3 resultados para Heater, Chuck

em Scielo Saúde Pública - SP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work a micro-heater device to be used as an integral part of the flow analysis manifold is described. The usefulness of the device was demonstrated using it in the development of a multicommutated flow analysis procedure for the spectrophotometric determination of manganese in plant digest. The method was based on the manganese oxidation by periodate in phosphoric acid medium to form the permanganate anion. The reaction development is dependent on the temperature and it was observed that at 25 °C a time interval of ca. 15 min was necessary for the reaction to attain equilibrium. Setting the temperature to 70 ºC, this time interval could be decreased to ca. 30 s. This condition was easily attained employing the proposed micro-heater device coupled to the manifold. The procedure was applied to manganese determination in soybean digests and results compared with those obtained by inductively coupled argon plasma optical emission spectrometry (ICP-OES). No significant difference at 90% confidence level was observed. A linear response for sample concentrations ranging from 5.0 to 30.00 mg L-1 Mn2+; a relative standard deviation of 1.3% (n = 6) for a typical sample containing 6.3 mg L-1 Mn2+; a sampling rate of 22 determinations per hour; a low reagent consumption, of 12.0 mg NaIO4 per determination; and a detection limit of 1.2 mg L-1 were achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple, portable and low-cost system for odor detection was developed using a single MOS commercial sensor and a microcontroller. The temperature modulation technique was implemented applying a DC signal pulse to the sensor heater by a bipolar transistor. Two odorant profiles, ethanol and acetic acid vapors, were obtained and distinguished based on their amplitude versus time responses. Response for acetic acid was not reported by the sensor manufacturer. An ethanol vapor calibration curve was also obtained. Experimental data showed a potential behavior according to the theoretical equation of the MOS sensors. Values of logK=0.457 and α=-0.213 for a 95% confidence level were obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Data were prospectively obtained from exclusively breast-fed healthy term neonates at birth and from healthy mothers with no obstetric complication to determine risk factors for excess weight loss and hypernatremia in exclusively breast-fed infants. Thirty-four neonates with a weight loss > or = 10% were diagnosed between April 2001 and January 2005. Six of 18 infants who were eligible for the study had hypernatremia. Breast conditions associated with breast-feeding difficulties (P < 0.05), primiparity (P < 0.005), less than four stools (P < 0.001), pink diaper (P < 0.001), delay at initiation of first breast giving (P < 0.01), birth by cesarean section (P < 0.05), extra heater usage (P < 0.005), extra heater usage among mothers who had appropriate conditions associated with breast-feeding (P < 0.001), mean weight loss in neonates with pink diaper (P < 0.05), mean uric acid concentration in neonates with pink diaper (P < 0.0001), fever in hypernatremic neonates (P < 0.02), and the correlation of weight loss with both serum sodium and uric acid concentrations (P < 0.02) were determined. Excessive weight loss occurs in exclusively breast-fed infants and can be complicated by hypernatremia and other morbidities. Prompt initiation of breast-feeding after delivery and prompt intervention if problems occur with breast-feeding, in particular poor breast attachment, breast engorgement, delayed breast milk "coming in", and nipple problems will help promote successful breast-feeding. Careful follow-up of breast-feeding dyads after discharge from hospital, especially regarding infant weight, is important to help detect inadequate breast-feeding. Environmental factors such as heaters may exacerbate infant dehydration.