90 resultados para Immuno-diagnostics
em Scielo Saúde Pública - SP
Resumo:
An immunoprecipitation technique, ELIEDA (enzyme-linked-immuno-electro-diffusion assay), was evaluated for the diagnosis of Schistosoma mansoni infection with low worm burden. One hundred of serum samples from patients excreting less than 600 eggs per gram of feces (epg), with unrelated diseases and clinically healthy subjects were studied. In patients with egg counts higher than 200 epg, the sensitivities of IgM and IgG ELIEDA were 1.000 and 0.923, respectively, not differing from other Serologic techniques, such as indirect hemaglutination (IHAT), immunofluorescence (IFT) tests and immuno-electrodiffusion assay (IEDA). However in patients with low egg counts (< 100 epg), the IgG ELIEDA provided better results (0.821) than IgM ELIEDA (0.679), showing sensitivity that did not differ from that of IgG IFT (0.929), but lower than that of IgM IFT (0.964). However, its sensivity was higher than that found with IHAT (0.607) and IEDA (0.536). The specificity of IgG ELIEDA was comparable to that of other techniques. The data indicate that IgG ELIEDA might be useful for the diagnosis of slight S. mansoni infections, and the cellulose acetate membrane strips can be stored for further retrospective studies.
Resumo:
Antibody in human sera that induces lysis of sheep erythrocytes in hemolytic assay was investigated. The present study showed that the presence in serum of the thermostable cytolytic anti-sheep red blood cells antibodies is dependent on the Schistosoma mansoni infection, and this is more frequent in adults than in children. The thermostable characteristic of hemolysins in normal sera was not dependent on the presence of Ascaris lumbricoides, Trichuris trichiura or hookworm geo-helminths. Further, thermostable complement-activating heterophile antibodies were noticed in children in association with massive number of S. mansoni eggs. The results were obtained by using the z- and the chi-square tests. The z-test allows us to formulate a one-sided alternative, i.e., a tendency of one of the attributes. On the other hand, the chi-square test analyzes the independence between attributes by using a contingency table. Besides the obtained results being interesting in the field of schistosomiasis mansoni, they can provide a new insight into the use of statistics in medical science.
Resumo:
Detection of rotavirus RNA by polyacrylamide gel electrophoresis (PAGE) proved to be a highly sensitive and rapid diagnostic test. A comparison of this assay with immuno-electron microscopy (IEM) and enzyme immunoassay (EIA) in 245 faeces from children with gastroenteritis revealed complete agreement between the three assays in 238 (97.14%) samples. Among 75 samples positive in at least one of the three assays, negative results were observed in 5 (6.48%) by PAGE, in 6 (6.76%) by EIA and in none by IEM. Silver staining greatly increased the sensitivity of the PAGE assay. We conclude that although IEM remains the most sensitive and rapid rotavirus diagnostic assay, the PAGE technique has many advantages in its favour, including the non-requirement of expensive equipment, the use of only chemically defined reagents and the capacity to distinguish virus subgroup and variants and to detect non-crossreactive rotaviruses which are missed in serological assays.
Resumo:
The levels of IgE and IgG4 increased strongly between cohorts, indicating a dynamic immunological situation, but no immediate impact on infection levels. Morbidity was little specific abdominal discomfort was reported by 61%, diarrhoea by 33% of the subjects; mild hepatomegaly was found in 16%, splenomegaly in 0.5%. No relation to egg counts was observed for any symptom. This mild morbidity may be due to the recent nature of the focus. In the first cohort, the percentage of people with negative egg counts ten weeks after treatment was only 18%, though egg counts declined strongly. Antigen detection confirmed these results. Praziquantel treatment provoked transient but impressive side effects (colics, vomiting, urticaria, aedema), the occurrence of which correlated with intensity of infection. Cure rates in subsequent cohorts were followed up shorter after treatment but remained low. Reinfection nevertheless oppears limited. This lower drug efficacy may be due to very rapid reinfection and/or to the lack of immunity in the population, but also reduced susceptibility of the local parasite strain must be considered and studied.
Resumo:
In the light of emerging and overlooked infectious diseases and widespread drug resistance, diagnostics have become increasingly important in supporting surveillance, disease control and outbreak management programs. In many low-income countries the diagnostic service has been a neglected part of health care, often lacking quantity and quality or even non-existing at all. High-income countries have exploited few of their advanced technical abilities for the much-needed development of low-cost, rapid diagnostic tests to improve the accuracy of diagnosis and accelerate the start of appropriate treatment. As is now also recognized by World Healt Organization, investment in the development of affordable diagnostic tools is urgently needed to further our ability to control a variety of diseases that form a major threat to humanity. The Royal Tropical Institute's Department of Biomedical Research aims to contribute to the health of people living in the tropics. To this end, its multidisciplinary group of experts focuses on the diagnosis of diseases that are major health problems in low-income countries. In partnership we develop, improve and evaluate simple and cheap diagnostic tests, and perform epidemiological studies. Moreover, we advice and support others - especially those in developing countries - in their efforts to diagnose infectious diseases.
Resumo:
This paper investigates defect detection methodologies for rolling element bearings through vibration analysis. Specifically, the utility of a new signal processing scheme combining the High Frequency Resonance Technique (HFRT) and Adaptive Line Enhancer (ALE) is investigated. The accelerometer is used to acquire data for this analysis, and experimental results have been obtained for outer race defects. Results show the potential effectiveness of the signal processing technique to determine both the severity and location of a defect. The HFRT utilizes the fact that much of the energy resulting from a defect impact manifests itself in the higher resonant frequencies of a system. Demodulation of these frequency bands through use of the envelope technique is then employed to gain further insight into the nature of the defect while further increasing the signal to noise ratio. If periodic, the defect frequency is then present in the spectra of the enveloped signal. The ALE is used to enhance the envelope spectrum by reducing the broadband noise. It provides an enhanced envelope spectrum with clear peaks at the harmonics of a characteristic defect frequency. It is implemented by using a delayed version of the signal and the signal itself to decorrelate the wideband noise. This noise is then rejected by the adaptive filter that is based upon the periodic information in the signal. Results have been obtained for outer race defects. They show the effectiveness of the methodology to determine both the severity and location of a defect. In two instances, a linear relationship between signal characteristics and defect size is indicated.
Resumo:
Three recombinant antigens of Treponema pallidum Nichols strain were fused with GST, cloned and expressed in Escherichia coli, resulting in high levels of GST-rTp47 and GST-rTp17 expression, and supplementation with arginine tRNA for the AGR codon was needed to obtain GST-rTp15 overexpression. Purified fusion protein yields were 1.9, 1.7 and 5.3 mg/l of cell culture for GST-rTp47, GST-rTp17 and GST-rTp15, respectively. The identities of the antigens obtained were confirmed by automated DNA sequencing using ABI Prism 310 and peptide mapping by Finningan LC/MS. These recombinant antigens were evaluated by immuno-slot blot techniques applied to 137 serum samples from patients with a clinical and laboratory diagnosis of syphilis (61 samples), from healthy blood donors (50 samples), individuals with sexually transmitted disease other than syphilis (3 samples), and from individuals with other spirochetal diseases such as Lyme disease (20 samples) and leptospirosis (3 samples). The assay had sensitivity of 95.1% (95% CI, 86.1 to 98.7%) and a specificity of 94.7% (95% CI, 87.0 to 98.7%); a stronger reactivity was observed with fraction rTp17. The immunoreactivity results showed that fusion recombinant antigens based-immuno-slot blot techniques are suitable for use in diagnostic assays for syphilis.
Resumo:
An investigation into support for restrictions on people testing seropositive for HIV is reported on. Data were collected during telephone interviews with two-hundred adults aged eighteen to sixty-five in the Chicago metropolitan area. Using the analytic technique of LISREL, six models which attempt to explain support for restrictions were tested. It was found that the model best supported by the data indicates that two groups contribute to support for restrictions on HIV carriers - one due to intolerance of homosexuality and one to mistrust of public health officials regarding their control and management of the AIDS epidemic. The relevance of these findings for public health policy makers is discussed.
Resumo:
INTRODUCCIÓN: Se ha demostrado que la sífilis, debido a la ulceración genital que produce, es un cofactor asociado para adquirir otras enfermedades de transmisión sexual (ETS), principalmente de origen viral como herpes tipo-2, hepatitis B, y el VIH. Aunque las mujeres trabajadoras del sexo comercial (MTSC) han adquirido mejores conocimientos para prevenir las ETS, constituyen un grupo que por su heterogenicidad en términos de condición socioeconómica, estado de salud, ambiente y sitio de trabajo, manifiestan diferentes actitudes y conocimientos que hacen latente la posibilidad de adquirir y transmitir ETS incluyendo sífilis, por lo que lo estudio hace un acercamiento hacia los factores asociados a infección por Treponema pallidum en este grupo de mujeres. MÉTODO: Basado en un marco muestral, que identifica sitios donde se practica el comercio sexual femenino en la ciudad de México, se seleccionó una muestra de 807 MTSC, a quienes previo consentimiento informado, se entrevistó para que respondieran un cuestionario estructurado. Se obtuvo una muestra sanguínea para la identificación de diversos marcadores serológicos de ETS de acuerdo al manual de procedimientos para el diagnóstico de ETS. Para el diagnóstico de Treponema pallidum se utilizó una prueba de tamizaje de RPR (Bigaux Diagnóstica), y prueba confirmatoria de FTA-ABS (Pasteur Diagnostics). RESULTADOS: Las prevalencias de sífilis en la muestra de MTSC fue de 6,4% (52/807), siendo mayor en quienes trabajaban en sitios de calle comparadas con aquellas de estéticas. La edad de las mujeres entrevistadas osciló entre 17 y 58 años con una media de 29,2 años (d.s. 7,3 años). La prevalencia de sífilis fue mayor en los grupos etáreos mayores de 30 anos. La edad de inicio de relaciones sexuales varió desde 11 hasta 30 anos con una media de 16 años (d.s. 3,1 años). Los factores predictores de infección por T. pallidum, determinados mediante regresión logística ajustada, fueron: sitio de trabajo (bar y puntos de calle), NSE (medio y bajo), edad (mayores de 30 anos), antiguedad en el trabajo sexual (> 5 años), y número de clientes en una semana (>10). CONCLUSIONES: A pesar de las limitaciones de precisión estadística, queda demostrado que existe una heterogenicidad de MTSC, diferenciado principalmente por el sitio donde se desempeñan. Debe entenderse que más que grupos de riesgo de adquirir y transmitir ETS, existen prácticas sexuales de riesgo en cualquier individuo que tiene relaciones sexuales, que aunadas a infecciones predisponentes como sífilis, facilitan la transmisibilidad de otras ETS. Por lo tanto, las campañas de prevención y fomento de uso de condón, deben orientarse no sólo a las MTSC sino también a sus clientes y parejas, con la finalidad de que todos asuman la responsabilidad del sexo seguro.
Resumo:
The treatment of relapsing chronic infections (RCI) encounters many difficulties. In the present study, the use of the immuno adjuvant P40 either alone or in association with vaccinotherapy for the treatment of RCI turned out to be very effective, whereas vaccinotherapy alone was not. It is hypothesized that cell-mediated immunity may play a major role in controlling RCI, since the clinical improvement of the patients kept up with the positivation of previously negative skin tests carried out with either the specific infecting agent or with recall-anti gens.
Resumo:
Realizamos um estudo comparativo entre o xenodiagnóstico e os testes sorológicos para a doença de Chagas. Cento e cincoenta pacientes de algumas áreas endêmicas foram estudados. Quatro deles pareceram revelar um estado particular com um xenodiagnóstico positivo e uma sorologia negativa, esta realizada com quatro diferentes técnicas clássicas (teste de immunofluorescência, ELISA: Enzyme Linked Immunosorbent Assay, teste de fixação do complemento e teste de immuno-eletroforese). O soro de um dos pacientes que apresentou depressão humoral específica mostra elevada quantidade de antígenos circulantes comprovada pela técnica da immuno-eletroforese. Os Autores sugerem o uso de um teste sorológico para detectar a presença de antígenos circulantes de T. cruzi, além da utilização de testes sorológicos clássicos. Isto permitiria o diagnóstico da doença de Chagas em pacientes com uma baixa (ou mesmo inexistente) produção de anticorpos específicos.
Resumo:
One of the main difficulties related to the detection of the Hepatitis Delta Virus (HDV) antigen and antibody has been the source of the needed HD antigen since HDV containing human and animal livers are very difficult to obtain and since yield is low. This fact prompted us to try to use the serum of patients in the acute phase of HDV infection as a source of HDAg and turn to enzyme immunoassays (EIA) instead of RIA for the sake of easiness and economy in the amount of HDAg needed. The antigen for EIA was obtained from patients during the acute phase of HDV infection and the antibody from patients who have been carriers for many years. For the detection of the antigen, a sandwich type method was employed, whereas for the antibody a competition assay was developed. In order to assess the relative specificity and sensibility of the test, the antibody assay was compared to a commercial RIA (C. RIA, Abbott) and to a non-commercial RIA (NC RIA). Forty-two sera were tested by the two methods and only in two cases discrepant results were obtained. Its is concluded that: 1) sera from patients in the acute and chronic phases of HDV infection can be used as source of both antigen and antibody, for immunoassays; 2) EIA and RIA have comparable relative specificity and sensibility and 3) EIA is easier to perform, cheaper, non-hazardous, has a longer shelf-life and saves scarce HDAg.
Resumo:
Diagnostic performance indexes of sensitivity, specificity, positive predictive value and efficiency were determined for dot-ELISA and IgG-ELISA tests in 340 leishmaniasis sera. Sensitivity of the dot-ELISA was significantly lower than IgG-ELISA's; the two tests had indexes of specificity and positive predictive value of the same magnitude. Seventy-eight sera gave a negative dot-ELISA test result and a positive IgG-ELISA test result. When sera were classified according to different criteria as how to interpret this diversity, the kappa statistic did not corroborate the classification indicating that the two tests display a substantial strength of agreement. The results presented indicate that performance indexes accrued in a survey where variables arc well known may be extrapolated to other population studies if the disease presents itself as highly prevalent (due to a selection bias or not) and may be expected to discriminate a disease status among test positives.
Resumo:
The objective of the present study was to develop an efficient and reproducible protocol of immunization of guinea pigs with P. brasiliensis antigens as an animal model for future studies of protective immunity mechanisms. We tested three different antigens (particulate, soluble and combined) and six protocols in the presence and absence of Freund's complete adjuvant and with different numbers of immunizing doses and variable lenght of time between the last immunizing dose and challenge. The efficacy of the immunizing protocol was evaluated by measuring the humoral and cellular anti-P. brasiliensis immune response of the animals, using immuno-diffusion, skin test and macrophage migration inhibition test. It was observed that: 1. Three immunizing doses of the antigens induced a more marked response than two doses; 2. The highest immune response was obtained with the use of Freund's complete adjuvant; 3. Animals challenged a long time (week 6) after the last immunizing dose showed good anti-P. brasiliensis immune response; 4. The particulate antigen induced the lowest immune response. The soluble and the combined antigens were equally efficient in raising good humoral and cellular anti-P. brasiliensis immune response