3 resultados para Fault detection, fail-safety, fault tolerance, UAV
em Scielo Saúde Pública - SP
Resumo:
Aluminum (Al) toxicity is a major factor limiting barley growth in acid soils, and genotypes with adequate level of tolerance are needed for improving barley adaptation in Brazil. To study the inheritance of Al tolerance in Brazilian barleys, cultivars Antarctica 1, BR 1 and FM 404 were crossed to sensitive Kearney and PFC 8026, and intercrossed. Parental, F1, F2 and F6 generations were grown in nutrient solution containing 0.03, 0.05 and 0.07 mM of Al and classified for tolerance by the root tip hematoxylin staining assay. Tolerant by sensitive F2 progenies segregated three tolerant to one sensitive, fitting the 3:1 ratio expected for a single gene. The F6 populations segregated one tolerant to one sensitive also fitting a monogenic ratio. The F2 seedlings from crosses among tolerant genotypes scored the same as the parents. Since the population size used would allow detection of recombination as low as 7%, the complete absence of Al sensitive recombinants suggests that tolerance in these cultivars is most probably, controlled by the same gene. Thus, the potential for improving Al tolerance through recombination of these genotypes is very low and different gene sources should be evaluated.
Resumo:
The use of GFCI, ground-fault circuit interrupter, in the chemical laboratory is described, to improve the electrical safety of equipments such as rotary evaporators and constant temperature baths.
Resumo:
In order to evaluate the performance of a 1-h 75-g oral glucose tolerance test (OGTT) for the diagnosis of gestational diabetes mellitus (GDM), a cohort of 4998 women, 20 years or older, without previous diabetes being treated in prenatal care clinics in Brazil answered a questionnaire and performed a 75-g OGTT including fasting, 1-h and 2-h glucose measurements between their 24th and 28th gestational weeks. Pregnancy outcomes were transcribed from medical registries. GDM was defined according to WHO criteria (fasting: ≥126 mg/dL; 2-h value: ≥140 mg/dL) and macrosomia as a birth weight equal to or higher than 4000 g. Areas under the receiver operator characteristic curve (AUC) were compared and diagnostic properties of various cut-off points were evaluated. The AUCs for the prediction of macrosomia were 0.606 (0.572-0.637) for the 1-h and 0.589 (0.557-0.622) for the 2-h plasma glucose test. Similar predictability was demonstrable regarding combined adverse outcomes: 0.582 (0.559-0.604) for the 1-h test and 0.572 (0.549-0.595) for the 2-h test. When the 1-h glucose test was evaluated against a diagnosis of GDM defined by the 2-h glucose test, the AUC was 0.903 (0.886-0.919). The cut-off point that maximized sensitivity (83%) and specificity (83%) was 141 mg/dL, identifying 21% of the women as positive. A cut-off point of 160 mg/dL, with lower sensitivity (62%), had higher specificity (94%), labeling 8.6% as positive. Detection of GDM can be done with a 1-h 75-g OGTT: the value of 160 mg/dL has the same diagnostic performance as the conventional 2-h value (140 mg/dL). The simplification of the test may improve coverage and timing of the diagnosis of GDM.