3 resultados para Hardware-based security

em Scielo Saúde Pública - SP


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The need for automated analyzers for industrial and environmental samples has triggered the research for new and cost-effective strategies of automation and control of analytical systems. The widespread availability of open-source hardware together with novel analytical methods based on pulsed flows have opened the possibility of implementing standalone automated analytical systems at low cost. Among the areas that can benefit from this approach are the analysis of industrial products and effluents and environmental analysis. In this work, a multi-pumping flow system is proposed for the determination of phosphorus in effluents and polluted water samples. The system employs photometric detection based on the formation of molybdovanadophosphoric acid, and the fluidic circuit is built using three solenoid micropumps. The detection is implemented with a low cost LED-photodiode photometric detection system and the whole system is controlled by an open-source Arduino Uno microcontroller board. The optimization of the timing to ensure the color development and the pumping cycle is discussed for the proposed implementation. Experimental results to evaluate the system behavior are presented verifying a linear relationship between the relative absorbance and the phosphorus concentrations for levels as high as 50 mg L-1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One hundred and twenty subjects with Chagas' cardiopathy and 120 non-infected subjects were randomly selected from first time claimants of sickness benefits in the National Institute of Social Security (INPS) in Goiás. Cases of Chagas' cardiopathy were defined based on serological test, history of residence in an endemic area and, clinical and/or electrocardiogram (ECG) alterations suggestive of Chagas' cardiomyopathy. Controls were defined as subjects with at least two negative serological tests. Case and controls were compared in the analysis for age, sex, place of birth, migration history, socio-economic level, occupation, physical exertion at work, age at affiliation and years of contribution to the social security scheme, clinical course of their disease and ECG abnormalities. Chagas' disease patients were younger than other subjects and predominantly of rural origin. Non-infected subjects presented a better socio-economic level, were performing more skilled activities and had less changes of job than cases. No important difference was observed in relation to age at affiliation to INPS. About 60% of cases have claimed for benefits within the first four years of contribution while among controls this proportion was 38.5%. Cases were involved, proportionally more than controls, in "heavy" activities. A risk of 2.3 (95%CL 1.5 - 4.6) and 1.8 (95%CL 1.2- 3.5) was obtained comparing respectively "heavy" and "moderate" physical activity against "light". A relative risk of 8.5 (95%CL 4.9 - 14.8) associated with the presence of cardiopathy was estimated comparing the initial sample of seropositive subjects and controls. A high relative risk was observed in relation to right bundle branch block (RR = 37.1 95%CL = 8.8 - 155.6) and left anterior hemiblock (RR = 4.4, 95%CL = 2.1 - 9.1).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.