17 resultados para Industries -- Energy consumption

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy consumption in the world has been growing every year. The industrial sector represents 27.32% of the world energy demand. Heating systems that use solar energy may contribute with a percentage of the total energy required by industries. This work aimed to study the use of vacuum solar collectors for water pre-heating in boilers. We used four collectors installed according to NBR 15,569; water flow through the tubes was 0.058 L/s, and temperature in the inlet and outlet pipes was measured. Results showed that instantaneous radiation, and inlet fluid and room temperatures are variables that influence the process, reaching water maximum temperature in the solar collector outlet of 97.9 °C, and efficiency of approximately 65% for most experiments. For the financial viability evaluation, the payback study was applied, which resulted in 4; 7 and 5 years, for the respective sources: firewood, LPG (liquefied petroleum gas), and electricity. Regarding the calculation of the annual contribution to the reduction of greenhouse gases, it was, respectively, 2.162 and 356 kg of CO2 per m² of collector tubes, in comparison with firewood and LPG.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Abstract The present study aimed at investigating the influences of drying air temperature and flow rate on energy parameters and dehydration behaviour of apple slices. For this purpose, apple slices were dried in a convective dryer at air temperatures of 50, 60 and 70 °C, and air velocities of 1, 1.5 and 2 m s–1. Dehydration rate increased as the air temperature and flow rate increased from 50 to 70 °C and 1 to 2 m s–1, respectively. The effective moisture diffusivity was determined to be in the range of 6.75×10–10-1.28×10–9 m2 s–1. Results of data analysis showed that the maximum energy consumption (23.94 kW h) belonged to 50 °C and 2 m s–1 and the minimum (13.89 kW h) belonged to 70 °C and 1 m s–1 treatment. Energy efficiency values were in the range of 2.87-9.11%. Moreover, the results indicated that any increment in the air temperature increases thermal and drying efficiencies while any increment in the air flow rate decreases both of them.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To assess the association between dietary intake and central obesity among people living with HIV/AIDS and receiving highly active antiretroviral therapy. METHODS: A cross-sectional study was conducted involving 223 adult individuals in the city of São Paulo city in 2002. The study population was classified according to central obesity, defined as waist-to-hip ratio >0.95 for men and >0.85 for women. The dietary variables studied were energy consumption (in calories and calories/kilo of body weight), macronutrients (in grams and % of energy intake), total fiber (grams) and fruit and vegetables intake (grams). The potential confounders examined were sex, skin color, age, schooling, income, body mass index, physical activity, smoking habits, peripheral CD4+ T lymphocyte count and length of protease inhibitor use. The multiple logistic regression model was performed in order to evaluate the association between central obesity and dietary intake. RESULTS: The prevalence of central obesity was 45.7% and it was associated with greater consumption of lipids: for every increase of 10g of lipid intake the odds of central obesity increased 1.28 times. Carbohydrate consumption showed negative association (OR=0.93) with central obesity after adjustment for control variables. CONCLUSIONS: The results suggest that the amount of carbohydrates and lipids in the diet, regardless of total energy intake, may modify the chance of developing central obesity in the studied population. Nutritional interventions may be beneficial for preventing central obesity among HIV/AIDS patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE To assess the impact of consuming ultra-processed foods on the nutritional dietary profile in Brazil.METHODS Cross-sectional study conducted with data from the module on individual food consumption from the 2008-2009 Pesquisa de Orçamentos Familiares (POF – Brazilian Family Budgets Survey). The sample, which represented the section of the Brazilian population aged 10 years or over, involved 32,898 individuals. Food consumption was evaluated by two 24-hour food records. The consumed food items were classified into three groups: natural or minimally processed, including culinary preparations with these foods used as a base; processed; and ultra-processed.RESULTS The average daily energy consumption per capita was 1,866 kcal, with 69.5% being provided by natural or minimally processed foods, 9.0% by processed foods and 21.5% by ultra-processed food. The nutritional profile of the fraction of ultra-processed food consumption showed higher energy density, higher overall fat content, higher saturated and trans fat, higher levels of free sugar and less fiber, protein, sodium and potassium, when compared to the fraction of consumption related to natural or minimally processed foods. Ultra-processed foods presented generally unfavorable characteristics when compared to processed foods. Greater inclusion of ultra-processed foods in the diet resulted in a general deterioration in the dietary nutritional profile. The indicators of the nutritional dietary profile of Brazilians who consumed less ultra-processed foods, with the exception of sodium, are the stratum of the population closer to international recommendations for a healthy diet.CONCLUSIONS The results from this study highlight the damage to health that is arising based on the observed trend in Brazil of replacing traditional meals, based on natural or minimally processed foods, with ultra-processed foods. These results also support the recommendation of avoiding the consumption of these kinds of foods.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Our objective was to compare food intake and nutritional status of Pemphigus Foliaceus patients (PG) on long term glucocorticoid therapy to a Control Group (CG). Fourteen PG female inpatients receiving prednisone (0.33 ± 0.22mg/kg) for at least 12 months and twelve CG subjects were submitted to nutritional evaluation, including anthropometry, urinary creatinine determination and serum biochemical measurements, besides 48-h-based food intake records. Groups were compared by Chi-square, Mann-Whitney and "t" tests. PG patients and CG were paired, respectively, in relation to age (24.7 ± 14.1 vs. 22.0 ± 12.0 years), body mass index (25.8 ± 6.4 vs. 24.0 ± 5.6kg/m2), daily protein intake (132.9 ± 49.8 vs. 95.2 ± 58.9g), and serum albumin (median; range) (3.8; 3.5-4.1 vs. 3.8; 3.6-5.0g/dl). However, PG patients had lower height-creatinine index (64.8 ± 17.6 vs. 90.1 ± 33.4%), and higher daily energy (3080 ± 1099 vs. 2187 ± 702kcal) and carbohydrate (376.8 ± 135.8 vs. 242.0 ± 80.7g) intakes. Despite high food, protein and energy consumption, PG patients on long term glucocorticoid therapy had lower body muscle mass than controls, while showing high body fat stores. These findings are possibly related to combined metabolic effects of long term corticotherapy and inflammatory disease plus corticosteroid-induced increased appetite.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this work is to establish a program for the treatment of chemical residues and waste waters at the Centro de Energia Nuclear na Agricultura (CENA/USP), for environmental preservation and training of staff. Five tons of stored residues and the ones currently generated in the laboratories have to be treated. Rational use of water is also part of the program. The traditional purification by distillation has been replaced by purification with ion exchange resins. Lower energy consumption and better water quality were achieved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biomass was the dominating source of energy for human activities until the middle 19th century, when coal, oil, gas and other energy sources became increasingly important but it still represents ca. 10% of the worldwide energy supply. The major part of biomass for energy is still "traditional biomass" used as wood and coal extracted from native forests and thus non-sustainable, used with low efficiency for cooking and home heating, causing pollution problems. This use is largely done in rural areas and it is usually not supported by trading activities. There is now a strong trend to the modernization of biomass use, especially making alcohol from sugar cane thus replacing gasoline, or biodiesel to replace Diesel oil, beyond the production of electricity and vegetable coal using wood from planted forests. As recently as in 2004, sustainable "modern biomass" represented 2% of worldwide energy consumption. This article discusses the perspectives of the "first" and "second" technology generations for liquid fuel production, as well as biomass gaseification to make electricity or syngas that is in turn used in the Fischer-Tropsch process.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Water electrolysis is one of the simplest methods used for hydrogen production. It has the advantage of being able to produce hydrogen using only renewable energy. To expand the use of water electrolysis, it is mandatory to reduce energy consumption, cost, and maintenance of current electrolyzers, and, on the other hand, to increase their efficiency, durability, and safety. In this study, modern technologies for hydrogen production by water electrolysis have been investigated. In this article, the electrochemical fundamentals of alkaline water electrolysis are explained and the main process constraints (e.g., electrical, reaction, and transport) are analyzed. The historical background of water electrolysis is described, different technologies are compared, and main research needs for the development of water electrolysis technologies are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, we describe the development of low-cost teaching experiments of electrogravimetry for undergraduate students using principles of green chemistry. Copper was electrochemically deposited on brass under an electrical current density of 50 mA cm−2 from acidic solutions containing nitrate anions. Color changes at the brass electrode and of the solution were observed, indicating that the reduction of copper ions had occurred. The deposition efficiency values were between 92.8% and 93.8%, and the electrochemical efficiency values were between 85.6% and 86.5%. There was no significant contribution from parallel reactions. These experimental conditions facilitated the didactic exploration of gravimetric and electrochemical concepts. Following the principles of green chemistry, the experiments produced no toxic substances, all the materials could be recycled, and the energy consumption was the lowest. For this reason, this experiment was considered to be very interesting for didactical purposes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work is a study of the implementation of a classical controller using a tuning method referred to as IMC (Internal Model Control) and aimed at the reduction of electrical energy consumption by the appropriate relation between energy consumption and the cooling time with forced air. The supervisory system installed was able to manipulate the variable of frequency of the signal power of the exhaust fan engine (forced air module), to accelerate or decelerate the loss of heat from the product to be cooled by airflow variation that passes through the mass of the produce. The results demonstrated a reduction in energy consumption from 64% and an increase of only 8% in the cooling time to the system using PI/IMC (Proportional - Integral with IMC) tuning method compared with the system in its operating nominal condition. This PI/IMC control may be implemented directly in a frequency converter, without the need to purchase a computer or PLC (programmable logic controller) to run the dedicated application, increasing its economical viability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The type of artificial light used for inducing photoperiod effect in begonia's seedlings at greenhouse has fundamental importance in the growth and development of these plants and directly reflects in the electrical energy consumption used in this production process. The objective of this research was to analyze the technical and economic feasibility of replacing the current technology of artificial lighting used by the producers (incandescent lamps), by the technology of discharge lamps with the purpose of inducing photoperiod in a greenhouse. The analysis results indicate that the discharge lamp of 32 W Tubular Fluorescent discharge lamp was the one that presented the lower peak demand and lower average energy consumption of 85.01% compared to incandescent filament lamp of 100 W that is the technology of bigger consumption and currently used by the producer.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this work was to evaluate the energy flows of a commercial production system of swine deep bed in its finishing phase, located in Juiz de Fora, in the State of Minas Gerais, Brazil. Thus, an energy efficiency study was carried out by monitoring a lot of animals, during a 94-day period. The energy rate of each compound involved in the production process was quantified and the matrixes of energy consumption were determined in the form of animal feeding, electrical energy, piglets, material used as deep bed, human labor, equipment, swine buildings, production of alive swine for slaughter, organic fertilizer production (swine deep bed or swine deep litter). From the direct input energy, 80.57% correspond to animal feeding, 11.90% to pigs for slaughter and 6.76% to piglets, while from the energy output 53.45% correspond to the terminating swine and 46.55% to organic fertilizer (swine deep bed). By the results obtained, we can conclude that such production system has corresponded to an industrial and highly specialized agro ecosystem, importing a great part of the energy consumed in the production process, with 41% of energy efficiency.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study was conducted to evaluate and compare the behavior of the heating inside poultry shed through gas hood and underfloor heating. The experiment was conducted in poultry shed belonging to the Federal Institute of Education, Science and Technology of Triângulo Mineiro Region, Uberlândia city – state of Minas Gerais (MG), Brazil. The dimensions of the shed are 24 meters long and 9.6 meters wide and with a ceiling height of 3.2 meters. The temperature was measured with an optical thermometer of Minipa brand, MT 350 model. It was used, to the analysis of temperature behavior, the public domain software FEMM 4.2, which uses finite elements techniques, with data collected from two lots. Underfloor heating is made using hot water flowing through a serpentine type system, which is installed below the bed; this hot water is from solar heaters. An energetic and economic assessment of the warming shed for raising chickens was realized. From the results obtained with the simulations, it may observe that the heating through the floor provides a more homogeneous distribution of temperature when compared with the hood heating. The flow of heat is upwards supplying, thus, the greatest need of heating of the bird, which is the pectoral part.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hydrogen peroxide (H2O2) perfused into the aorta of the isolated rat heart induces a positive inotropic effect, with cardiac arrhythmia such as extrasystolic potentiation or cardiac contractures, depending on the dose. The last effect is similar to the "stone heart" observed in reperfusion injury and may be ascribed to lipoperoxidation (LPO) of the membrane lipids, to protein damage, to reduction of the ATP level, to enzymatic alterations and to cardioactive compounds liberated by LPO. These effects may result in calcium overload of the cardiac fibers and contracture ("stone heart"). Hearts from male Wistar rats (300-350 g) were perfused at 31oC with Tyrode, 0.2 mM trolox C, 256 mM H2O2 or trolox C + H2O2. Cardiac contractures (baseline elevation of the myograms obtained) were observed when hearts were perfused with H2O2 (Tyrode: 5.9 ± 3.2; H2O2: 60.5 ± 13.9% of the initial value); perfusion with H2O2 increased the LPO of rat heart homogenates measured by chemiluminescence (Tyrode: 3,199 ± 259; H2O2: 5,304 ± 133 cps mg protein-1 60 min-1), oxygen uptake (Tyrode: 0.44 ± 0.1; H2O2: 3.2 ± 0.8 nmol min-1 mg protein-1) and malonaldehyde (TBARS) formation (Tyrode: 0.12 ± 0; H2O2: 0.37 ± 0.1 nmol/ml). Previous perfusion with 0.2 mM trolox C reduced the LPO (chemiluminescence: 4,098 ± 531), oxygen uptake (0.51 ± 0) and TBARS (0.13 ± 0) but did not prevent the H2O2-induced contractures (33.3 ± 16%). ATP (Tyrode: 2.84 ± 0; H2O2: 0.57 ± 0) and glycogen levels (Tyrode: 0.46 ± 0; H2O2: 0.26 ± 0) were reduced by H2O2. Trolox did not prevent these effects (ATP: 0.84 ± 0 and glycogen: 0.27 ± 0). Trolox C is known to be more effective than -- $MVD$:face("Symbol") -->a -tocopherol or -- $MVD$:face("Symbol") -->g -tocopherol in reducing LPO though it lacks the phytol portion of vitamin E to be fixed to the cell membranes. Trolox C, unlike vitamin A, did not prevent the glycogen reduction induced by H2O2. Trolox C induced a positive chronotropic effect that resulted in higher energy consumption. The reduction of energy level seemed to be more important than LPO in the mechanism of H2O2-induced contracture

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In anurans, changes in ambient temperature influence body temperature and, therefore, energy consumption. These changes ultimately affect energy supply and, consequently, heart rate (HR). Typically, anurans living in different thermal environments have different thermal sensitivities, and these cannot be distinguished by changes in HR. We hypothesized that Rhinella jimi (a toad from a xeric environment that lives in a wide range of temperatures) would have a lower thermal sensitivity regarding cardiac control than R. icterica (originally from a tropical forest environment with a more restricted range of ambient temperatures). Thermal sensitivity was assessed by comparing animals housed at 15° and 25°C. Cardiac control was estimated by heart rate variability (HRV) and heart rate complexity (HRC). Differences in HRV between the two temperatures were not significant (P=0.214 for R. icterica and P=0.328 for R. jimi), whereas HRC differences were. All specimens but one R. jimi had a lower HRC at 15°C (all P<0.01). These results indicate that R. jimi has a lower thermal sensitivity and that cardiac control is not completely dependent on the thermal environment because HRC was not consistently different between temperatures in all R. jimi specimens. This result indicates a lack of evolutive trade-offs among temperatures given that heart rate control at 25°C is potentially not a constraint to heart rate control at 15°C.