81 resultados para Geometria tubular

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renal damage is an important cause of death in patients who have survived the early effects of severe crotalid envenomation. Extracellular matrix of renal tissue is altered by Crotalus toxin activities. The aim of this study was to describe how cytoskeletal proteins and basal membrane components undergo substantial alterations under the action of Crotalus vegrandis crude venom and its hemorrhagic fraction (Uracoina-1) in mice. To detect the proteins in question, the immunoperoxidase method with monoclonal and polyclonal antibodies was used. Cell types within renal lesions were characterized by phenotypic identification, by means of immunohistologic analysis of marker proteins using different primary antibodies against mesangial cells, endothelial cells, cytoskeletal proteins (intermediate filament), extracellular matrix and basal membranes. Samples for morphological study by standard procedures (biotin-streptavidin-peroxidase technique) using light microscopy were processed. Positive and negative controls for each antigen tested in the staining assay were included. After crude venom and hemorrhagic fraction inoculation of mice, the disappearance of cytoskeletal vimentin and desmin and collagen proteins in the kidney was observed. In extracellular matrix and basal membranes, collagen type IV from envenomed animals tends to disappear from 24 h to 120 h after venom injection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renal histology results are very scarce in dengue-associated rhabdomyolysis patients developing acute kidney injury (AKI). We report a case of dengue fever-induced AKI associated to rhabdomyolysis with a renal biopsy showing acute tubular necrosis (ATN) and renal deposition of myoglobin. A 28-year-old patient who presented dengue fever (DF) complicated by severe AKI and rhabdomyolysis is described. The patient required hemodialysis for three weeks. A renal biopsy revealed ATN with positive staining for myoglobin in the renal tubuli. The patient was discharged with recovered renal function. In conclusion, this case report described a biopsy proven ATN associated to DF-induced rhabdomyolysis, in which renal deposition of myoglobin was demonstrated. We suggest that serum creatine phosphokinase should be monitored in DF patients to allow for an early diagnosis of rhabdomyolysis and the institution of renal protective measures.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Analisar os resultados iniciais da utilização do enxerto tubular orgânico, utilizados para anastomoses sistêmico-pulmonares. MÉTODOS: De março/2002 a abril/2003, 10 pacientes foram submetidos à realização de shunt sistêmico pulmonar tipo Blalock-Taussig modificado utilizando um novo tipo de enxerto biológico originado da artéria mesentérica bovina tratada com poliglicol denominado L-D-Hydro. A idade variou de 3 dias a 7 anos e 60% dos pacientes eram do sexo masculino. O diagnóstico das cardiopatias foi determinado pela ecocardiografia, todos apresentando sinais clínicos de hipóxia severa (cianose). As cardiopatias foram: tetralogia de Fallot (40%), atresia tricúspide (50%), defeito do septo atrioventricular (10%). RESULTADOS: Em 10 pacientes, ocorreu um óbito por sepse e em nove houve melhora imediata na saturação de O2 ao oxímetro de pulso e da pressão parcial de oxigênio à gasometria arterial. Nenhum paciente apresentou obstrução do shunt no pós-operatório imediato ou qualquer outra complicação. Todos os pacientes mostraram shunt pérvio ao exame ecocardiográfico no pós-operatório imediato e tardio, realizado no 3º mês de pós-operatório. Nenhum paciente apresentou sangramento no intra e pós-operatório. CONCLUSÃO: O enxerto tubular L-D-HYDRO demonstrou ser promissor para a realização de shunt sistêmico pulmonar, como alternativa para produtos inorgânicos existentes no mercado, entretanto, temos de ter maior número de implantes e acompanhamento tardio para uma avaliação definitiva.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: A regurgitação mitral é a doença valvar cardíaca mais comum em todo o mundo. A ressonância magnética pode ser uma ferramenta útil para analisar os parâmetros da valva mitral. OBJETIVO: diferenciar padrões geométricos da valva mitral em pacientes com diferentes gravidades por regurgitação mitral (RM) com base na ressonância magnética cardiovascular. MÉTODOS: Sessenta e três pacientes foram submetidos à ressonância magnética cardiovascular. Os parâmetros da valva mitral analisados foram: área (mm2) e ângulo (graus) de tenting, altura do ventrículo (mm), altura do tenting (mm), folheto anterior, comprimento posterior do folheto (leaflet) e diâmetro do anulo (mm). Os pacientes foram divididos em dois grupos, um incluindo pacientes que necessitaram de cirurgia da valva mitral e o outro os que não. RESULTADOS: Trinta e seis pacientes apresentaram de RM discreta a leve (1-2+) e 27 RM de moderada a grave (3-4+). Dez (15,9%) dos 63 pacientes foram submetidos à cirurgia. Pacientes com RM mais grave tiveram maior diâmetro sistólico final do ventrículo esquerdo (38,6 ± 10,2 vs. 45,4 ± 16,8, p < 0,05) e diâmetro diastólico final esquerdo (52,9 ± 6,8 vs. 60,1 ± 12,3, p = 0,005). Na análise multivariada, a área de tenting foi a determinante mais forte de gravidade de RM (r = 0,62, p = 0,035). Comprimento do anulo (36,1 ± 4,7 vs. 41 ± 6,7, p< 0,001), área de tenting (190,7 ± 149,7 vs. 130 ± 71,3, p= 0,048) e comprimento do folheto posterior (15,1 ± 4,1 vs. 12,2 ± 3,5, p= 0,023) foram maiores em pacientes que precisaram de cirurgia da valva mitral. CONCLUSÕES: Área de tenting, anulo e comprimento do folheto posterior são possíveis determinantes da gravidade da RM. Estes parâmetros geométricos podem ser usados para individualizar a gravidade e, provavelmente, no futuro, orientar o tratamento do paciente com base na anatomia individual do aparelho mitral.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho teve por objetivo explorar a aplicabilidade da teoria de fractais no estudo da variabilidade espacial em agregação de solo. A geometria de fractais tem sido proposta como um modelo para a distribuição de tamanho de partículas. A distribuição do tamanho de agregados do solo, expressos em termos de massa, é apresentada. Os parâmetros do modelo, tais como: a dimensão fractal D, medida representativa da fragmentação do solo (quanto maior seu valor, maior a fragmentação), e o tamanho do maior agregado R L foram definidos como ferramentas descritivas para a agregação do solo. Os agregados foram coletados em uma profundidade de 0-10 cm de um Latossolo Vermelho distrófico típico álico textura argilosa, em Angatuba, São Paulo. Uma grade regular de 100 x 100 m foi usada e a amostragem realizada em 76 pontos nos quais se determinou a distribuição de agregados por via úmida, usando água, álcool e benzeno como pré-tratamentos. Pelo exame de semivariogramas, constatou-se a ocorrência de dependência espacial. A krigagem ordinária foi usada como interpolador e mapas de contorno mostraram-se de grande utilidade na descrição da variabilidade espacial de agregação do solo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The construction of a tubular hydrogen ion-selective potentiometric electrode without inner reference solution, based on the tridodecylamine (TDDA) ionophore, and its evaluation in a flow system are described. TDDA was dissolved in 2-nitrophenyl octyl ether, dispersed in a PVC membrane and applied directly to a conducting support which consisted of an epoxy resin and graphite mixture. The electrode was designed with a tubular geometry to effort facilities to be coupled as part of a flow injection network. The main working characteristics such as response time, linear pH range, selectivity and life time were evaluated and compared with those obtained which a conventionally shaped electrode based on the same sensor. The electrode showed a slope of 51-52 mV dec-1 within a linear pH range from 4.0 up to 12.0.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents an automated system for potentiometric determination of free and total cyanide which employs a homogeneous membrane tubular ion-selective electrode. After the electrode is assembled, it is connected to a system composed of 3 three-way solenoid valves, sample line, carrier line, acid stream, and gas diffusion chamber. A Turbo Pascal® computer program, developed specifically for this task, automatically performs all the steps involved in data acquisition and processing. The proposed analytical procedure offers operational simplicity, since detection is performed by a tubular electrode, whose assembly is fast and easy. The system has shown reproducibility (r.s.d. < 0.5%, n=6) and high speed (30 readings/hour); it is efficient for determination of free and total cyanide in waste waters of starch processing plants. The detection limit was 1.2x10-5 and 1.5x10-5 mol L-1, for determination of free and total cyanide, respectively. The linear response range was between 1.2x10-5 and 1.0x10-2 mol L-1 for free cyanide and between 1.5x10-5 and 1.0x10-2 for total cyanide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was carried out on the urea geometries using ab initio calculation and Monte Carlo computational simulation of liquids. The ab initio calculated results showed that urea has a non-planar conformation in the gas phase in which the hydrogen atoms are out of the plane formed by the heavy atoms. Free energies associated to the rotation of the amino groups of urea in water were obtained using the Monte Carlo method in which the thermodynamic perturbation theory is implemented. The magnitude of the free energy obtained from this simulation did not permit us to conclude that urea is non-planar in water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to compare the performances of the L'vov and integrated platforms in order to overcome the interferences found on lead determination in zidovudine by ET AAS. Pyrolysis and atomization temperatures found with integrated platform were 700 and 1400°C, respectively. The characteristic masses were 12.7 ± 1.2 pg with integrated platform and 11.1 ± 1.3 pg with grooved platform. The ratio between the slopes of zidovudine and aqueous curves shows a decrease in the interferences when the L'vov platform is used (bAZT/b aq = 0.97 ± 0.10) and the detection limit found was 0.03 µg.g-1. That ratio was 0.85 ± 0.07 with the integrated platform.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experiment introduces the undergraduate students to the crystal field theory. The electronic spectra of the octahedral complexes of [Ni(L)n]2+ (L = H2O, dmso, NH3 and en) obtained in the experiment are used to calculate 10Dq and B parameters. The experiment shows how the parameters can be calculated and correlated with the nature of the ligands and the field intensities produced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method to obtain molecular Cartesian coordinates as a function of vibrational normal modes is presented in this work. The method does not require the definition of special matrices, like the F and G of Wilson, neither of group theory. The Eckart's conditions together with the diagonalization of kinetic and potential energy are the only required expressions. This makes the present approach appropriate to be used as a preliminary study for more advanced concepts concerning vibrational analysis. Examples are given for diatomic and triatomic molecules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste artigo é analisar, a partir dos textos de Platão e de comentadores, a apresentação de argumentos a favor da utilização da matemática e da geometria como propedêutica à aprendizagem da filosofia, bem como investigar as reverberações da ontologia e da epistemologia platônicas nesse programa pedagógico. Pretende-se, ainda, apontar comparativamente similaridades entre crises nos fundamentos da matemática e seu impacto na concepção de racionalidade, tanto no universo grego antigo como na contemporaneidade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi determinar o efeito dos parâmetros que compõem os dentes de serra de fita na produção e qualidade da madeira serrada de eucalipto. Analisou-se o efeito de dois passos de dentes (57,15 mm e passo variado: 50,8 - 50,8 - 50,39 - 50,71 - 60,03 - 60,35 mm), de dois ângulos de ataque (26 e 27(0)) e de duas alturas (22 e 25,4 mm) em duas classes diamétricas (25 a 34 cm e 35 e 47 cm) de clones de híbridos Eucalyptus grandis x Eucalyptus urophylla com 15 anos de idade. Não houve ganho de qualidade quando se trabalhou com passo variado. As lâminas de serra que possuíam ângulo de ataque de 27(0) e passo único tanto com altura do dente de 22 mm quanto com 25,4 mm geraram desvios acima da espessura-meta. A menor variação em torno da espessura-meta foi obtida quando se utilizaram lâminas de serra de ângulo de ataque de 27(0) e altura do dente de 25,4 mm. O maior desvio ocorreu quando o desdobro foi efetuado com passo variado e ângulo de ataque de 26(0). A utilização de passo variado, de modo geral, foi o que apresentou maiores desvios na espessura das tábuas em relação à espessura desejada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os objetivos deste trabalho foram estimar e avaliar a dimensão fractal da rede de drenagem da bacia hidrográfica do Caeté, em Alfredo Wagner, SC, a partir de diferentes métodos, com o propósito de caracterizar as formas geomorfológicas irregulares. A rede de drenagem apresenta propriedades multifractais. As dimensões fractais para os segmentos individuais (df) e para a rede de drenagem inteira (Df) foram determinadas por métodos que se fundamentaram nas razões de Horton e pelo método da contagem de caixas (Box-Counting). A rede de drenagem tem característica de autoafinidade. A dimensão fractal proveniente da relação de parâmetros obtidos pelas Leis de Horton apresentou resultados dentro dos limiares da teoria da geometria fractal.