14 resultados para Interobserver

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess interobserver agreement of ultrasound parameters for portal hypertension in hepatosplenic mansonic schistosomiasis. Spleen size, diameter of the portal, splenic and superior mesenteric veins and presence of thrombosis and cavernous transformation were determined by three radiologists in blinded and independent fashion in 30 patients. Interobserver agreement was measured by the kappa index and intraclass correlation coefficient. Interobserver agreement was considered substantial (κ = 0.714-0.795) for portal vein thrombosis and perfect (κ = 1) for cavernous transformation. Interobserver agreement measured by the intraclass correlation coefficient was excellent for longitudinal diameter of the spleen (r = 0.828-0.869) and splenic index (r = 0.816-0.905) and varied from fair to almost perfect for diameter of the portal (r = 0.622-0.675), splenic (r = 0.573-0.913) and superior mesenteric (r = 0.525-0.607) veins. According to the results, ultrasound is a highly reproducible method for the main morphological parameters of portal hypertension in schistosomiasis patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate intra- and interobserver agreement in the identification of incidental enchondromas at knee magnetic resonance imaging, and to assess the prevalence of imaging findings. Materials and Methods Retrospective study reviewing 326 knee magnetic resonance images acquired in the period between November 2009 and September 2010. The images were independently and blindly analyzed by two specialists in musculoskeletal radiology, with the objective of identifying incidental enchondromas, presence of foci with signal similar to bone marrow and foci of signal absence suggestive of calcifications within the enchondromas. Inter- and intraobserver agreements were analyzed. Results Eleven lesions compatible with enchondromas (3.3%) were identified. The interobserver agreement for the presence of enchondroma was high. Prevalence of foci of bone marrow signal inside the enchondromas was of 54.55%, and foci suggestive of calcification corresponded to 36.36%. The intraobserver agreement for foci of bone marrow signal in enchondromas was perfect, and interobserver agreement was high. Conclusion The prevalence of incidental enchondromas in the current study was compatible with data in the literature. Excellent agreement was observed in the identification of enchondromas and in the assessment of imaging findings. A higher prevalence of fat signal foci was observed as compared with signal absence suggestive of calcifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine anatomical and functional pelvic floor measurements performed with three-dimensional (3-D) endovaginal ultrasonography in asymptomatic nulliparous women without dysfunctions detected in previous dynamic 3-D anorectal ultrasonography (echo defecography) and to demonstrate the interobserver reliability of these measurements. METHODS: Asymptomatic nulliparous volunteers were submitted to echo defecography to identify dynamic dysfunctions, including anatomical (rectocele, intussusceptions, entero/sigmoidocele and perineal descent) and functional changes (non-relaxation or paradoxical contraction of the puborectalis muscle) in the posterior compartment and assessed with regard to the biometric index of levator hiatus, pubovisceral muscle thickness, urethral length, anorectal angle, anorectal junction position and bladder neck position with the 3-D endovaginal ultrasonography. All measurements were compared at rest and during the Valsalva maneuver, and perineal and bladder neck descent was determined. The level of interobserver agreement was evaluated for all measurements. RESULTS: A total of 34 volunteers were assessed by echo defecography and by 3-D endovaginal ultrasonography. Out of these, 20 subjects met the inclusion criteria. The 14 excluded subjects were found to have posterior dynamic dysfunctions. During the Valsalva maneuver, the hiatal area was significantly larger, the urethra was significantly shorter and the anorectal angle was greater. Measurements at rest and during the Valsalva maneuver differed significantly with regard to anorectal junction and bladder neck position. The mean values for normal perineal descent and bladder neck descent were 0.6 cm and 0.5 cm above the symphysis pubis, respectively. The intraclass correlation coefficient ranged from 0.62-0.93. CONCLUSIONS: Functional biometric indexes, normal perineal descent and bladder neck descent values were determined for young asymptomatic nulliparous women with the 3-D endovaginal ultrasonography. The method was found to be reliable to measure pelvic floor structures at rest and during Valsalva, and might therefore be suitable for identifying dysfunctions in symptomatic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial baroreflex sensitivity estimated by pharmacological impulse stimuli depends on intrinsic signal variability and usually a subjective choice of blood pressure (BP) and heart rate (HR) values. We propose a semi-automatic method to estimate cardiovascular reflex sensitivity to bolus infusions of phenylephrine and nitroprusside. Beat-to-beat BP and HR time series for male Wistar rats (N = 13) were obtained from the digitized signal (sample frequency = 2 kHz) and analyzed by the proposed method (PRM) developed in Matlab language. In the PRM, time series were low-pass filtered with zero-phase distortion (3rd order Butterworth used in the forward and reverse direction) and presented graphically, and parameters were selected interactively. Differences between basal mean values and peak BP (deltaBP) and HR (deltaHR) values after drug infusions were used to calculate baroreflex sensitivity indexes, defined as the deltaHR/deltaBP ratio. The PRM was compared to the method traditionally (TDM) employed by seven independent observers using files for reflex bradycardia (N = 43) and tachycardia (N = 61). Agreement was assessed by Bland and Altman plots. Dispersion among users, measured as the standard deviation, was higher for TDM for reflex bradycardia (0.60 ± 0.46 vs 0.21 ± 0.26 bpm/mmHg for PRM, P < 0.001) and tachycardia (0.83 ± 0.62 vs 0.28 ± 0.28 bpm/mmHg for PRM, P < 0.001). The advantage of the present method is related to its objectivity, since the routine automatically calculates the desired parameters according to previous software instructions. This is an objective, robust and easy-to-use tool for cardiovascular reflex studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Evaluation of inter and intraobserver reproducibility of by the visual method interpretation of cineangiogram in a clinically based context. METHODS: Five interventional cardiologists analyzed 11 segments of 8 coronary cineangiograms at a two month apart sessions. The percent luminal reduction by the lesions were analyzed by two different classifications: in one (A) the lesions were graded in 0% = absent, 1-50% = mild, 51 - 69 = moderate, and > or = 70% = severe; the other classification (B) was a dichotomic one : <70% = nonsignificant and > or = 70%=significant lesions. The agreement were measured by the kappa (k) index. RESULTS: Interobserver agreement was moderate for classification A (1st measurement, k = 0.36 -- 0.63, k m = 0.49; 2nd measurement, k = 0.39-0.68, k m = 0.52) and good for classification B (1st measurement, k = 0.55-0.73, k m = 0.63; 2nd measurement, k = 0.37-0.82, k m = 0.61). Intraobserver levels of agreement were k = 0.57-0.95 for classification A and 0.62-1.0 for classification B. CONCLUSION: The higher level of reproducibility obtained by adopting the dichotomous criteria usually considered for ischemic limits demonstrates that in the present clinical context, the reliability of the simple visual method is adequate for the identification of patients with clinically significant lesions and candidates for myocardial revascularization procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background: Studies have shown the impact of atrial fibrillation (AF) on the patients' quality of life. Specific questionnaires enable the evaluation of relevant events. We previously developed a questionnaire to assess the quality of life of patients with AF (AFQLQ version 1), which was reviewed in this study, and new domains were added. Objective: To demonstrate the reproducibility of the AFQLQ version 2 (AFQLQ v.2), which included the domains of fatigue, illness perception and well-being. Methods: We applied 160 questionnaires (AFQLQ v.2 and SF-36) to 40 patients, at baseline and 15 days after, to measure inter- and intraobserver reproducibility. The analysis of quality of life stability was determined by test-retest, applying the Bartko intraclass correlation coefficient (ICC). Internal consistency was assessed by Cronbach's alpha test. Results: The total score of the test-retest (n = 40) had an ICC of 0.98 in the AFQLQ v.2, and of 0.94 in the SF36. In assessing the intra- and interobserver reproducibility of the AFQLQ v.2, the ICC reliability was 0.98 and 0.97, respectively. The internal consistency had a Cronbach's alpha coefficient of 0.82, compatible with good agreement of the AFQLQ v.2. Conclusion: The AFQLQ v.2 performed better than its previous version. Similarly, the domains added contributed to make it more comprehensive and robust to assess the quality of life of patients with AF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To determine the presence of linear relationship between renal cortical thickness, bipolar length, and parenchymal thickness in chronic kidney disease patients presenting with different estimated glomerular filtration rates (GFRs) and to assess the reproducibility of these measurements using ultrasonography. Materials and Methods: Ultrasonography was performed in 54 chronic renal failure patients. The scans were performed by two independent and blinded radiologists. The estimated GFR was calculated using the Cockcroft-Gault equation. Interobserver agreement was calculated and a linear correlation coefficient (r) was determined in order to establish the relationship between the different renal measurements and estimated GFR. Results: The correlation between GFR and measurements of renal cortical thickness, bipolar length, and parenchymal thickness was, respectively, moderate (r = 0.478; p < 0.001), poor (r = 0.380; p = 0.004), and poor (r = 0.277; p = 0.116). The interobserver agreement was considered excellent (0.754) for measurements of cortical thickness and bipolar length (0.833), and satisfactory for parenchymal thickness (0.523). Conclusion: The interobserver reproducibility for renal measurements obtained was good. A moderate correlation was observed between estimated GFR and cortical thickness, but bipolar length and parenchymal thickness were poorly correlated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective:To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma.Materials and Methods:Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated.Results:The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers.Conclusion:64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Objective: To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. Materials and Methods: Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR technique, and then with a 3D TSE technique, both in the same 1.5 T MRI scanner. The patients underwent knee arthroscopy within the first three days after the MRI. Using arthroscopy as the reference standard, we determined the diagnostic performance and agreement. Results: For detecting anterior cruciate ligament tears, the 3D TSE and routine 2D TSE techniques showed similar values for sensitivity (93% and 93%, respectively) and specificity (80% and 85%, respectively). For detecting medial meniscal tears, the two techniques also had similar sensitivity (85% and 83%, respectively) and specificity (68% and 71%, respectively). In addition, for detecting lateral meniscal tears, the two techniques had similar sensitivity (58% and 54%, respectively) and specificity (82% and 92%, respectively). There was a substantial to almost perfect intraobserver and interobserver agreement when comparing the readings for both techniques. Conclusion: The 3D TSE technique has a diagnostic performance similar to that of the routine 2D TSE protocol for detecting meniscal and anterior cruciate ligament tears at 1.5 T, with the advantage of faster acquisition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To evaluate the precision of both two- and three-dimensional ultrasonography in determining vertebral lesion level (the first open vertebra) in patients with spina bifida. Methods This was a prospective longitudinal study comprising of fetuses with open spina bifida who were treated in the fetal medicine division of the department of obstetrics of Hospital das Clínicas of the Universidade de São Paulo between 2004 and 2013. Vertebral lesion level was established by using both two- and three-dimensional ultrasonography in 50 fetuses (two examiners in each method). The lesion level in the neonatal period was established by radiological assessment of the spine. All pregnancies were followed in our hospital prenatally, and delivery was scheduled to allow immediate postnatal surgical correction. Results Two-dimensional sonography precisely estimated the spina bifida level in 53% of the cases. The estimate error was within one vertebra in 80% of the cases, in up to two vertebrae in 89%, and in up to three vertebrae in 100%, showing a good interobserver agreement. Three-dimensional ultrasonography precisely estimated the lesion level in 50% of the cases. The estimate error was within one vertebra in 82% of the cases, in up to two vertebrae in 90%, and in up to three vertebrae in 100%, also showing good interobserver agreement. Whenever an estimate error was observed, both two- and three-dimensional ultrasonography scans tended to underestimate the true lesion level (55.3% and 62% of the cases, respectively). Conclusions No relevant difference in diagnostic performance was observed between the two- and three-dimensional ultrasonography. The use of three-dimensional ultrasonography showed no additional benefit in diagnosing the lesion level in the fetuses with spina bifida. Errors in both methods showed a tendency to underestimate lesion level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the present study was to translate the Roland-Morris (RM) questionnaire into Brazilian-Portuguese and adapt and validate it. First 3 English teachers independently translated the original questionnaire into Brazilian-Portuguese and a consensus version was generated. Later, 3 other translators, blind to the original questionnaire, performed a back translation. This version was then compared with the original English questionnaire. Discrepancies were discussed and solved by a panel of 3 rheumatologists and the final Brazilian version was established (Brazil-RM). This version was then pretested on 30 chronic low back pain patients consecutively selected from the spine disorders outpatient clinic. In addition to the traditional clinical outcome measures, the Brazil-RM, a 6-point pain scale (from no pain to unbearable pain), and its numerical pain rating scale (PS) (0 to 5) and a visual analog scale (VAS) (0 to 10) were administered twice by one interviewer (1 week apart) and once by one independent interviewer. Spearman's correlation coefficient (SCC) and intraclass correlation coefficient (ICC) were computed to assess test-retest and interobserver reliability. Cross-sectional construct validity was evaluated using the SCC. In the pretesting session, all questions were well understood by the patients. The mean time of questionnaire administration was 4 min and 53 s. The SCC and ICC were 0.88 (P<0.01) and 0.94, respectively, for the test-retest reliability and 0.86 (P<0.01) and 0.95, respectively, for interobserver reliability. The correlation coefficient was 0.80 (P<0.01) between the PS and Brazil-RM score and 0.79 (P<0.01) between the VAS and Brazil-RM score. We conclude that the Brazil-RM was successfully translated and adapted for application to Brazilian patients, with satisfactory reliability and cross-sectional construct validity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the present study was to translate and adapt the Berg balance scale, an instrument for functional balance assessment, to Brazilian-Portuguese and to determine the reliability of scores obtained with the Brazilian adaptation. Two persons proficient in English independently translated the original scale into Brazilian-Portuguese and a consensus version was generated. Two translators performed a back translation. Discrepancies were discussed and solved by a panel. Forty patients older than 65 years and 40 therapists were included in the cultural adaptation phase. If more than 15% of therapists or patients reported difficulty in understanding an item, that item was reformulated and reapplied. The final Brazilian version was then tested on 36 elderly patients (over age 65). The average age was 72 years. Reliability of the measure was assessed twice by one physical therapist (1-week interval between assessments) and once by one independent physical therapist. Descriptive analysis was used to characterize the patients. The intraclass correlation coefficient (ICC) and Pearson's correlation coefficient were computed to assess intra- and interobserver reliability. Six questions were modified during the translation stage and cultural adaptation phase. The ICC for intra- and interobserver reliability was 0.99 (P < 0.001) and 0.98 (P < 0.001), respectively. The Pearson correlation coefficient for intra- and interobserver reliability was 0.98 (P < 0.001) and 0.97 (P < 0.001), respectively. We conclude that the Brazilian version of the Berg balance scale is a reliable instrument to be used in balance assessment of elderly Brazilian patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present study was to translate, adapt and validate a Brazilian Portuguese version of the Disabilities of the Arm, Shoulder and Hand (DASH) Questionnaire. The study was carried out in two steps. The first was to translate the DASH into Portuguese and to perform cultural adaptation and the second involved the determination of the reliability and validity of the DASH for the Brazilian population. For this purpose, 65 rheumatoid arthritis patients of either sex (according to the classification criteria of the American College of Rheumatology), ranging in age from 18 to 60 years and presenting no other diseases involving the upper limbs, were interviewed. The patients were selected consecutively at the rheumatology outpatient clinic of UNIFESP. The following results were obtained: in the first step (translation and cultural adaptation), all patients answered the questions. In the second step, Spearman's correlation coefficients for interobserver evaluation ranged from 0.762 to 0.995, values considered to be highly reliable. In addition, intraclass correlation coefficients ranged from 0.97 to 0.99, also highly reliable values. Spearman's correlation coefficients and the intraclass correlation coefficients obtained during intra-observer evaluation ranged from 0.731 to 0.937 and from 0.90 to 0.96, respectively, being highly reliable values. The Ritchie Index showed a weak correlation with Brazilian DASH scores, while the visual analog scale of pain showed a good correlation with DASH score. We conclude that the Portuguese version of the DASH is a reliable instrument.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Animal models of intervertebral disc degeneration play an important role in clarifying the physiopathological mechanisms and testing novel therapeutic strategies. The objective of the present study is to describe a simple animal model of disc degeneration involving Wistar rats to be used for research studies. Disc degeneration was confirmed and classified by radiography, magnetic resonance and histological evaluation. Adult male Wistar rats were anesthetized and submitted to percutaneous disc puncture with a 20-gauge needle on levels 6-7 and 8-9 of the coccygeal vertebrae. The needle was inserted into the discs guided by fluoroscopy and its tip was positioned crossing the nucleus pulposus up to the contralateral annulus fibrosus, rotated 360° twice, and held for 30 s. To grade the severity of intervertebral disc degeneration, we measured the intervertebral disc height from radiographic images 7 and 30 days after the injury, and the signal intensity T2-weighted magnetic resonance imaging. Histological analysis was performed with hematoxylin-eosin and collagen fiber orientation using picrosirius red staining and polarized light microscopy. Imaging and histological score analyses revealed significant disc degeneration both 7 and 30 days after the lesion, without deaths or systemic complications. Interobserver histological evaluation showed significant agreement. There was a significant positive correlation between histological score and intervertebral disc height 7 and 30 days after the lesion. We conclude that the tail disc puncture method using Wistar rats is a simple, cost-effective and reproducible model for inducing disc degeneration.