42 resultados para Indoor pollutants

em Scielo Saúde Pública - SP


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atmospheric pollutants can have serious impacts on the preservation of São Paulo's tangible cultural heritage. The purpose of this paper is to report the results of a monitoring campaign focussed on particulate matter (PM) that was conducted in three of the most important museums of the São Paulo megacity (Brazil): the Museu de Arqueologia e Etnologia (MAE-USP), the Museu Paulista (MP-USP), and the Pinacoteca do Estado de São Paulo (PE). These museums exhibit indoor PM and black carbon (BC) concentrations consistent with their urban locations and their specific methods for managing the indoor environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Analisar o nível de ruído no ambiente de trabalho do professor de educação física durante as aulas de ciclismo indoor e sua associação com alguns aspectos da saúde. MÉTODOS: Estudo transversal conduzido com 15 professores de educação física de diferentes academias de ginástica, na cidade do Rio de Janeiro (RJ), em 2007. As características do processo e da organização do trabalho e as queixas de saúde relatadas pelos professores foram coletadas por meio de questionário padronizado. Para verificação dos transtornos psiquiátricos menores foi usado o SRQ-20 (Self-Report Questionnaire). As medidas de pressão sonora foram realizadas em um aparelho portátil. O nível de pressão foi medido em dB(A) no nível equivalente de energia em diferentes pontos da sala e momentos da aula. As análises estatísticas utilizadas foram a ANOVA, o qui-quadrado e a correlação de Pearson. RESULTADOS: Os níveis de pressão sonora variaram entre 74,4 dB(A) e 101,6 dB(A). Os valores médios encontrados durante as aulas foram: a) aquecimento (média= 88,45 dB(A)); b) parte principal (média= 95,86 dB(A)); e, fechamento (média= 85,12 dB(A)). O ruído de fundo apresentou o valor médio de 66,89 dB(A). Houve diferenças significativas (p<0,001) entre os valores médios de ruído de fundo e as fases da aula. O ruído não se correlacionou aos transtornos psiquiátricos menores. CONCLUSÕES: Os profissionais de educação física que trabalham com ciclismo indoor estão sujeitos a níveis elevados de pressão sonora em suas aulas. Este agente físico tem sido associado a diversos problemas de saúde e, portanto, requerer um controle mais amplo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: O ciclismo indoor é um exercício aeróbico no qual se utiliza grandes grupamentos musculares dos membros inferiores, carente de impacto osteoarticular e de elevado gasto calórico, o que o torna interessante para se gerar uma estratégia não farmacológica. OBJETIVO: Analisar a composição corporal e o perfil lipídico sérico de mulheres com sobrepeso após doze semanas de dieta hipocalórica e treinamento de ciclismo indoor. MÉTODOS: Foram randomizadas 40 mulheres (23,90 ± 3,10 anos), subdivididas em quatro grupos: controle (C), ciclismo indoor (CI), ciclismo indoor associado a dieta hipocalórica (CD) e dieta hipocalórica (D). As variáveis analisadas foram: estatura e massa corporal, IMC, percentual de gordura, massa magra, triglicerídeos, colesterol e lipoproteinas (HDL,LDL,VLDL). O treinamento de ciclismo indoor consistiu em três sessões semanais de 45 minutos cada e a uma restrição energética de aproximadamente 1.200 kcal. O estudo teve duração de 12 semanas. Utilizou-se a estatística descritiva (média e desvio padrão) e inferencial (test t de Student). O nível de significância adotado foi de p < 0,05. RESULTADOS: Os grupos CI, CD e D reduziram significativamente as médias das variáveis antropométricas após as 12 semanas de intervenção (massa corporal, percentual de gordura e índice de massa corporal), além dos níveis séricos de colesterol total e triglicerídios. Em relação ao HDL colesterol, houve aumento significativo para os grupos CI e CD. CONCLUSÃO: De acordo com os resultados, o ciclismo indoor e a dieta hipocalórica contribuíram no combate ao sobrepeso bem como no controle do nível sérico dos lipídeos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study it was compared the MAS-100 and the Andersen air samplers' performances and a similar trend in both instruments was observed. It was also evaluated the microbial contamination levels in 3060 samples of offices, hospitals, industries, and shopping centers, in the period of 1998 to 2002, in Rio de Janeiro city. Considering each environment, 94.3 to 99.4% of the samples were the allowed limit in Brazil (750 CFU/m³). The industries' results showed more important similarity among fungi and total heterotrophs distributions, with the majority of the results between zero and 100 CFU/m³. The offices' results showed dispersion around 300 CFU/m³. The hospitals' results presented the same trend, with an average of 200 CFU/m³. Shopping centers' environments showed an average of 300 CFU/m³ for fungi, but presented a larger dispersion pattern for the total heterotrophs, with the highest average (1000 CFU/m³). It was also investigated the correlation of the sampling period with the number of airborne microorganisms and with the environmental parameters (temperature and air humidity) through the principal components analysis. All indoor air samples distributions were very similar. The temperature and air humidity had no significant influence on the samples dispersion patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sterile insect technique (SIT) is a promising pest control method in terms of efficacy and environmental compatibility. In this study, we determined the efficacy of thiotepa-sterilised males in reducing the target Aedes aegypti populations. Treated male pupae were released weekly into large laboratory cages at a constant ratio of either 5:1 or 2:1 sterile-to-fertile males. A two-to-one release ratio reduced the hatch rate of eggs laid in the cage by approximately a third and reduced the adult catch rate by approximately a quarter, but a 5:1 release drove the population to elimination after 15 weeks of release. These results indicate that thiotepa exposure is an effective means of sterilising Ae. aegypti and males thus treated are able to reduce the reproductive capacity of a stable population under laboratory conditions. Further testing of the method in semi-field enclosures is required to evaluate the mating competitiveness of sterile males when exposed to natural environmental conditions. If proven effective, SIT using thiotepa-sterilised males may be incorporated into an integrated programme of vector control to combat dengue in Cuba.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preliminary study of insects associated to indoor body decay in Colombia. This is the first report studying insects associated to indoor body decay process of a white pig (Sus scrofa) (Artiodactyla, Suidae) in a controlled indoor environment in an urban area of Florencia city, Amazonia Piedmont, Colombia. For a period of 54 days, 9,220 individuals (immature and adults), distributed in 3 orders, 5 families, 10 genera, and 10 species were collected using entomological nets and tweezers. Five decaying stages are described (fresh, bloated, active decay, advanced decay and remains). During the fresh stage we recorded Cochliomyia macellaria (Fabricius, 1775), Chrysomya albiceps (Wiedemann, 1819), Ophyra aenescens (Wiedemann, 1830), Oxysarcodexia sp., Lepidodexia sp. and Lasiophanes sp.; during the bloating stage C. macellaria, C. albiceps, Lucilia eximia (Wiedemann, 1819), Hemilucillia semidiaphana (Rondani, 1850), Musca domestica Linnaeus, 1758, O. aenescens, Oxysarcodexia sp., Lepidodexia sp., Dermestes maculatus De Geer, 1774 and Lasiphanes sp.; during the active decay C. macellaria, C. albiceps, L. eximia, M. domestica, O. aenescens, Lepidodexia sp. D. maculatus and Lasiophanes sp.; during the advanced decay C. macellaria, C. albiceps, M. domestica, Lepidodexia sp. and Lasiophanes sp.; and during the remains stage C. albiceps, D. maculatus and Lasiophanes sp. The insects were sorted out in 3 ecological categories; necrophagous, predators and parasites and sarco-saprophagous. According to Chao and Jack estimators, total richness was observed on day 20, with 100% of the expected species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work compared the behaviour of pre-parturient sows housed in intensive confined and outdoor systems, during the morning and afternoon prior to delivery. Eight sows were kept individually in farrowing crates or in paddocks with access to fresh pasture from 8 to 10 days before expected parturition. All outdoor sows built a nest within 24 hours before farrowing. On the morning and afternoon before farrowing they spent 6.5% of the time collecting grass and 7.5% of the time organizing the nest. Outdoor sows were observed more often than confined sows rooting (4.60% vs. 0.25%), feeding (10.2% vs. 3.0%), standing (51% vs. 13%) and walking (8% vs. 0%). Indoor sows redirected the nesting behaviour to other behaviours like attempts to dig the ground, nosing, biting and rooting parts of the crate, feeder or drinker, during 4.7% of the time. They also spent more time than outdoor sows inactive (85% vs. 60%), lying (72% vs. 41%), drinking (2.1% vs. 0.5%) and vacuum chewing (3.7% vs. 0.1%). The pre-parturient behaviour of sows was considerably affected by the husbandry system. The outdoor system appears to be more appropriate for the sows' welfare than the conventional confinement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Brazil, very little experimental work on measurements of indoor air pollutant levels has been done. Nowadays, increasing attention is being given to indoor air quality and the health problems associated with buildings and the indoor work environment. The scope of this paper is to review the major pollutants found in indoor environments and their sources. Subsequently, exposure to indoor air pollutants and health effects are considered. The review concludes by briefly addressing assessment of indoor air quality in Brazil and research needs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sediment contamination is evaluated by determining organic micropollutants (organochlorine compounds - OCs and polycyclic aromatic hydrocarbons - PAHs) in two important Brazilian water reservoirs. Trace levels of OCs were observed in the Santana reservoir (44.8 ng g-1 d.w. of p,p'-DDT), while in the Funil reservoir the levels were below detection level. Forty-eight percent of the found sigmaocs were polychlorinated biphenyls, 29% dichlorodiphenyltrichloroethane (DDT), 18% Drins, and 5% other pesticides (HCB, Heptachlor, Heptachlor-epoxide, gamma-HCH and a-Endosulfan). We observed lower levels of sigmaPAH in the Funil reservoir (1 to 275 ng g-1d.w.) than in the Santana reservoir (2.2 to 26.7 µg g-1 d.w.).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new passive sampling system for monitoring NO2 in air has been developed to measure gas concentrations in indoor and outdoor air. The sampler is inexpensive, and easy to construct and operate. Nitrogen dioxide forms a derivative after reaction with a filter coated with triethanolamine and ethyleneglycol. The nitrogen dioxide derivative is extracted from the filter, and the concentration is determined by colorimetry. To test the sampler for measuring ambient level nitrogen dioxide, measurements were carried out inside homes and in a range of workplace environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study deals with phenol adsorption on chitin and chitosan and removal of contaminants from wastewater of a petroleum refinery. The adsorption kinetic data were best fitted to first- and second-order models for chitosan and chitin, respectively. The results of adsorption isotherms showed Langmuir model more appropriately described than a Freundlich model for both adsorbents. The adsorption capacity was 1.96 and 1.26 mg/g for chitin and chitosan, respectively. Maximum removal of phenol was about 70-80% (flow rate: 1.5 mL/min, bed height: 18.5 cm, and 30 mg/L of phenol. Wastewater treatment with chitin in a fixed-bed system showed reductions of about 52 and 92% for COD and oil and greases, and for chitosan 65 and 67%, respectively. The results show improvement of the effluent quality after treatment with chitin and chitosan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simultaneous measurements of outdoor and indoor pollution were performed at three schools in Lisbon. Volatile organic compounds (VOCs), formaldehyde and NO2 were passively monitored over a two-week period. Bacterial and fungal colony-forming units and comfort parameters were also monitored at classrooms and playgrounds. The highest indoor levels of CO2 (2666 μg/m³), NO2 (40.3 μg/m³), VOCs (10.3 μg/m³), formaldehyde (1.03 μg/m³) and bioaerosols (1634 CFU/m³), and some indoor/outdoor ratios greater than unity, suggest that indoor sources and building conditions might have negative effects on air indoors. Increasing ventilation rates and use of low-emission materials would contribute towards improving indoor air quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Information about capacity of transport and dispersion of soluble pollutants in natural streams are important in the management of water resources, especially in planning preventive measures to minimize the problems caused by accidental or intentional waste, in public health and economic activities that depend on the use of water. Considering this importance, this study aimed to develop a warning system for rivers, based on experimental techniques using tracers and analytical equations of one-dimensional transport of soluble pollutants conservative, to subsidizing the decision-making in the management of water resources. The system was development in JAVA programming language and MySQL database can predict the travel time of pollutants clouds from a point of eviction and graphically displays the temporal distribution of concentrations of passage clouds, in a particular location, downstream from the point of its launch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Atlantic Forest on the slopes of Serra do Mar around Cubatão (São Paulo, Brazil) has been affected by massive emissions of pollutants from the local growing industrial complex. The effects of air pollution on the amounts of leaf nitrogen, total soluble phenols and total tannins of Tibouchina pulchra Cogn., a common species in the area of Cubatão, were investigated, as well as the possible influence of the altered parameters on the leaf area damaged by herbivores. Fully expanded leaves were collected at two sites: the valley of Pilões river (VP), characterized by a vegetation virtually not affected by air pollution and taken as a reference; and valley of Mogi river (VM), close to the core region of the industrial complex, and severely affected by air pollution. No differences were observed for any parameters between samples collected in the summer and winter in both sites. On the other hand, compared to VP, individuals growing in VM presented higher amounts of nitrogen and lower amounts of total soluble phenols and total tannins, as well as higher percentages of galls per leaf and higher leaf area lost to herbivores. Regression analysis revealed that the increase in leaf area lost to herbivores can be explained by the increase of the content of nitrogen and decrease in the contents of total soluble phenols and total tannins. Although significant, the coefficients of explanation found were low for all analyses, suggesting that other biotic or abiotic factors are likely to influence leaf attack by herbivores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies of cooking-generated NO2 effects are rare in occupational epidemiology. In the present study, we evaluated the lung function of professional cooks exposed to NO2 in hospital kitchens. We performed spirometry in 37 cooks working in four hospital kitchens and estimated the predicted FVC, FEV1 and FEF25-75, based on age, sex, race, weight, and height, according to Knudson standards. NO2 measurements were obtained for 4 consecutive days during 4 different periods at 20-day intervals in each kitchen. Measurements were performed inside and outside the kitchens, simultaneously using Palm diffusion tubes. A time/exposure indicator was defined as representative of the cumulative exposure of each cook. No statistically significant effect of NO2 exposure on FVC was found. Each year of work as a cook corresponded to a decrease in predicted FEV1 of 2.5% (P = 0.046) for the group as a whole. When smoking status and asthma were included in the analysis the effect of time/exposure decreased about 10% and lost statistical significance. On predicted FEF25-75, a decrease of 3.5% (P = 0.035) was observed for the same group and the inclusion of controllers for smoking status and asthma did not affect the effects of time/exposure on pulmonary function parameter. After a 10-year period of work as cooks the participants of the study may present decreases in both predicted FEV1 and FEF25-75 that can reach 20 and 30%, respectively. The present study showed small but statistically significant adverse effects of gas stove exposure on the lung function of professional cooks.