17 resultados para Flutter, Uncertainty, CFD

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiac disturbances are relatively common and electrocardiographic abnormalities may be found in more than 70% of patients with leptospirosis. We report the case of a 68 year-old male with severe leptospirosis who developed atrial flutter. Effective treatment was done with amiodarone. The patient became clinical stable, with complete recovery. Rigorous clinical observation and continuous electrocardiogram (ECG) monitoring may facilitate the identification of rhythm disorders, and thus prevent a probable fatal outcome, in severe cases of leptospirosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar os tipos de bloqueio obtidos nos istmos posterior (entre o anel tricuspídeo e veia cava inferior) e septal (entre o anel tricuspídeo e óstio do seio coronário), após ablação do flutter atrial (FLA). MÉTODOS: Foram submetidos à ablação por radiofreqüência (RF) 14 pacientes com FLA tipo I (9 homens) em 16 procedimentos. A ativação atrial ao redor do anel tricuspídeo foi avaliada em ritmo sinusal utilizando-se cateter "Halo" com 10 pares de eletrodos (H1-2 a H19-20), durante estimulação do seio coronário proximal (SCP) e região póstero-lateral do átrio direito (H1-2), antes e após ablações lineares. De acordo com a frente de programação do impulso definiu-se: ausência de bloqueio (condução bidirecional), bloqueio incompleto (condução bidirecional com retardo num dos sentidos) e bloqueio completo (ausência de condução pelo istmo). O intervalo desta ativação (deltaSCP/H1-2) foi analisado. RESULTADOS: Bloqueio completo foi obtido em 7 procedimentos (44%) e incompleto em 4 (25%). O deltaSCP/H1-2 foi de 74 ± 26ms no primeiro grupo e de 30,5 ± 7,5ms no segundo (p<0,05). Em 5 casos não demonstrou-se bloqueio. Num seguimento médio de 12 meses, ocorreu recorrência do FLA nos 6 pacientes com bloqueio incompleto ou ausente e em nenhum com bloqueio completo (p<0,001). CONCLUSÃO: A verificação de bloqueio completo pelo mapeamento multipolar atrial é uma estratégia eficaz para definir o sucesso e recorrência clínica na ablação do FLA tipo I.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Estudar a importância clínica da determinação eletrofisiológica da presença de bloqueio bidirecional na condução pelo istmo localizado entre a veia cava inferior e o anel da valva tricúspide (VCI - AT), após a ablação do flutter atrial tipo I (FL) com radiofreqüência (RF). MÉTODOS: Quarenta pacientes consecutivos (idade média 51±11 anos) com FL foram submetidos a ablação do istmo VCI-AT com RF. Em 30 pacientes (GI), o sucesso foi avaliado pela interrupção e não reindução do FL com estimulação atrial programada. Nos últimos 10 pacientes foi avaliada também a condução bidirecional pelo istmo, com cateteres posicionados na sua entrada e saída e em cada lado da linha de bloqueio. O bloqueio foi considerado bidirecional quando ocorrido nos dois sentidos e unidirecional quando ocorrido em um só sentido. RESULTADOS: Vinte e seis (86%) pacientes do GI e 10 (100%) do GII tiveram sucesso imediato (p= 0,5558). Durante o seguimento, 7 (30%) de 23 pacientes do GI e 3 (30%) de 9 do GII tiveram recorrência de FL (p= NS). Os três pacientes do GII que apresentaram recorrência tinham bloqueio unidirecional, enquanto os seis casos sem recorrência tinham bloqueio bidirecional (p=0,012). CONCLUSÃO: A demonstração de bloqueio bidirecional no istmo VCI-AT, obtida imediatamente após a ablação do FL com RF, relaciona-se a menor índice de recorrência clínica, devendo ser o critério preferencial para término do procedimento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a efetividade do metoprolol na prevenção de fibrilação e flutter atrial clinicamente detectáveis após cirurgia de revascularização miocárdica. MÉTODOS: Ensaio clínico, randomizado e aberto, para tratar 200 pacientes submetidos à cirurgia de revascularização miocárdica isolada com circulação extracorpórea, randomizados para receber metoprolol, por via oral, ou para não receber a medicação no pós-operatório. Os desfechos de interesse eram a detecção de fibrilação e flutter atrial sustentados, sintomáticos ou que requeressem tratamento. Excluídos do estudo os pacientes com fração de ejeção basal do ventrículo esquerdo < 35%, fibrilação atrial prévia, história de broncoespasmo, bloqueios atrioventriculares de 2º e 3º grau, baixo débito cardíaco e insuficiência cardíaca. RESULTADOS: Arritmias ocorreram em 11 de 100 pacientes do grupo metoprolol e em 24 de 100 pacientes do grupo controle (p=0,02). O risco relativo (RR) foi 0,46 (IC de 95%= 0,24-0,88) e o número necessário para tratar (NNT) e evitar o desfecho foi de 8 pacientes. A fibrilação atrial foi a arritmia mais freqüentemente observada (30/35). Em 38 pacientes com idade > 70 anos, as arritmias ocorreram em 2 de 19 pacientes do grupo metoprolol e em 10 de 19 do grupo controle (c2 Yates: p=0,01). O risco relativo foi 0,20 (IC de 95%= 0,05-0,79) e o número necessário para tratar foi de 2 pacientes. CONCLUSÃO: O metoprolol é efetivo na prevenção de fibrilação e flutter atrial no PO de cirurgia de revascularização miocárdica, sendo esse efeito mais marcante no grupo de pacientes idosos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVOS: Avaliar se a administração de amiodarona, em doses altas e curso rápido, reduz a incidência de fibrilação ou flutter atrial, após cirurgia de revascularização miocárdica e se reduz, também, o tempo de internação hospitalar. MÉTODOS: A amostra se constituiu de 93 pacientes randomizados, em estudo duplo-cego, para receberem amiodarona (46 pacientes) ou placebo (47 pacientes). A terapia consistia na aplicação de 600mg de amiodarona, três vezes ao dia, iniciada no mínimo 30 horas e no máximo 56 horas antes da cirurgia. RESULTADOS: Fibrilação ou flutter atrial no pós-operatório ocorreu em 8 dos 46 pacientes no grupo amiodarona (17,4%) e em 19 dos 47 pacientes no grupo placebo (40,4%) (p=0,027). A dose média de amiodarona foi de 2,8g. Os pacientes do grupo amiodarona ficaram hospitalizados por 8,9±3,1 dias, enquanto a internação dos pacientes do grupo placebo foi de 11,4± 8,7 dias (p=0,07). O tempo de internação foi significativamente prolongado nos pacientes que desenvolveram fibrilação ou flutter atrial após a cirurgia, independente do grupo randomizado. CONCLUSÃO: Esta nova alternativa de administração de amiodarona em alta dose e por um curto período, antes da cirurgia de revascularização miocárdica, reduz a incidência de fibrilação ou flutter atrial no pós-operatório desta cirurgia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVOS: Trabalho prospectivo, randomizado para comparar a eficácia e a segurança do cateter irrigado em relação ao cateter com eletrodo distal de 8 mm para ablação com radiofreqüência (RF) do flutter atrial. MÉTODOS: Em 52 pacientes consecutivos referidos para tratamento do flutter atrial típico, a ablação do istmo cavotricuspídeo (Ist-CT) foi realizada com cateter de irrigação fechada (n=26) ou com cateter de eletrodo distal de 8 mm (n=26). Os pulsos de RF foram aplicados ponto a ponto por 60 segundos com potência limitada a 50 w com o cateter irrigado e por controle de temperatura (60ºC, 70 w) com cateter de 8 mm. O critério de fim do procedimento foi a obtenção de bloqueio bidirecional do Ist-CT. RESULTADOS: O bloqueio Ist-CT foi obtido em 98,1% dos pacientes. O "crossover" ocorreu em quatro pacientes do grupo com cateter irrigado. Não se encontrou diferença estatística significante em relação aos parâmetros da ablação, tais como tempo total de aplicação de RF (591,1±309,0s vs 486,2±250,8s), duração do procedimento (86,4 ± 23,6 vs 78,1±22,5min) e tempo de fluoroscopia (17,0±6,7 vs 15,4±4,6min) entre os dois grupos. Durante seguimento médio de 10,6 meses, um paciente do grupo irrigado apresentou recorrência do flutter atrial típico. CONCLUSÃO: A ablação do Ist-CT resultou ser efetiva e segura para o controle do flutter atrial com ambas as técnicas empregadas (cateter com eletrodo distal de 8 mm e cateter irrigado). A complexidade técnica do cateter irrigado proporciona menor competitividade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: A ocorrência de fibrilação atrial (FA) após a ablação com sucesso do flutter atrial istmo cavo-tricuspídeo (FLA-ICT) dependente consiste em um evento de importância clínica. Os fatores preditores dessa ocorrência ainda são controversos. OBJETIVO: Determinar a incidência de FA e os fatores preditores para a sua ocorrência nos pacientes submetidos a ablação do flutter atrial istmo cavo-tricuspídeo (FLA-ICT) dependente. MÉTODOS: Cinquenta e dois pacientes portadores de FLA-ICT foram submetidos à ablação no período de janeiro de 2003 a março de 2004, no InCor do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. RESULTADOS: Durante o seguimento médio de 26,2 (± 9,2) meses, 16 (30,8%) pacientes apresentaram FA. A análise univariada revelou duas variáveis clínicas como preditoras de ocorrência de FA após a ablação do FLA-ICT maior ou igual a três anos (RR: 3,00; P = 0,020). Na análise multivariada, esses fatores foram variáveis independentes associadas à ocorrência de FA após ablação do FLA-ICT. CONCLUSÃO: A FA é frequentemente observada durante o seguimento dos pacientes após ablação de FLA-ICT dependente. O FLA-ICT persistente e a história de arritmia maior que três anos são fatores preditores para a ocorrência de FA durante o seguimento clínico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction:Atrial fibrillation and atrial flutter account for one third of hospitalizations due to arrhythmias, determining great social and economic impacts. In Brazil, data on hospital care of these patients is scarce.Objective:To investigate the arrhythmia subtype of atrial fibrillation and flutter patients in the emergency setting and compare the clinical profile, thromboembolic risk and anticoagulants use.Methods:Cross-sectional retrospective study, with data collection from medical records of every patient treated for atrial fibrillation and flutter in the emergency department of Instituto de Cardiologia do Rio Grande do Sul during the first trimester of 2012.Results:We included 407 patients (356 had atrial fibrillation and 51 had flutter). Patients with paroxysmal atrial fibrillation were in average 5 years younger than those with persistent atrial fibrillation. Compared to paroxysmal atrial fibrillation patients, those with persistent atrial fibrillation and flutter had larger atrial diameter (48.6 ± 7.2 vs. 47.2 ± 6.2 vs. 42.3 ± 6.4; p < 0.01) and lower left ventricular ejection fraction (66.8 ± 11 vs. 53.9 ± 17 vs. 57.4 ± 16; p < 0.01). The prevalence of stroke and heart failure was higher in persistent atrial fibrillation and flutter patients. Those with paroxysmal atrial fibrillation and flutter had higher prevalence of CHADS2 score of zero when compared to those with persistent atrial fibrillation (27.8% vs. 18% vs. 4.9%; p < 0.01). The prevalence of anticoagulation in patients with CHA2DS2-Vasc ≤ 2 was 40%.Conclusions:The population in our registry was similar in its comorbidities and demographic profile to those of North American and European registries. Despite the high thromboembolic risk, the use of anticoagulants was low, revealing difficulties for incorporating guideline recommendations. Public health strategies should be adopted in order to improve these rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper considers some issue in the governance of the European Protected Designation of Origin (PDO). The PDO systems are the outcomes of both farmers and consumers expectations and connect the valorisation of the agricultural and rural resources of given territories to the quality of typical products. A critical point in the governance of the PDO systems is represented by the connection between the quality strategies and the uncertainty. The paper argues that the PDO systems can be thought of as strictly coordinated subsystems in which the ex post governance play a critical role in coping with quality uncertainty. The study suggests that the society's inducements given raise to complex organizational systems in which the allocation of decision rights to PDO collective organizations play a major role. The empirical analysis is carried out by examining ten Italian PDO systems in order to identify the decision rights allocated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The article discusses the behavioral aspects that affect the entrepreneurs' decision making under the Knightian uncertainty approach. Since the profit arising from entrepreneurial activity represents the reward of an immeasurable and subjective risk, it has been hypothesized that innovative entrepreneurs have excessive optimism and confidence, which leads them to invest in high-risk activities. A behavioral model of decision making under uncertainty is used to test the hypothesis of overconfidence. This model is based on Bayesian inference, which allows us to model the assumption that these entrepreneurs are overconfident. We conclude that, under the hypothesis of overconfidence, these entrepreneurs decide to invest, despite the fact that the expected utility model indicates the contrary. This theoretical finding could explain why there are a large number of business failures in the first years of activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of spatial uncertainty in the prediction of nutrient losses by erosion associated with landscape models is an important tool for soil conservation planning. The purpose of this study was to evaluate the spatial and local uncertainty in predicting depletion rates of soil nutrients (P, K, Ca, and Mg) by soil erosion from green and burnt sugarcane harvesting scenarios, using sequential Gaussian simulation (SGS). A regular grid with equidistant intervals of 50 m (626 points) was established in the 200-ha study area, in Tabapuã, São Paulo, Brazil. The rate of soil depletion (SD) was calculated from the relation between the nutrient concentration in the sediments and the chemical properties in the original soil for all grid points. The data were subjected to descriptive statistical and geostatistical analysis. The mean SD rate for all nutrients was higher in the slash-and-burn than the green cane harvest scenario (Student’s t-test, p<0.05). In both scenarios, nutrient loss followed the order: Ca>Mg>K>P. The SD rate was highest in areas with greater slope. Lower uncertainties were associated to the areas with higher SD and steeper slopes. Spatial uncertainties were highest for areas of transition between concave and convex landforms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT The citriculture consists in several environmental risks, as weather changes and pests, and also consists in considerable financial risk, mainly due to the period ofreturn on the initial investment. This study was motivated by the need to assess the risks of a business activity such as citriculture. Our objective was to build a stochastic simulation model to achieve the economic and financial analysis of an orange producer in the Midwest region of the state of Sao Paulo, under conditions of uncertainty. The parameters used were the Net Present Value (NPV), the Modified Internal Rate of Return(MIRR), and the Discounted Payback. To evaluate the risk conditions we built a probabilistic model of pseudorandom numbers generated with Monte Carlo method. The results showed that the activity analyzed provides a risk of 42.8% to reach a NPV negative; however, the yield assessed by MIRR was 7.7%, higher than the yield from the reapplication of the positive cash flows. The financial investment pays itself after the fourteenth year of activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditionally, in the cigarettes industry, the determination of ammonium ion in the mainstream smoke is performed by ion chromatography. This work studies this determination and compares the results of this technique with the use of external and internal standard calibration. A reference cigarette sample presented measurement uncertainty of 2.0 μg/cigarette and 1.5 μg/cigarette, with external and internal standard, respectively. It is observed that the greatest source of uncertainty is the bias correction factor and that it is even more significant when using external standard, confirming thus the importance of internal standardization for this correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to validate a method for organic Hg determination in sediment. The procedure for organic Hg was adapted from literature, where the organomercurial compounds were extracted with dichloromethane in acid medium and subsequent destruction of organic compounds by bromine chloride. Total Hg was performed according to 3051A USEPA methodology. Mercury quantification for both methodologies was then performed by CVAAS. Methodology validation was verified by analyzing certified reference materials for total Hg and methylmercury. The uncertainties for both methodologies were calculated. The quantification limit of 3.3 µg kg-1 was found for organic Hg by CVAAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fuzzy ruled-based system was developed in this study and resulted in an index indicating the level of uncertainty related to commercial transactions between cassava growers and their dealers. The fuzzy system was developed based on Transaction Cost Economics approach. The fuzzy system was developed from input variables regarding information sharing between grower and dealer on “Demand/purchase Forecasting”, “Production Forecasting” and “Production Innovation”. The output variable is the level of uncertainty regarding the transaction between seller and buyer agent, which may serve as a system for detecting inefficiencies. Evidences from 27 cassava growers registered in the Regional Development Offices of Tupa and Assis, São Paulo, Brazil, and 48 of their dealers supported the development of the system. The mathematical model indicated that 55% of the growers present a Very High level of uncertainty, 33% present Medium or High. The others present Low or Very Low level of uncertainty. From the model, simulations of external interferences can be implemented in order to improve the degree of uncertainty and, thus, lower transaction costs.