127 resultados para Flow Chamber
em Scielo Saúde Pública - SP
Resumo:
There is a great demand for simpler and less costly laboratory techniques and for more accessible procedures for orchid breeders who do not have the necessary theoretical basis to use the traditional seed and clone production methods of orchids in vitro. The aim of this study was to assess the use of sodium hypochlorite (NaClO) as a decontaminant in the process of inoculating adult orchid explants of Arundina bambusifolia and Epidendrum ibaguenses. Solutions of NaClO (1.200, 2.400, 3.600, 4.800 and 6.000 mg L-1 - equivalent to 50, 100, 150, 200 and 250 mL L-1 of commercial bleach - CB) were sprayed on the explants (1.0 mL) and the culture medium (GB5), in the presence or absence of activated charcoal (2 g L-1). The explants used were nodal segments of field-grown adult plants. The procedures for inoculating the explants were conducted outside the laminar flow chamber (LFC), except for the control treatment (autoclaved medium and explant inoculation inside the LFC). The best results for fresh weight yield, height and number of shoots were obtained using NaClO in solution at 1.200 mg L-1 (equivalent to 50 mL L-1 commercial bleach) with activated charcoal in the culture medium. Fresh weight figures were 1.10 g/jar for Arundina bambusifolia and 0.16 g/jar for Epidendrum ibaguenses. Spraying the NaClO solutions controls the contamination of the culture medium already inoculated with the explants.
Resumo:
The rate of carbon dioxide production is commonly used as a measure of microbial activity in the soil. The traditional method of CO2 determination involves trapping CO2 in an alkali solution and then determining CO2 concentration indirectly by titration of the remaining alkali in the solution. This method is still commonly employed in laboratories throughout the world due to its relative simplicity and the fact that it does not require expensive, specific equipment. However, there are several drawbacks: the method is time-consuming, requires large amounts of chemicals and the consistency of results depends on the operator's skills. With this in mind, an improved method was developed to analyze CO2 captured in alkali traps, which is cheap and relatively simple, with a substantially shorter sample handling time and reproducibility equivalent to the traditional titration method. A comparison of the concentration values determined by gas phase flow injection analysis (GPFIA) and titration showed no significant difference (p > 0.05), but GPFIA has the advantage that only a tenth of the sample volume of the titration method is required. The GPFIA system does not require the purchase of new, costly equipment but the device was constructed from items commonly found in laboratories, with suggestions for alternative configurations for other detection units. Furthermore, GPFIA for CO2 analysis can be equally applied to samples obtained from either the headspace of microcosms or from a sampling chamber that allows CO2 to be released from alkali trapping solutions. The optimised GPFIA method was applied to analyse CO2 released from degrading hydrocarbons from a site contaminated by diesel spillage.
Resumo:
A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.
Resumo:
OBJECTIVE To describe the migration flows of demand for public and private hospital care among the health regions of the state of Sao Paulo, Brazil. METHODS Study based on a database of hospitalizations in the public and private systems of the state of Sao Paulo, Southeastern Brazil, in 2006. We analyzed data from 17 health regions of the state, considering people hospitalized in their own health region and those who migrated outwards (emigration) or came from other regions (immigration). The index of migration effectiveness of patients from both systems was estimated. The coverage (hospitalization coefficient) was analyzed in relation to the number of inpatient beds per population and the indexes of migration effectiveness. RESULTS The index of migration effectiveness applied to the hospital care demand flow allowed characterizing health regions with flow balance, with high emigration of public and private patients, and with high attraction of public and private patients. CONCLUSIONS There are differences in hospital care access and opportunities among health regions in the state of Sao Paulo, Brazil.
Resumo:
The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .
Resumo:
SUMMARYAIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and symptomatic phases of cryptococcosis are key components to reduce mortality. Recently, the cryptococcal antigen lateral flow assay (CrAg LFA) was included in the armamentarium for diagnosis. Unlike the other tests, the CrAg LFA is a dipstick immunochromatographic assay, in a format similar to the home pregnancy test, and requires little or no lab infrastructure. This test meets all of the World Health Organization ASSURED criteria (Affordable, Sensitive, Specific, User friendly, Rapid/robust, Equipment-free, and Delivered). CrAg LFA in serum, plasma, whole blood, or cerebrospinal fluid is useful for the diagnosis of disease caused by Cryptococcusspecies. The CrAg LFA has better analytical sensitivity for C. gattii than CrAg-latex or EIA. Prevention of cryptococcal disease is new application of CrAg LFA via screening of blood for subclinical infection in asymptomatic HIV-infected persons with CD4 counts < 100 cells/mL who are not receiving effective antiretroviral therapy. CrAg screening of leftover plasma specimens after CD4 testing can identify persons with asymptomatic infection who urgently require pre-emptive fluconazole, who will otherwise progress to symptomatic infection and/or die.
Resumo:
We report a rapid method for the flow cytometric quantitation of phagocytosis in heparinized complete peripherial blood (HCPB), using commercially available phycoerythrin-conjugated latex particles of 1µm diameter. The method is faster and shows greater reproducibility than Bjerknes' (1984) standard technique using propidium iodide-stained Candida albicans, conventionally applied to the leukocytic layer of peripherial blood but here modified for HCPB. We also report a modification of Bjerknes' Intracellular Killing Test to allow its application to HCPB.
Resumo:
Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.
Resumo:
O ML Flow e o ELISA PGL-I são testes sorológicos que detectam anticorpos IgM contra o glicolipídio fenólico I específico do Mycobacterium leprae. Para avaliar o comportamento destes testes em áreas endêmica e não endêmica para hanseníase foram estudados 351 voluntários no Brasil e no Chile, incluindo pacientes com hanseníase, controles sadios, portadores de outras doenças infecciosas, não infecciosas e dermatoses que fazem diagnóstico diferencial com hanseníase. O ponto de corte do ELISA foi estabelecido pelo método da Curva ROC (> 0,157). Em área endêmica, o ML Flow apresentou resultados positivos em 70% dos pacientes com hanseníase; o ELISA foi positivo em 53,3%. Em área não endêmica, o ML Flow foi negativo em todos os voluntários testados; o ELISA foi positivo em 4 voluntários. O ML Flow é um ensaio mais rápido, facilmente aplicável e, portanto, mais adequado para ser utilizado na Atenção Básica; o ELISA necessita, alem de uma infra-estrutura de laboratório adequada, pessoal treinado e especializado em sua execução.
Resumo:
Realizou-se estudo descritivo e exploratório relacionando as covariáveis aos resultados do teste sorológico ML Flow e baciloscopia. Foram estudados 60 casos novos de hanseníase diagnosticados no Centro de Referência em Dermatologia Sanitária. Para a baciloscopia, foi utilizada a coleta de esfregaço dérmico em quatro sítios, sendo o resultado expresso pelo índice bacilocópico. O ML Flow foi registrado de modo qualitativo e semi-quantitativo. Para o estudo da concordância, foi utilizado o índice de Kappa e, para sua interpretação, os critérios de Landis e Koch. Para análise estatística foram realizados a regressão logística e o teste de Kruskal-Wallis. O ML Flow mostrou forte associação com a baciloscopia, observou-se que o aumento gradativo do índice baciloscópico foi acompanhado pelo aumento semi-quantitativo dos níveis de anticorpos medidos pelo ML Flow, tendo sido positivo em 100% dos casos com baciloscopia positiva. Os resultados deste estudo evidenciaram que o ML Flow, por estar fortemente correlacionado à bacilocopia, poderá tornar-se um valioso instrumento auxiliar na classificação e alocação dos pacientes para fins de tratamento.
Resumo:
Estudo descritivo e exploratório correlacionando o ML Flow, a baciloscopia e a classificação em paucibacilar (PB) e multibacilar (MB), envolveu 1.041 casos novos com hanseníase em 13 municípios de Minas Gerais, de outubro de 2002 a março de 2004. A concordância entre o ML Flow e a classificação pelo número de lesões cutâneas e a baciloscopia foi moderada (Kappa:0,51 e 0,48, respectivamente) e, substancial (Kappa:0,77) com a classificação final. De janeiro de 2000 a março de 2004, a proporção de casos novos MB no Estado, passou de 78,1 para 65,8%. A queda no percentual de MB foi maior nos serviços participantes da pesquisa ML Flow (73,1 para 53,3%). A diferença de PB e MB nos serviços participantes e não participantes, de janeiro a março de 2004, foi estatisticamente significativa, indicando implicação direta e benéfica no tratamento e no controle da endemia em Minas Gerais.
Resumo:
O diagnóstico precoce da hanseníase, a correta classificação e o estudo dos fatores de risco relacionados à soropositividade, tornam-se importantes para o tratamento do doente e controle da endemia, especialmente, quando a responsabilidade pelo atendimento desses pacientes está sendo absorvida pelos serviços de atenção básica. Estudo descritivo e exploratório utilizando regressão logística avaliou a associação das variáveis: sexo, idade, modo de detecção, número de lesões cutâneas e de nervos acometidos, grau de incapacidade, baciloscopia, com o resultado do teste sorológico ML Flow, em 1.072 casos novos com hanseníase em 13 municípios de Minas Gerais. A soropositividade (50,7%) estava estatisticamente associada aos pacientes com 15 anos ou mais de idade (OR:2,6), mais de cinco lesões cutâneas (OR:7,5), mais de um nervo acometido (OR:2,4) e com baciloscopia positiva (OR:5,5 para IB<2 e OR:191,2 para IB>2), colaborando, assim, com a classificação e o tratamento adequados dos doentes.
Resumo:
A hanseníase ainda é doença endêmica no Brasil, com cerca de 40.000 novos casos por ano. Devido à dificuldade na realização de exames laboratoriais em campo, classifica-se a forma clínica contando-se lesões, o que pode causar subdiagnóstico de casos multibacilares e falha terapêutica. Para avaliar uma nova ferramenta para diagnóstico de hanseníase multibacilar, o teste ML Flow, foi realizado em 21/77 (27,3%) pacientes com hanseníase dimorfa (6 DV e 15 DT) não tratados, com até cinco lesões de pele, avaliados de acordo com a classificação de Ridley & Jopling (R&J). O teste ML Flow foi positivo em 14/21 (66,6%) pacientes (4 DV e 10 DT); em 7/21 (33,3%) pacientes (5 DT e 2 DV) o resultado foi negativo. A classificação da hanseníase baseada somente na contagem de lesões pode falhar em diagnosticar casos MB. O ML Flow é ferramenta útil no diagnóstico de hanseníase dimorfa com até cinco lesões cutâneas.
Resumo:
A hanseníase é um problema de saúde pública no Brasil. As ações de controle estão baseadas no diagnóstico e tratamento dos indivíduos doentes e na vigilância de seus contatos. Os testes sorológicos permitem identificar, entre os contatos, aqueles com maior risco de desenvolver hanseníase. O ML Flow foi utilizado em 2.840 contatos intradomiciliares de casos novos de hanseníase, diagnosticados entre outubro de 2002 e março de 2004, em Minas Gerais. O ML Flow foi positivo em 20,5% dos contatos de hanseníase, sendo maior nos contatos do sexo masculino (22,4%), nos maiores de 15 anos (21,7%), nos contatos de doentes multibacilares (23,9%). A chance de um contato ser soropositivo foi maior se convivia com caso multibacilar (OR=1,75), idade superior a 15 anos (OR=1,38) e sexo masculino (OR=1,25). O acompanhamento desses contatos permitirá, no futuro, avaliar o risco que a soropositividade representa no desenvolvimento de hanseníase.
Resumo:
Estudo transversal em menores de 18 anos, sendo 115 casos novos de hanseníase e 1.011 contatos intradomiciliares. Determinaram-se as proporções da soropositividade do ML Flow e fatores associados ao teste positivo. Observou-se soropositividade em 21,7% dos pacientes e 19,7% dos contatos. Nos pacientes, a regressão logística indicou associação com baciloscopia positiva e número de lesões cutâneas maior que cinco. A análise por árvore de decisão mostrou associação com baciloscopia, classificação de Madri, número de nervos acometidos e idade. Nos contatos, as duas análises indicaram as mesmas associações: classificação do caso-índice, idade e tipo de serviço de saúde. As variáveis que explicaram melhor a soropositividade, em menores de 18 anos, são aquelas associadas à maior carga bacilar. Assim, o teste ML Flow poderia ser utilizado também na infância para ajudar na correta classificação dos pacientes para tratamento e na identificação dos contatos com maior risco de desenvolver hanseníase.