6 resultados para Illinois. Office of Banks and Real Estate.

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the use of conventional polymerase chain reaction (cPCR) and real-time quantitative PCR (qPCR) in the diagnosis of human strongyloidiasis from stool samples in tropical areas. Stool samples were collected from individuals and were determined to be positive for Strongyloides stercoralis (group I), negative for S. stercoralis (group II) and positive for other enteroparasite species (group III). DNA specific to S. stercoralis was found in 76.7% of group I samples by cPCR and in 90% of group I samples by qPCR. The results show that molecular methods can be used as alternative tools for detecting S. stercoralis in human stool samples in tropical areas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Myocardial contrast echocardiography has been used for assessing myocardial perfusion. Some concerns regarding its safety still remain, mainly regarding the induction of microvascular alterations. We sought to determine the bioeffects of microbubbles and real-time myocardial contrast echocardiography (RTMCE) in a closed-chest canine model. Eighteen mongrel dogs were randomly assigned to two groups. Nine were submitted to continuous intravenous infusion of perfluorocarbon-exposed sonicated dextrose albumin (PESDA) plus continuous imaging using power pulse inversion RTMCE for 180 min, associated with manually deflagrated high-mechanical index impulses. The control group consisted of 3 dogs submitted to continuous imaging using RTMCE without PESDA, 3 dogs received PESDA alone, and 3 dogs were sham-operated. Hemodynamics and cardiac rhythm were monitored continuously. Histological analysis was performed on cardiac and pulmonary tissues. No hemodynamic changes or cardiac arrhythmias were observed in any group. Normal left ventricular ejection fraction and myocardial perfusion were maintained throughout the protocol. Frequency of mild and focal microhemorrhage areas in myocardial and pulmonary tissue was similar in PESDA plus RTMCE and control groups. The percentages of positive microscopical fields in the myocardium were 0.4 and 0.7% (P = NS) in the PESDA plus RTMCE and control groups, respectively, and in the lungs they were 2.1 and 1.1%, respectively (P = NS). In this canine model, myocardial perfusion imaging obtained with PESDA and RTMCE was safe, with no alteration in cardiac rhythm or left ventricular function. Mild and focal myocardial and pulmonary microhemorrhages were observed in both groups, and may be attributed to surgical tissue manipulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study reports the first genetic characterisation of Cryptosporidium isolates in Brazil using real-time polymerase chain reaction (RT-PCR). A total of 1,197 faecal specimens from children and 10 specimens from human immunodeficiency virus-infected patients were collected between 1999-2010 and screened using microscopy. Forty-eight Cryptosporidium oocyst-positive isolates were identified and analysed using a generic TaqMan assay targeting the 18S rRNA to detect Cryptosporidium species and two other TaqMan assays to identify Cryptosporidium hominis and Cryptosporidium parvum. The 18S rRNA assay detected Cryptosporidium species in all 48 of the stool specimens. The C. parvum TaqMan assay correctly identified five/48 stool samples, while 37/48 stool specimens were correctly amplified in the C. hominis TaqMan assay. The results obtained in this study support previous findings showing that C. hominis infections are more prevalent than C. parvum infections in Brazil and they demonstrate that the TaqMan RT-PCR procedure is a simple, fast and valuable tool for the detection and differentiation of Cryptosporidium species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dynamics of porcine circovirus type 2 (PCV2) shedding in semen of naturally infected boars was studied. Semen was collected serially each 15 or 20 days during 62 days from 5 boars from a herd and from 11 boars from an artificial insemination center. All boars were positive for PCV2 DNA by nested polymerase chain reaction of raw semen in at least two sampling dates, and most of them had detectable shedding in all sampling dates. Real-time quantitative PCR was performed in 23 samples. All samples showed low amounts of PCV2 DNA, ranging from 98 to 652 PCV2 copies/mL. No differences between the frequencies of PCV2 DNA shed in semen were found considering herds and age of boars. PCV2 shedding in the semen can occur continuously or intermittently up to 60 days in naturally infected boars at 12 to 42 months old in absence of PCV2 clinical signs. These results demonstrate sporadic and long-term shedding patterns of low amounts of PCV2 DNA in semen from naturally infected boars.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Differentiation between stunned and infarcted myocardium in the setting of acute ischemia is challenging. Real time myocardial contrast echocardiography allows the simultaneous assessment of myocardial perfusion and function. In the present study we evaluated infarcted and stunned myocardium in an experimental model using real time myocardial contrast echocardiography. Sixteen dogs underwent 180 min of coronary occlusion followed by reperfusion (infarct model) and seven other dogs were submitted to 20 min of coronary occlusion followed by reperfusion (stunned model). Wall motion abnormality and perfusional myocardial defect areas were measured by planimetry. Risk and infarct areas were determined by tissue staining. In the infarct model, the wall motion abnormality area during coronary occlusion (5.52 ± 1.14 cm²) was larger than the perfusional myocardial defect area (3.71 ± 1.45 cm²; P < 0.001). Reperfusion resulted in maintenance of wall motion abnormality (5.45 ± 1.41 cm²; P = 0.43 versus occlusion) and reduction of perfusional myocardial defect (1.51 ± 1.29 cm²; P = 0.004 versus occlusion). Infarct size determined by contrast echocardiography correlated with tissue staining (r = 0.71; P = 0.002). In the stunned model, the wall motion abnormality area was 5.49 ± 0.68 cm² during occlusion and remained 5.1 ± 0.63 cm² after reperfusion (P = 0.07). Perfusional defect area was 2.43 ± 0.79 cm² during occlusion and was reduced to 0.2 ± 0.53 cm² after reperfusion (P = 0.04). 2,3,5-Triphenyl tetrazolium chloride staining confirmed the absence of necrotic myocardium in all dogs in the stunned model. Real time myocardial contrast echocardiography is a noninvasive technique capable of distinguishing between stunned and infarcted myocardium after acute ischemia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increasing presence of products derived from genetically modified (GM) plants in human and animal diets has led to the development of detection methods to distinguish biotechnology-derived foods from conventional ones. The conventional and real-time PCR have been used, respectively, to detect and quantify GM residues in highly processed foods. DNA extraction is a critical step during the analysis process. Some factors such as DNA degradation, matrix effects, and the presence of PCR inhibitors imply that a detection or quantification limit, established for a given method, is restricted to a matrix used during validation and cannot be projected to any other matrix outside the scope of the method. In Brazil, sausage samples were the main class of processed products in which Roundup Ready® (RR) soybean residues were detected. Thus, the validation of methodologies for the detection and quantification of those residues is absolutely necessary. Sausage samples were submitted to two different methods of DNA extraction: modified Wizard and the CTAB method. The yield and quality were compared for both methods. DNA samples were analyzed by conventional and real-time PCR for the detection and quantification of Roundup Ready® soybean in the samples. At least 200 ng of total sausage DNA was necessary for a reliable quantification. Reactions containing DNA amounts below this value led to large variations on the expected GM percentage value. In conventional PCR, the detection limit varied from 1.0 to 500 ng, depending on the GM soybean content in the sample. The precision, performance, and linearity were relatively high indicating that the method used for analysis was satisfactory.