum agrarium Stendt. Were evaluated in Balb C male mice intraperitoneally exposed. A hepatotoxic effect was observed just for animals treated with aqueous fruit extract of I. suffruticosa. In relation to the toxicogenetic effect, just the group trreated with 12.5% of toxic dose of aqueous fruit extract of I. suffruticosa showed a statistically significant increase in the frequency of cells with chromosome aberrations (cytogenetic effect), although a slight increase was also observed for the highest dose (25% of LF50_ of hydroalcoholic root extract of S. agrarium. The results obtanied show that before S. agrarium is used as medicine and before the wide use of I. suffruticosa in cattle food, careful evaluation must be done.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ophthalmic viscosurgical devices (OVD) are materials injected in intraocular space during cataract removal to reduce trauma in the patient's eye. Three Brazilian commercially available OVDs (Medilon®, Metilcelulose® and Ofthyal®) were evaluated as well as formulations based on Dimorphandra gardneriana galactomannan. Viscosity and viscoelastic parameters, such as viscosity at zero shear, pseudoplasticity index, elastic and viscous moduli, relaxation time, were determined and compared. Characteristics of an effective OVD were proposed. None of the Brazilian devices studied fulfill the rheological requirements. Only the galactomannan at 3% concentration showed potential to be used as effective OVD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cyclosporine-A-loaded PLGA implants were developed intended for ocular route. Implants were prepared using solvent extraction/evaporation technique followed by casting of the cake into rods in a heated surface. XRD patterns showed that cyclosporine-A was completely incorporated into PLGA. FTIR and DSC results indicated alterations on drug molecular conformation aiming to reach the most stable thermodynamic conformation at polymer/drug interface. Implants provided controlled/sustained in vitro release of the drug. During the first 7 weeks, the drug release was controlled by the diffusion of the cyclosporine-A; and between 7-23 week period, the drug diffusion and degradation of PLGA controlled the drug release.