75 resultados para Internal standardization

em Scielo Saúde Pública - SP


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Traditionally, in the cigarettes industry, the determination of ammonium ion in the mainstream smoke is performed by ion chromatography. This work studies this determination and compares the results of this technique with the use of external and internal standard calibration. A reference cigarette sample presented measurement uncertainty of 2.0 μg/cigarette and 1.5 μg/cigarette, with external and internal standard, respectively. It is observed that the greatest source of uncertainty is the bias correction factor and that it is even more significant when using external standard, confirming thus the importance of internal standardization for this correction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes a review on internal standardization in atomic absorption spectrometry with emphasis to the systematic and random errors in atomic absorption spectrometry and applications of internal standardization in flame atomic absorption spectrometry and electrothermal atomic absorption spectrometry. The rules for selecting an element as internal standard, limitations of the method, and some comments about the application of internal standardization in atomic absorption spectrometry and the future of this compensation strategy are critically discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The analysis of fatty acid (FA) esters by gas chromatography and flame ionization detector (FID) normally uses the normalization method. However, if one FA is wrongly estimated, the results could be greatly affected. In this study, methodologies using internal standards and correction factors for the FID response are described. The results show that by using theoretical correction factors associated to the internal standardization, the quantitative analyses of the FAs are expressed in mass, increasing the accuracy and facilitating the interpretation and comparison of the results for foods and biodiesels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A complete analysis of oils and their fractions allows correlations to be defined between their composition and derivatives or related geological materials. This work focused on optimization and implementation of a method for separation and quantification of n-alkanes in Brazilian oil samples by urea adduction and GC-FID techniques. Ten samples with different ºAPI were analyzed in triplicate to quantify individual n-alkanes and cyclic/branched alkane fraction. For individual quantification of n-alkanes, internal standardization with deuterated n-tetracosane was used. The use of urea adduction for the separation and quantification of n-alkanes was highly effective, with recovery values of above 80%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coffee cultivation via central-pivot fertigation can lead to fertilizer losses by soil profile internal drainage when water application is excessive and soils have low water retention and cation adsorption capacities. This study analyses the deep water losses from the top 1 m sandy soil layer of east Bahia, Brazil, cultivated with coffee at a high technology level (central-pivot fertigation), using above normal N fertilizer rates. The deep drainage (Q) estimation is made through the application of a climatologic water balance (CWB) program having as input direct measures of irrigation and rainfall, climatological data from weather stations, and measured soil water retention characteristics. The aim of the study is to contribute to the understanding of the hydric regime of coffee crops managed by central-pivot irrigation, analyzing three scenarios (Sc): i) rainfall only, ii) rainfall and irrigation full year, and iii) rainfall and irrigation dry season only. Annual Q values for the 2008/2009 agricultural year were: Sc i = 811.5 mm; Sc ii = 1010.5 mm; and Sc iii = 873.1 mm, so that the irrigation interruption in the wet season reduced Q by 15.7%, without the appearance of water deficit periods. Results show that the use of the CWB program is a convenient tool for the evaluation of Q under the cited conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To assess the internal consistency of the measurements of the Self-Reporting Questionnaire (SRQ-20) in different occupational groups. METHODS A validation study was conducted with data from four surveys with groups of workers, using similar methods. A total of 9,959 workers were studied. In all surveys, the common mental disorders were assessed via SRQ-20. The internal consistency considered the items belonging to dimensions extracted by tetrachoric factor analysis for each study. Item homogeneity assessment compared estimates of Cronbach’s alpha (KD-20), the alpha applied to a tetrachoric correlation matrix and stratified Cronbach’s alpha. RESULTS The SRQ-20 dimensions showed adequate values, considering the reference parameters. The internal consistency of the instrument items, assessed by stratified Cronbach’s alpha, was high (> 0.80) in the four studies. CONCLUSIONS The SRQ-20 showed good internal consistency in the professional categories evaluated. However, there is still a need for studies using alternative methods and additional information able to refine the accuracy of latent variable measurement instruments, as in the case of common mental disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A passive haemagglutination test (PHA) for human neurocysticercosis was standardized and evaluated for the detection of specific antibodies to Cysticercus cellulosae in cerebrospinal fluid (CSF). For the assay, formaldehyde-treated group O Rh-human red cells coated with the cysticerci crude total saline extract (TS) antigen were employed. A total of 115 CSF samples from patients with neurocysticercosis was analysed, of these 94 presented reactivity, corresponding to 81.7% sensitivity, in which confidence limit of 95% probability (CL95%) ranged from 74.5% to 88.9%. Eighty-nine CSF samples derived from individuals of control group presented as nonreactive in 94.4% (CL95% from 89.6% to 99.2%). The positive and negative predictive values were 1.4% and 99.9%, respectively, considering the mean rate of that this assay provide a rapid, highly reproducible, and moderately sensitive mean of detecting specific antibodies in CSF samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A radioactive Western-blotting technique was developed by which the reactivity of Immunoglobulins (Igs) from different classes to both membrane radiolabelled and internal parasite antigens is simultaneously identified. The method includes radioiodination of parasites, polypeptide fractionation by SDS-PAGE, Western-blot transfer and autoradiography of the immunoblots developed with anti-Igs conjugates labelled with enzymes. The analysis is then performed by the comparison of common bands on the autoradiograms and the respective substrate stained nitrocellulose blots. This technique was used to analyse T. cruzi trypomastigote surface labelled antigens reactive to IgM, IgA and IgG specific antibodies. A different pattern of reactivity with acute Chagas' disease patients sera was thus obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dot-enzyme-linked immunosorbent assay (dot-ELISA) was standardized using somatic (S) and excretory-secretory (ES) antigens of Toxocara-canis for the detection of specific antibodies in 22 serum samples from children aged 1 to 15 years, with clinical signs of toxocariasis. Fourteen serum samples from apparently normal individuals and 28 sera from patients with other pathologies were used as controls. All samples were used before and after absorption with Ascaris suum extract. When the results were evaluated in comparison with ELISA, the two tests were found to have similar sensitivity, but dot-ELISA was found to be more specific in the presence of the two antigens studied. Dot-ELISA proved to be effective for the diagnosis of human toxocariasis, presenting advantages in terms of yield, stability, time and ease of execution and low cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Dot-ELISA using a measles virus (MV) antigen obtained by sodium deoxycholate treatment was standardized and evaluated for IgM and IgG antibody detection in measles patients and measles-vaccinated subjects. A total of 192 serum samples were studied, comprising 47 from patients with acute and convalescent measles, 55 from 9-month old children prior to measles vaccination and 41 from children of the same age after vaccination, and 49 from patients with unrelated diseases. The diagnostic performances of the IgG Dot-ELISA and IgG immuno fluorescence test (IFT) were found to be close, varying from 0.97 to 1.00 in sensitivity and the specificities were maximum (1.00). Nevertheless, the sensitivity of the IgM Dot-ELISA (0.85) was higher than that (0.63) of the IgM IFT, although both assays had comparably high (1.00) specificities. The IgM Dot-ELISA in particular proved to be more sensitive in relation to other assays studied by revealing antibodies in 80.0% (12/15) of vaccinated children on the 15th day after immunization. In contrast the IgM IFT, failed to detect antibodies in the same group of vaccinated children. The stability of the MV antigen was longer than that of the IFT antigen, and the reproducibility of the Dot-Elisa was satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sensitivity and specificity of an enzyme-linked immunosorbent assay (ELISA) for the detection of circulating antigens from toxic components of Tityus serrulatus scorpion venom was determined in patients stung by T. serrulatus before antivenom administration. Thirty-seven patients were classified as mild cases and 19 as moderate or severe cases. The control absorbance in the venom assay was provided by serum samples from 100 individuals of same socioeconomic group and geographical area who had never been stung by scorpions or treated with horse antisera. The negative cutoff value (mean + 2 SD) corresponded to a venom concentration of 4.8 ng/ml. Three out of the 100 normal sera were positive, resulting in a specificity of 97%. The sensitivity of the ELISA when all cases of scorpion sting were included was 39.3%. When mild cases were excluded, the sensitivity increased to 94.7%. This study showed that this ELISA can be used for the detection of circulating venom toxic antigens in patients with systemic manifestations following. T. serrulatus sting but cannot be used for clinical studies in mild cases of envenoming since the test does not discriminate mild cases from control patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study is to standardize the technical variables for preparation and storage of Plasmodium falciparum and of antigen components extracted with the amphoteric detergent Zwittergent. P. falciparum obtained from in vitro culture was stored at different temperatures and for different periods of time. For each variable, antigen components of the parasite were extracted in the presence or absence of protease inhibitors and submitted or not to later dialysis. Products were stored for 15, 30 and 60 days at different temperatures and immunological activity of each extract was determined by SDS-PAGE and ELISA using positive or negative standard sera for the presence of IgG directed to blood stage antigens of P. falciparum. Antigen extracts obtained from parasites stored at -20oC up to 10 days or at -70oC for 2 months presented the best results, showing well-defined bands on SDS-PAGE and Western blots and presenting absorbance values in ELISA that permitted safe differentiation between positive and negative sera.