10 resultados para Electronically interfaced
em Scielo Saúde Pública - SP
Resumo:
A piezoelectric detector based on a commercial quartz crystal of 3.57MHz is shown. A PTFE cell attached to the GC-column outlet holds the polymer-coated crystal, whose terminals were removed. Two TTL oscillators (reference and sensor) are used and the beating of their frequencies is monitored through a home-made counter card inserted in a microcomputer. The original thermal conductivity detector was also interfaced, but through a 12-bit analog-to-digital converter. In spite of the well-known fact that QCM has low sensitivity at high temperatures, results show significant peak deformation for low temperatures. In addition, the phenomenon is also dependent on the chemical composition of the absorbent film besides instantaneous partial pressure and chemical composition of the analyte.
Resumo:
This paper shows the assembly of an ozonization system to be used in laboratory scale, mainly to study effluent treatability. The system is simple, practical and provides easy acquisition of data when interfaced to a microcomputer. The performance of ozone generation and K La values are also described.
Resumo:
Medicinal chemistry is multi, trans and inter disciplinary on its essence. It has a great deal of challenging Brazilian chemists in the next decade. The pharmacy school is essentially attached and has an important role in the development on the field that is still in domain of big pharmaceutical industries. This work shows the challenges to face and directions to jointly follow for a myriad of researchers throughout the country. The unnamed science has to work out through specific objectives in order to diminish the problems associated with human being health. A brief history is presented where the main goal is to devise chemistry, as a natural science, and many other interfaced disciplines.
Resumo:
Isotopic and elemental analysis of N, C and S in liquid and solid samples has been simplified with the advent of automated systems. The simplest method of automation for this kind of analysis involves an elemental analyzer interfaced directly to the ion source of an IRMS (Isotope Ratio Mass Spectrometry). In the analyzer reduction system, an expressive amount of oxidized copper is generated as solid residue. This material is normally imported and the price is very high. A methodology was proposed for the recovery of metallic copper in order to recycle this reagent in the reduction system of a GC-IRMS, using the hydrogen gas in the vacuum line. Results show that it is possible to obtain a recycle of about 95 % of the initial metallic copper used in the reduction system.
Resumo:
This paper presents a new way for the construction of silver electrodes utilizing recordable CDs. The new electrodes were explored for the quantification of chloride (by potentiometry/FIA), cyanide (by amperometry/FIA) and for lead analysis (by square wave voltammetry). For the flowing measurements, a digital multimeter, connected to a microcomputer (via RS 232 interface) was used to collect directly the potential signal (for Cl- measurements) or to take the output signal from a potentiostat (for CN- measurements). The square wave voltammetry analysis was performed in a commercial instrument. The results shown good performance of the new electrodes and the detection limit (s/n = 3) attained for these three analytes were: 0.2, 50, and 200 µg L-1 for Pb2+, Cl-, and CN- respectively.
Resumo:
Carbon monoxide was detected and determined by a piezoelectric quartz crystal sensor coated with nickel(II)-phthalocyanine 50 % (v/v) solution in glycerine. Studies on the effect of temperature, flow rate, and some possible interferents were carried out. Calibration curves, sensor stability (lifetime) and the precision of measurements were also verified. The resulting selectivity is probably due to the coordinative binding between the electronically unsatured metal complexes and the analyte. The analytical curve is linear in the concentration range 0.10 to 1.0 % (v/v).
Resumo:
OBJECTIVE: To evaluate the combined treatment of ear lobe keloids. METHODS: We studied 46 consecutive patients with 81 ear lobe keloids. Patients underwent local infiltration of triamcinolone acetonide (TCN) at concentrations of 40mg/ml (Group 1), 20 mg/ml (Group 2) and 10mg/ml (Group 3). The volume of TCN infiltrate varied according to the size of the lesion. Treatment consisted of three monthly injections before surgery, excision of keloid in the fourth month and perioperative infiltration, followed by two more leaks TCN within two months. Patients used earrings pressure on the scar after operation for four months. The pressure exerted by earrings in the ear lobe was measured electronically. Post-treatment follow-up of patients was 24 months. RESULTS: TCN at concentrations of 20mg/ml and 40mg/ml were effective for the treatment of keloids, no difference between the groups (p = 0.58). However, patients in which TCN was infiltrated the 10mg/ml had poor involution of keloid and the study of this group was stopped. CONCLUSION: the combination of infiltration TCN month to 20 mg/mL (1.2mg to 2.0mg per mm3 TCN injury), surgical excision and pressure application device is effective for treatment of keloid ear lobe.
Resumo:
Important biological and clinical features of malignancy are reflected in its transcript pattern. Recent advances in gene expression technology and informatics have provided a powerful new means to obtain and interpret these expression patterns. A comprehensive approach to expression profiling is serial analysis of gene expression (SAGE), which provides digital information on transcript levels. SAGE works by counting transcripts and storing these digital values electronically, providing absolute gene expression levels that make historical comparisons possible. SAGE produces a comprehensive profile of gene expression and can be used to search for candidate tumor markers or antigens in a limited number of samples. The Cancer Genome Anatomy Project has created a SAGE database of human gene expression levels for many different tumors and normal reference tissues and provides online tools for viewing, comparing, and downloading expression profiles. Digital expression profiling using SAGE and informatics have been useful for identifying genes that have a role in tumor invasion and other aspects of tumor progression.
Resumo:
The objective of the present study was to assess esophageal motor function in 21 children (7.5 ± 2.9 years) with caustic strictures. Esophageal manometry was performed using a water-infusion system interfaced with a polygraph and displayed on a computer screen. The data were compared with those obtained from 9 healthy children. Radionuclide transit was determined by studying deglutition of a single bolus of 99mTc pertechnetate in 10 ml of water. Non-peristaltic low-amplitude and long-duration waves were the most common findings detected in patients with strictures longer than 20% of esophageal length (N = 11). Compared with the control group, these patients presented lower mean amplitude and longer mean duration of waves (24.4 ± 11.2 vs 97.9 ± 23.7 mmHg, P < 0.05, and 6.7 ± 2.4 vs 1.6 ± 0.1 s, P < 0.05, respectively). Six patients presented low-amplitude waves just below the constricted site. Ten children presented delayed esophageal transit. There was an association between dysphagia and abnormalities on manometry (P = 0.02) and between symptoms and scintigraphy data (P = 0.01). Dysphagia in caustic strictures is due to esophageal motility abnormalities, which are closely related to the scarred segment.
Resumo:
This study evaluated the dynamic behavior of total and compartmental chest wall volumes [(V CW) = rib cage (V RC) + abdomen (V AB)] as measured breath-by-breath by optoelectronic plethysmography during constant-load exercise in patients with stable chronic obstructive pulmonary disease. Thirty males (GOLD stages II-III) underwent a cardiopulmonary exercise test to the limit of tolerance (Tlim) at 75% of peak work rate on an electronically braked cycle ergometer. Exercise-induced dynamic hyperinflation was considered to be present when end-expiratory (EE) V CW increased in relation to resting values. There was a noticeable heterogeneity in the patterns of V CW regulation as EEV CW increased non-linearly in 17/30 "hyperinflators" and decreased in 13/30 "non-hyperinflators" (P < 0.05). EEV AB decreased slightly in 8 of the "hyperinflators", thereby reducing and slowing the rate of increase in end-inspiratory (EI) V CW (P < 0.05). In contrast, decreases in EEV CW in the "non-hyperinflators" were due to the combination of stable EEV RC with marked reductions in EEV AB. These patients showed lower EIV CW and end-exercise dyspnea scores but longer Tlim than their counterparts (P < 0.05). Dyspnea increased and Tlim decreased non-linearly with a faster rate of increase in EIV CW regardless of the presence or absence of dynamic hyperinflation (P < 0.001). However, no significant between-group differences were observed in metabolic, pulmonary gas exchange and cardiovascular responses to exercise. Chest wall volumes are continuously regulated during exercise in order to postpone (or even avoid) their migration to higher operating volumes in patients with COPD, a dynamic process that is strongly dependent on the behavior of the abdominal compartment.