27 resultados para Halogen lamp

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eighteen circular blocks of resins cured either by a LED or a halogen lamp (20, 40 and 60 s), had their top (T) and bottom (B) surfaces studied using a FT-Raman spectrometer. Systematic changes in the intensity of the methacrylate C=C stretching mode at 1638 cm-1 as a function of exposure duration were observed. The calculated degree of conversion (DC) ranged from 45.0% (B) to 52.0% (T) and from 49.0% (B) to 55.0% (T) for the LED and halogen lamp, respectively. LED and halogen light produced similar DC values with 40 and 60 s of irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The loop-mediated isothermal amplification method (LAMP) is a recently developed molecular technique that amplifies nucleic acid under isothermal conditions. For malaria diagnosis, 150 blood samples from consecutive febrile malaria patients, and healthy subjects were screened in Thailand. Each sample was diagnosed by LAMP, microscopy and nested polymerase chain reaction (nPCR), using nPCR as the gold standard. Malaria LAMP was performed using Plasmodiumgenus and Plasmodium falciparum specific assays in parallel. For the genus Plasmodium, microscopy showed a sensitivity and specificity of 100%, while LAMP presented 99% of sensitivity and 93% of specificity. For P. falciparum, microscopy had a sensitivity of 95%, and LAMP of 90%, regarding the specificity; and microscopy presented 93% and LAMP 97% of specificity. The results of the genus-specific LAMP technique were highly consistent with those of nPCR and the sensitivity of P. falciparum detection was only marginally lower.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the development and validation of a loop-mediated isothermal amplification assay (LAMP) for the rapid and specific detection of Actinobacillus pleuropneumoniae (A. pleuropneumoniae). A set of six primers were designed derived from the dsbE-like gene of A.pleuropneumoniae and validate the assay using 9 A. pleuropneumoniae reference/field strains, 132 clinical isolates and 9 other pathogens. The results indicated that positive reactions were confirmed for all A. pleuropneumoniae strains and specimens by LAMP at 63ºC for 60 min and no cross-reactivity were observed from other non-A.pleuropneumoniae including Haemophilus parasuis, Escherichia coli, Pasteurella multocida, Bordetella bronchiseptica, Streptococcus suis, Salmonella enterica, Staphylococcus, porcine reproductive and respiratory syndrome virus (PRRSV), and Pseudorabies virus. The detection limit of the conventional PCR was 10² CFU per PCR test tube, while that of the LAMP was 5 copies per tube. Therefore, the sensitivity of LAMP was higher than that of PCR. Moreover, the LAMP assay provided a rapid yet simple test of A. pleuropneumoniae suitable for laboratory diagnosis and pen-side detection due to ease of operation and the requirement of only a regular water bath or heat block for the reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bordetella bronchiseptica causes acute and chronic respiratory infections in diverse animal species and occasionally in humans. In this study, we described the establishment of a simple, sensitive and cost-efficient loop-mediated isothermal amplification (LAMP) assay for the detection of B. bronchiseptica. A set of primers towards a 235 bp region within the flagellum gene of B. bronchiseptica was designed with online software.. The specificity of the LAMP assay was examined by using 6 porcine pathogens and 100 nasal swabs collected from healthy pigs and suspect infected pigs. The results indicated that positive reactions were confirmed for all B. bronchiseptica and no cross-reactivity was observed from other non-B. bronchiseptica. In sensitivity evaluations, the technique successfully detected a serial dilutions of extracted B. bronchiseptica DNA with a detection limit of 9 copies, which was 10 times more sensitive than that of PCR. Compared with conventional PCR, the higher sensitivity of LAMP method and no need for the complex instrumentation make this LAMP assay a promising alternative for the diagnosis of B. bronchiseptica in rural areas and developing countries where there lacks of complex laboratory services.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Herpes simplex virus type 1 (HSV-1) ophthalmic disease is the most common cause of corneal blindness in humans world-wide. Current culture techniques for HSV take several days and commercially available HSV laboratory based diagnostic techniques vary in sensitivity. Our study was conducted to evaluate the use of a quicker and simpler method to herpes ophthalmic diagnosis. Corneal smears were made by firm imprints of infected mouse eyes to glass slides, after smears were fixated with cold acetone, and an indirect immunofluorescence (IIF) method was performed using monoclonal antibodies in a murine model of ophthalmic herpes. Eye swabs from infected mice were inoculated in Vero cells for virus isolation. Cytology and histology of the eye were also performed, using hematoxylin-eosin routine. Mouse eyes were examined by slit-lamp biomicroscopy for evidence of herpetic disease at various times postinoculation. We made a comparative evaluation of sensitivity, specificity and speed of methods for laboratory detection of HSV. Our results indicate that this IIF method is quick, sensitive, specific and can be useful in the diagnosis of ophthalmic herpes as demonstrated in an animal model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The flaviviral envelope proteins, E protein and precursor membrane protein, are mainly associated with the endoplasmic reticulum (ER) through two transmembrane (TM) domains that are exposed to the luminal face of this compartment. Their retention is associated with the viral assembly process. ER-retrieval motifs were mapped at the carboxy terminus of these envelope proteins. A recombinant yellow fever (YF) 17D virus expressing the reporter green fluorescent protein (GFP) with the stem-anchor (SA) region of E protein fused to its carboxy terminus was subjected to distinct genetic mutations in the SA sequence to investigate their effect on ER retention. Initially, we introduced progressive deletions of the stem elements (H1, CS and H2). In a second set of mutants, the effect of a length increase for the first TM anchor region was evaluated either by replacing it with the longer TM of human LAMP-1 or by the insertion of the VALLLVA sequence into its carboxy terminus. We did not detect any effect on the GFP localisation in the cell, which remained associated with the ER. Further studies should be undertaken to elucidate the causes of the ER retention of recombinant proteins expressed at the intergenic E/NS1 region of the YF 17D virus polyprotein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A test-chamber (K&L-Chamber) made of cardboard and acrylic plastic, and consisting in four sections (A, B, C and D) was developed by Klowden & Lea (1978) for Aedes aegypti host-seeking behavior studies. Later, Foster & Lutes (1985) also used an identical chamber to successfully evaluate the efficacy of electronic repellers. It was described here a modified K&L-Chamber for behavioral studies of Ae. aegypti adults. The chamber was made in polystyrene, consisting of three sections (A, B and C) and using a human hand and a fluorescent lamp as stimulus to attract the mosquitoes. The suitability of the present test-chamber was validated assaying 80 replicates and releasing 10 Ae. aegypti females in each replicate. The females were released in the section A and allowed to fly to the section C. A mean of 96.0% (s.e. 0.213) Ae. aegypti females successfully reached section C. The present test-chamber is cheaper and easier to handle and as efficient as K&L-Chamber, when compared to Foster & Lutes (1978) that noticed 93.8% of Ae. aegypti reaching the trap section.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

First remarks on the nesting biology of Hypodynerus andeus (Packard) (Hymenoptera, Vespidae, Eumeninae) in the Azapa valley, northern Chile. Some aspects about the nesting biology of the potter wasp Hypodynerus andeus (Packard, 1869) are reported for the first time. Observations were carried out at the Azapa valley, coastal desert of northern Chile. A total of sixty nests were collected and examined, each composed by 1-14 cells, most of them found attached to concrete lamp posts. The only preys recorded in the cells were Geometridae (Lepidoptera) caterpillars and the presence of the parasitoid Anthrax sp. (Diptera, Bombyliidae) was also recorded. A number of arthropods belonging to different groups, mainly spiders, were found occupying empty nests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Four different pseudopotentials and three methodologies were employed in the calculation of the geometry and the frequencies of metal complexes like [M(NH3)2X2] [X=halogen, M=Zn, Cd], and [Hg(NH3)2]Cl2. The vibrational assignments were carefully checked and compared to the theoretically calculated ones. Graphical procedures were employed to estimate family errors and their average behavior. The calculated results show the SBK-X basis set with the best results for the geometries and calculated frequencies, for individual species and statistical results. Its use is recommend, mainly if the neighborhood atoms are described with similar pseudopotentials. Excellent results were also obtained with the Hay and Wadt pseudopotential.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays the catalyst systems based on neodymium are the ones most used in the high cis polybutadiene production. These systems contain a neodymium compound (catalyst), an alkylaluminium compound (cocatalyst) and a halogen compound (halogenating agent). The microstructure, molecular weight characteristics and the reaction activity are influenced by the nature and concentration of catalyst system components. Those characteristics are also affected by the polymerization conditions. This paper presents a brief review on 1,4-cis-butadiene polymerization on neodymium catalysts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thin layer chromatography is a quick, inexpensive and effective way of screening mixtures of non-volatile organic compounds and it is highly recommended for analytical studies. Inspection of plates under ultraviolet light for the detection of colourless compounds should be performed before any further chemical methods are applied. Construction of a low-cost UV-viewing cabinet with lamp employing parts easily found on the local market is described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

TiO2 immobilization on concrete was studied using mixtures with cement, varnish and resin. The UV radiation sources were a germicide UV lamp and solar light. Aqueous solutions of chloroform (CHCl3) and of phenol were prepared and recirculated over the TiO2 immobilized surfaces. The immobilized TiO2 surfaces showed better photocatalytic efficiency for phenol degradation compared to the control. For CHCl3, the presence or absence of the catalyst did not cause any significant difference to its degradation efficiency. The micrographic results showed a more homogeneous surface for TiO2 immobilized in resin and varnish.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Destruction of Padron® (dye and picloram) was evaluated using a photoreactor and a solar reactor. Photolysis was observed using only a germicide lamp (GL). Black light (BL) and H2O2 (172 mmol L-1) promoted a conversion of 49% and 6% of dye and picloram, respectively. Photocatalytic processes were more efficient using TiO2/GL (96%-dye; 60%-picloram) than TiO2/BL (44%-dye; 40%-picloram). Photolysis using sunlight was not observed during PadronÒ recirculation in the reactor constructed with four borosilicate tubes. Meanwhile, adding H2O2 resulted in 12% conversion of dissolved organic compounds. Finally, the most efficient mineralization (60%) was obtained using the Fenton reaction ( H2O2-176 mmol L-1; FeSO4x6H2O-90 mmol L-1) and sunlight.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents three operationally simple laboratory protocols for monocrystal growth of small-molecule organic compounds, which have been applied with success in the last ten years for the formation of single crystals for X-ray structural studies. In addition, five structure hints were formulated as general guidelines for selecting a small-molecule organic compound as a candidate for monocrystal growth: molecular weight >200 D, melting point >100 ºC, two or more aromatic rings in the structure, at least two sites for intermolecular hydrogen bond formation, and a halogen or other heavy atom in the structure.