201 resultados para Glass samples
em Scielo Saúde Pública - SP
Resumo:
Silver containing heavy metal oxide glasses and glass ceramics of the system WO3-SbPO4-PbO-AgCl with different AgCl contents have been prepared and their thermal, structural and optical properties characterized. Glass ceramics containing metallic silver nanoparticles have been prepared by annealing glass samples at temperatures above the glass transition and analyzed by transmission electron microscopy and energy dispersive X-ray microanalysis. The presence of the metallic clusters has been also confirmed by the observation of a surface plasmon resonance band in the visible range. Cyclic voltammetric measurements indicated the presence of metallic silver into the glasses, even before to perform the thermal treatment.
Resumo:
Schistosomiasis constitutes a major public health problem, with an estimated 200 million individuals infected worldwide and 700 million people living in risk areas. In Brazil there are areas of high, medium and low endemicity. Studies have shown that in endemic areas with a low prevalence of Schistosoma infection the sensitivity of parasitological methods is clearly reduced. Consequently diagnosis is often impeded due to the presence of false-negative results. The aim of this study is to present the PCR reamplification (Re-PCR) protocol for the detection of Schistosoma mansoni in samples with low parasite load (with less than 100 eggs per gram (epg) of feces). Three methods were used for the lysis of the envelopes of the S. mansoni eggs and two techniques of DNA extraction were carried out. Extracted DNA was quantified, and the results suggested that the extraction technique, which mixed glass beads with a guanidine isothiocyanate/phenol/chloroform (GT) solution, produced good results. PCR reamplification was conducted and detection sensitivity was found to be five eggs per 500 mg of artificially marked feces. The results achieved using these methods suggest that they are potentially viable for the detection of Schistosoma infection with low parasite load.
Resumo:
Passage of malaria infected blood through a two-layered column composed of acid-washed glass beads and CF 11 cellulose removes white cells from parasitized blood. However, because use of glass beads and CF 11 cellulose requires filtration of infected blood separately through these two resins and the addition of ADP, the procedure is time-consuming and may be inapropriate for use in the field, especially when large numbers of blood samples are to be treated. Our modification of this process yields parasitized cells free of contaminating leukocytes, and because of its operational simplicity, large numbers of blood samples can be processed. Our procedure also compares well with those using expensive commercial Sepacell resins in its ability to separate leukocytes from whole blood. As a test of usefulness in molecular biologic investigations, the parasites obtained from the blood of malaria-infected patients using the modified procedure yield genomic DNA whose single copy gene, the circumsporozite gene, efficiently amplifies by polymerase chain reaction.
Resumo:
The dispersion of the samples in soil particle-size analysis is a fundamental step, which is commonly achieved with a combination of chemical agents and mechanical agitation. The purpose of this study was to evaluate the efficiency of a low-speed reciprocal shaker for the mechanical dispersion of soil samples of different textural classes. The particle size of 61 soil samples was analyzed in four replications, using the pipette method to determine the clay fraction and sieving to determine coarse, fine and total sand fractions. The silt content was obtained by difference. To evaluate the performance, the results of the reciprocal shaker (RSh) were compared with data of the same soil samples available in reports of the Proficiency testing for Soil Analysis Laboratories of the Agronomic Institute of Campinas (Prolab/IAC). The accuracy was analyzed based on the maximum and minimum values defining the confidence intervals for the particle-size fractions of each soil sample. Graphical indicators were also used for data comparison, based on dispersion and linear adjustment. The descriptive statistics indicated predominantly low variability in more than 90 % of the results for sand, medium-textured and clay samples, and for 68 % of the results for heavy clay samples, indicating satisfactory repeatability of measurements with the RSh. Medium variability was frequently associated with silt, followed by the fine sand fraction. The sensitivity analyses indicated an accuracy of 100 % for the three main separates (total sand, silt and clay), in all 52 samples of the textural classes heavy clay, clay and medium. For the nine sand soil samples, the average accuracy was 85.2 %; highest deviations were observed for the silt fraction. In relation to the linear adjustments, the correlation coefficients of 0.93 (silt) or > 0.93 (total sand and clay), as well as the differences between the angular coefficients and the unit < 0.16, indicated a high correlation between the reference data (Prolab/IAC) and results obtained with the RSh. In conclusion, the mechanical dispersion by the reciprocal shaker of soil samples of different textural classes was satisfactory. The results allowed recommending the use of the equipment at low agitation for particle size- analysis. The advantages of this Brazilian apparatus are its low cost, the possibility to simultaneously analyze a great number of samples using ordinary, easily replaceable glass or plastic bottles.
Resumo:
This study aimed at assessing the stability of passion fruit juice in glass bottles during a 120-day storage period, regarding its volatile compounds profile and sensory properties (aroma and flavor). Samples were obtained from a Brazilian tropical juice industry (Fortaleza, Brazil) and submitted to sensory and chromatographic analyses. The characteristic aroma and flavor of passion fruit were evaluated by a trained panel with a non-structured scale of 9 cm. The headspace volatile compounds were isolated from the product by suction and trapped in Porapak Q, analyzed through high-resolution gas chromatography and identified through gas chromatography-mass spectrometry (GC-MS). Twelve odoriferous compounds were monitored: ethyl butanoate, ethyl propanoate, 3-methyl-1-butanol, 3-methyl-2-butenol, (E)-3-hexenol, (Z)-3-hexenol, 3-methylbutyl acetate, benzaldehyde, ethyl hexanoate, hexyl acetate, limonene and furfural. The slight variations observed in the volatile profile were not enough to provoke significant changes in the characteristic aroma and flavor of the passion fruit juice.
Resumo:
A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.
Resumo:
With the objective of standardizing a Dot Enzyme-Linked Immunosorbent Assay (Dot-ELISA) to detect antigens of fecal bacterial enteropathogens, 250 children, aged under 36 months and of both sexes, were studied; of which 162 had acute gastroenteritis. The efficacy of a rapid screening assay for bacterial enteropathogens (enteropathogenic Escherichia coli "EPEC", enteroinvasive Escherichia coli "EIEC", Salmonella spp. and Shigella spp.) was evaluated. The fecal samples were also submitted to a traditional method of stool culture for comparison. The concordance index between the two techniques, calculated using the Kappa (k) index for the above mentioned bacterial strains was 0.8859, 0.9055, 0.7932 and 0.7829 respectively. These values express an almost perfect degree of concordance for the first two and substantial concordance for the latter two, thus enabling this technique to be applied in the early diagnosis of diarrhea in infants. With a view to increasing the sensitivity and specificity of this immunological test, a study was made of the antigenic preparations obtained from two types of treatment: 1) deproteinization by heating; 2) precipitation and concentration of the lipopolysaccharide antigen (LPS) using an ethanol-acetone solution, which was then heated in the presence of sodium EDTA
Resumo:
An indirect ELISA for determination of post-vaccination rabies antibody was applied. Purified rabies virus was used as antigen to coat plates, and staphylococcal protein A linked with horseradish peroxidase was used for detecting IgG antibody in human sera. Sera from humans, vaccinated with cell-culture vaccine or suckling-mouse-brain vaccine, were examined. ELISA results were compared to those obtained from the virus neutralization test. The mean and standard deviation of OD were determined for 126 negative sera (pre-vaccination) and for 73 sera from vaccinated persons showing antibody titers lower than 0.5 IU/ml. Results were defined as ELISA -positive, -negative or -doubtful. Establishment of a doubtful region reduced the number of sera otherwise classified as positive (false-positive sera). In this way, the sensitivity, specificity and agreement values were respectively 87.5%, 92.4% and 88.5%. No significant differences were observed in these values when the group vaccinated with cell-culture vaccine and the group vaccinated with suckling-mouse-brain vaccine were compared. It was shown that much of the disagreement between the values obtained by neutralization test and ELISA occurred in sera obtained at the beginning of the immunization process, and was probably due to the presence of IgM in the serum samples, detected only by the former test. This ELISA method can be used as a screening test in rabies laboratories regardless of the kind of vaccine used for immunization.
Resumo:
Neurocysticercosis (NC), the presence of Taenia solium metacestodes in tissues, is the most frequent and severe parasitic infection of the central nervous system. We investigated the presence of total IgE by an automated chemiluminescence assay in 53 paired cerebrospinal fluid (CSF) and serum samples from patients with NC (P) and in 40 CSF samples from individuals with other neurological disorders as the control group (C). Total IgE concentration ranged from 1.2 to 6.6 IU/ml (mean = 1.4 IU/ml, standard deviation-sd = 1.1 IU/ml) in 28.3% of CSF samples from the P group, a value significantly higher than for the C group (£1.0 IU/ml). The serum samples from the P group showed concentrations ranging from 1.0 to 2330.0 IU/ml (mean = 224.1 IU/ml, sd = 452.1 IU/ml), which were higher than the normal value cited by the manufacturer (<100.0 IU/ml) in 32.1% of the samples. A significant difference was observed in CSF samples from the P and C groups (p = 0.005) and in serum samples from the P group compared to the normal value (p = 0.005), with sera showing more frequent abnormal results.
Resumo:
We report the observation of acid-fast Cyclospora cayetanensis oocysts in a sputum sample. The patient, a 60 year-old, HIV negative man, was successfully treated for pulmonary tuberculosis during 1997. On February 1998, he was admitted to our center due to loss of weight, cough with purulent expectoration, dysphonia and a radiological picture of pulmonary fibrosis. Bacilloscopic study of sputum (negative for acid-fast bacilli) stained with Ziehl-Neelsen technique showed large (8-10 µm) spherical, acid-fast Cyclospora cayetanensis oocysts. No other pathogens were isolated on cultures from this sample or from laryngeal biopsy. Serial parasitologic studies showed C. cayetanensis and also eggs of Trichuris trichiura, Ascaris lumbricoides and Hymenolepis nana and of Entamoeba coli cysts. The patient lives in the outskirts of Buenos Aires in a brick-made house with potable water and works as builder of sewers. He travelled in several occasions to the rural area of province of Tucumán which has poor sanitary conditions. C. cayetanensis is an emergent agent of diarrhea and as far as we know this is the first time the parasite is observed in respiratory samples.
Resumo:
The possibility of detecting acute infection and immunity using body fluids that are easier to collect than blood, mainly in children, would facilitate the investigation and follow-up of outbreaks of hepatitis A (HAV). Our study was carried out to evaluate the detection of anti-HAV IgM, IgA and total antibodies in saliva using serum samples as reference. Forty three paired serum and saliva samples were analyzed. From this total, 24 samples were obtained from children and 1 from one adult during the course of acute hepatitis A; an additional 18 samples were obtained from health professionals from Adolfo Lutz Institute. The sensitivity to detect anti-HAV IgM was 100% (95%CI: 79.1 to 100.0%), employing saliva as clinical samples. In detecting anti-HAV IgA, the sensitivity was 80.8% (95%CI: 60.0 to 92.7%) and for the total antibodies was 82.1% (95%CI: 62.4 to 93.2%). The specificity was 100% for each. The rate of agreement was high comparing the results of serum and saliva samples for detecting HAV antibodies. We conclude that saliva is an acceptable alternative specimen for diagnosing acute hepatitis A infection, and for screening individuals to receive hepatitis A vaccine or immunoglobulin.
Resumo:
Serum samples (n: 110) from blood donors and high risk individuals from Cordoba, Argentina with indeterminate HIV-1 and HTLV-I/II Wb profiles were studied for specific antibodies to HTLV-I/II and HIV-1 by indirect immunofluorescence assay (IFA) and for the presence or absence of HIV-1 and HTLV-I/II specific bands by Wb. This study was carried out in order to characterize their putative reactions with HIV-1 and HTLV-I/II proteins and to resolve the retrovirus infection status of these individuals. Results indicated that blood donors sera displaying indeterminate HIV-1 or HTLV-I/II Wb patterns were not immunoreactive to HTLV-I/II and HIV-1 on IFA. However, a high rate of indeterminate HIV-1 and HTLV-I/II Wb samples from high risk individuals had positive HTLV-I/II and HIV-1 IFA results respectively. Our study supports the growing evidence that HTLV-HIV indeterminate seroreactivity in low risk population is due to a cross reaction against nonviral antigens, and in high risk populations the indeterminate samples show serological cross-recognition between HIV-1 proteins and HTLV-I/II proteins on Wb. These results point out the necessity to investigate the HTLV-I/II reactivity in indeterminate HIV-1 samples and viceversa in order to confirm the diagnosis. Finally, this study shows the potential usefulness of IFA in elucidating the status of HIV-1 and HTLV-I/II infection of individuals with indeterminate Wb profiles, thus enabling resolution of retrovirus infection status.
Resumo:
Animal and human rabies samples isolated between 1989 and 2000 were typified by means of a monoclonal antibody panel against the viral nucleoprotein. The panel had been previously established to study the molecular epidemiology of rabies virus in the Americas. Samples were isolated in the Diagnostic Laboratory of the Pasteur Institute and in other rabies diagnostic centers in Brazil. In addition to the fixed virus samples CVS-31/96-IP, preserved in mouse brain, and PV-BHK/97, preserved in cell culture, a total of 330 rabies virus samples were isolated from dogs, cats, cattle, horses, bats, sheep, goat, swine, foxes, marmosets, coati and humans. Six antigenic variants that were compatible with the pre-established monoclonal antibodies panel were defined: numbers 2 (dog), 3 (Desmodus rotundus), 4 (Tadarida brasiliensis), 5 (vampire bat from Venezuela), 6 (Lasiurus cinereus) and Lab (reacted to all used antibodies). Six unknown profiles, not compatible with the panel, were also found. Samples isolated from insectivore bats showed the greatest variability and the most commonly isolated variant was variant-3 (Desmodus rotundus). These findings may be related to the existence of multiple independent transmission cycles, involving different bat species.