185 resultados para GLYCOSYL-ENZYME INTERMEDIATE

em Scielo Saúde Pública - SP


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We sequenced the internal transcribed spacer 2 of the ribosomal DNA (ITS2-DNAr) from the three Schistosoma mansoni intermediate hosts in Brazil: Biomphalaria glabrata, Biomphalaria tenagophila and Biomphalaria straminea. Analysis of a restriction map from those sequences allowed us to select putative restriction enzymes able to identify the snail species under study. Four restriction enzymes were used and HpaII provided simple species-specific profiles easily visualized in polyacrylamide gels. The use of ITS2 is advantageous as it provides a small fragment of 460 bp which may be easily amplified by PCR. In the current work, we showed that the amplification of ITS2-DNAr together with HpaII enzyme restriction is an auxiliary molecular tool for the morphological identification of such snails as well as for taxonomic and phylogenetic studies of neotropical planorbids.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During an epidemiological survey of acute respiratory infection in Rio de Janeiro, among 208 adenovirus isolates, we found two strains that we were not able, by a standard neutralization procedure, to distinguish between type 3 or 7. However, DNA restriction pattern for the two strains with different enzymes were analyzed and showed a typical Ad3h profile. Using a cross-neutralization test in which both Ad3p and Ad7p antisera were used in different concentration against 100 TCID50 of each adenovirus standard and both isolates, we were able to confirm that the two isolates belong to serotype 3. An hemagglutination inhibition test also corroborated the identification of both strains as adenovirus type 3. Comparing Ad3h and Ad3p genome, we observed 16 different restriction enzyme sites, three of which were located in genomic regions encoding polypeptides involved in neutralization sites

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The correct identification of Biomphalaria oligoza, B. orbignyi and B. peregrina species is difficult due to the morphological similarities among them. B. peregrina is widely distributed in South America and is considered a potential intermediate host of Schistosoma mansoni. We have reported the use of the polymerase chain reaction and restriction fragment length polymorphism analysis of the internal transcribed spacer region of the ribosomal DNA for the molecular identification of these snails. The snails were obtained from different localities of Argentina, Brazil and Uruguay. The restriction patterns obtained with MvaI enzyme presented the best profile to identify the three species. The profiles obtained with all enzymes were used to estimate genetic similarities among B. oligoza, B. peregrina and B. orbignyi. This is also the first report of B. orbignyi in Uruguay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to define an accurate assay for anti-adenovirus antibody detection, a recently developed ELISA was compared with IFA and CF. On 58 sera, the ELISA was more sensitive than both CF and IFA, which showed relative sensitivities of 63% and 94%, respectively. It was not possible to determine the exact specificity of the tests because of the lack of a gold standard. Furthermore, the ELISA was used to define the prevalence of adenovirus antibodies in 116 infants between 1 and 24 months old (mean 7.28). The data showed that maternal antibodies waned by the age of 5 to 6 months and that more than 80% of the children had been infected by adenoviruses by the age of 10 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sera from 472 Brazilian subjects, confirmed to be either positive or negative for HIV antibodies and comprising the total clinical spectrum of HIV infection, were utilized in the evaluation of six commercially available enzyme-linked immunosorbent assays (ELISA), as well as of four alternative assays, namely indirect immunofluorescence (IIF), passive hemagglutination (PHA), dot blot and Karpas AIDS cell test. The sensitivities ranged from 100% (Abbott and Roche ELISA) to 84.2% (PHA) and the specificities ranged from 99.3% (IIF) to 80.2% (PHA). The sensitivity and specificity of the PHA and the sensitivity of the Karpas cell test were significantly lower than those of the other tests. Although the IFF and dot blot had good sensitivities and specificities, the six ELISA were more attractive than those tests when other parameters such as ease of reading and duration of assay were considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Enzyme-linked immunosorbent assay ELISA was evaluated for the detection of IgA antibodies in the human leptospirosis. The assay proved to be sensitive and specific when compared with the ELISA-IgM, in the examinated serum samples. The results found suggest that IgA antibodies became positive later in leptospirosis, and will can be an evolutive indicator in the development of the disease

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydatid disease in tropical areas poses a serious diagnostic problem due to the high frequence of cross-reactivity with other endemic helminthic infections. The enzyme-linked-immunosorbent assay (ELISA) and the double diffusion arc 5 showed respectively a sensitivity of 73% and 57% and a specificity of 84-95% and 100%. However, the specificity of ELISA was greatly increased by using ovine serum and phosphorylcholine in the diluent buffer. The hydatic antigen obtained from ovine cyst fluid showed three main protein bands of 64,58 and 30 KDa using SDS PAGE and immunoblotting. Sera from patients with onchocerciasis, cysticercosis, toxocariasis and Strongyloides infection cross-reacted with the 64 and 58 KDa bands by immunoblotting. However, none of the analyzed sera recognized the 30 KDa band, that seems to be specific in this assay. The immunoblotting showed a sensitivity of 80% and a specificity of 100% when used to recognize the 30 KDa band.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new serological test, the gelatin particle agglutination test (GPAT), was used for the serodiagnosis of schistosomiasis mansoni. This technique showed the sensitivity (90.6%) and specificity (97.8%) close to those of enzyme-linked immunosorbent assay. The GPAT can be easily and rapidly performed without specialized equipment, by using lyophilized antigen-coated gelatin particles. The test also seems to be useful for mass screening of Schistosoma infection in field conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sensitivity and specificity of an enzyme-linked immunosorbent assay (ELISA) for the detection of circulating antigens from toxic components of Tityus serrulatus scorpion venom was determined in patients stung by T. serrulatus before antivenom administration. Thirty-seven patients were classified as mild cases and 19 as moderate or severe cases. The control absorbance in the venom assay was provided by serum samples from 100 individuals of same socioeconomic group and geographical area who had never been stung by scorpions or treated with horse antisera. The negative cutoff value (mean + 2 SD) corresponded to a venom concentration of 4.8 ng/ml. Three out of the 100 normal sera were positive, resulting in a specificity of 97%. The sensitivity of the ELISA when all cases of scorpion sting were included was 39.3%. When mild cases were excluded, the sensitivity increased to 94.7%. This study showed that this ELISA can be used for the detection of circulating venom toxic antigens in patients with systemic manifestations following. T. serrulatus sting but cannot be used for clinical studies in mild cases of envenoming since the test does not discriminate mild cases from control patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Dot enzyme-linked immunosorbent assay (Dot-ELISA) was standardized and evaluated for the serodiagnosis of human toxoplasmosis. Out of 538 serum samples tested by the immunofluorescence test for toxoplasmosis (IFAT-IgG) as reference test, 183 (34%) were positive at cut off 1:16 and 192 (36%) were positive for Dot-ELISA-IgG at cut-off 1:256. For Dot-ELISA, co-positivity was 0.94, co-negativity 0.94 and concordance 0.88 in relation to IFAT-IgG. These results suggest the usefulness of Dot-ELISA (cut-off titer of 1:256) for the serodiagnosis of human toxoplasmosis. The main advantage of this technique is simplicity, positive test can be visually identified (colored precipitate). It does not require a special equipment and it can be used as a qualitative test to screen large numbers of samples or as a quantitative assay to determine end-point titration of individual sera.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An immunoprecipitation technique, ELIEDA (enzyme-linked-immuno-electro-diffusion assay), was evaluated for the diagnosis of Schistosoma mansoni infection with low worm burden. One hundred of serum samples from patients excreting less than 600 eggs per gram of feces (epg), with unrelated diseases and clinically healthy subjects were studied. In patients with egg counts higher than 200 epg, the sensitivities of IgM and IgG ELIEDA were 1.000 and 0.923, respectively, not differing from other Serologic techniques, such as indirect hemaglutination (IHAT), immunofluorescence (IFT) tests and immuno-electrodiffusion assay (IEDA). However in patients with low egg counts (< 100 epg), the IgG ELIEDA provided better results (0.821) than IgM ELIEDA (0.679), showing sensitivity that did not differ from that of IgG IFT (0.929), but lower than that of IgM IFT (0.964). However, its sensivity was higher than that found with IHAT (0.607) and IEDA (0.536). The specificity of IgG ELIEDA was comparable to that of other techniques. The data indicate that IgG ELIEDA might be useful for the diagnosis of slight S. mansoni infections, and the cellulose acetate membrane strips can be stored for further retrospective studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method of rubella antigen production by treatment with sodium desoxycholate for use in enzyme immunoassay (IMT-ELISA) is presented. When this assay was compared with a commercial test (Enzygnost-Rubella, Behring), in the study of 108 sera and 118 filter paper blood samples, 96.9% (219/226) overall agreement and correlation coefficient of 0.90 between absorbances were observed. Seven samples showed discordant results, negative by the commercial kit and positive by our test. Four of those 7 samples were available, being 3 positive by HI.