27 resultados para Electronic defects

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the proposed treatments to repair lesions of degenerative joint disease (DJD), chondroprotective nutraceuticals composed by glucosamine and chondroitin sulfate are a non-invasive theraphy with properties that favors the health of the cartilage. Although used in human, it is also available for veterinary use with administration in the form of nutritional supplement independent of prescription, since they have registry only in the Inspection Service, which does not require safety and efficacy testing. The lack of such tests to prove efficacy and safety of veterinary medicines required by the Ministry of Agriculture and the lack of scientific studies proving its benefits raises doubts about the efficiency of the concentrations of such active substances. In this context, the objective of this study was to evaluate the efficacy of a veterinary chondroprotective nutraceutical based on chondroitin sulfate and glucosamine in the repair of osteochondral defects in lateral femoral condyle of 48 dogs, through clinical and radiographic analysis. The animals were divided into treatment group (TG) and control group (CG), so that only the TG received the nutraceutical every 24 hours at the rate recommended by the manufacturer. The results of the four treatment times (15, 30, 60 and 90 days) showed that the chondroprotective nutraceutical, in the rate, formulation and administration at the times used, did not improve clinical signs and radiologically did not influence in the repair process of the defects, since the treated and control groups showed similar radiographic findings at the end of the treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although postal questionnaires, personal interviewing, and telephone interviewing are the main methods of survey-based research, there is an increasing use of e-mail as a data collection medium. However, little, if any, published Western research in general and that of Turkish in particular have investigated e-mail survey technique from pure survey research perspective. Attempting to develop a framework to assess e-mail as a data collection mean, the purpose of this study is to explore e-mail-based questionnaire technique from complementary angles. To this goal, sample representativeness, data quality, response rates, and advantages and disadvantages of e-mail surveying are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The State Reform processes combined with the emergence and use of Information and Communication Technology (ICT) originated electronic government policies and initiatives in Brazil. This paper dwells on Brazilian e-government by investigating the institutional design it assumed in the state's public sphere, and how it contributed to outcomes related to e-gov possibilities. The analyses were carried out under an interpretativist perspective by making use of Institutional Theory. From the analyses of interviews with relevant actors in the public sphere, such as state secretaries and presidents of public ICT companies, conclusions point towards low institutionalization of e-gov policies. The institutional design of Brazilian e-gov limits the use of ICT to provide integrated public services, to amplify participation and transparency, and to improve public policies management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In studies assessing the effects of a given exposure variable and a specific outcome of interest, confusion may arise from the mistaken impression that the exposure variable is producing the outcome of interest, when in fact the observed effect is due to an existing confounder. However, quantitative techniques are rarely used to determine the potential influence of unmeasured confounders. Sensitivity analysis is a statistical technique that allows to quantitatively measuring the impact of an unmeasured confounding variable on the association of interest that is being assessed. The purpose of this study was to make it feasible to apply two sensitivity analysis methods available in the literature, developed by Rosenbaum and Greenland, using an electronic spreadsheet. Thus, it can be easier for researchers to include this quantitative tool in the set of procedures that have been commonly used in the stage of result validation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Evaluation of the role of transesophageal echocardiography in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. METHODS: Patients were selected for percutaneous closure of ASD by transesophageal echocardiography (TEE), which was also used to monitor the procedure, helping to select the appropriate size of the Amplatzer device, to verify its position, and to access the immediate results of the procedure. During the follow-up, TEE was used to evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiac chamber diameters. RESULTS: Twenty-two (40%) of a total of 55 studied patients were selected. Thirteen underwent Amplatzer device implantation, eight are still waiting for it, and one preferred the conventional surgical treatment. All procedures were successful, which was mainly due to proper patient selection. Six (23%) patients acutely developed RS, which spontaneously disapeared at the three-month follow-up examination in three patients. There was a significant reduction in the right ventricle diastolic diameter, from 27mm (average) to 24mm and 20mm, one and three months after the procedure, respectively (p<0.0076). CONCLUSION: With the aid of TEE, percutaneous closure of ASD can be successfully, safely, and effectively performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the frequency and prevalence of congenital heart defects in a tertiary care center for children with heart diseases. METHODS: We carried out an epidemiological assessment of the first medical visit of 4,538 children in a pediatric hospital from January 1995 to December 1997. All patients with congenital heart defects had their diagnoses confirmed at least on echocardiography. The frequency and prevalence of the anomalies were computed according to the classification of sequential analysis. Age, weight, and sex were compared between the groups of healthy individuals and those with congenital heart defects after distribution according to the age group. RESULTS: Of all the children assessed, 2,017 (44.4%) were diagnosed with congenital heart disease, 201 (4.4%) with acquired heart disease, 52 (1.2%) with arrhythmias, and 2,268 (50%) were healthy children. Congenital heart diseases predominated in neonates and infants, corresponding to 71.5% of the cases. Weight and age were significantly lower in children with congenital heart defects. Ventricular septal defect was the most frequent acyanotic anomaly, and tetralogy of Fallot was the most frequent cyanotic anomaly. CONCLUSION: Children with congenital heart defects are mainly referred during the neonatal period and infancy with impairment in gaining weight. Ventricular septal defect is the most frequent heart defect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the initial clinical experience with the Helex septal occluder for percutaneous closure of atrial septal defects. METHODS: Ten patients underwent the procedure, 7 patients with ostium secundum atrial septal defects (ASD) with hemodynamic repercussions and 3 patients with pervious foramen ovale (PFO) and a history of stroke. Mean age was 33.8 years and mean weight was 55.4 kg. Mean diameter by transesophageal echocardiography and mean stretched ASD diameter were 11.33 ± 3.3mm, and 15.2 ± 3.8mm, respectively. The Qp/Qs ratio was 1.9 ± 0.3 in patients with ASD. RESULTS: Eleven occluders were placed because a patient with 2 holes needed 2 devices. It was necessary to retrieve and replace 4 devices in 3 patients. We observed immediate residual shunt (< 2mm) in 4 patients with ASD, and in those with patent foramen ovale total occlusion of the defect occurred. No complications were noted, and all patients were discharged on the following day. After 1 month, 2 patients with ASD experienced trivial residual shunts (1mm). In 1 patient, we observed mild prolapse in the proximal disk in the right atrium, without consequences. CONCLUSION: The Helex septal occluder was safe and effective for occluding small to moderate atrial septal defects. Because the implantation technique is demanding, it requires specific training of the operator. Even so, small technical failures may occur in the beginning of the learning curve, but they do not involve patient safety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Congenital heart defects (CHD) are the most prevalent group of structural abnormalities at birth and one of the main causes of infant morbidity and mortality. Studies have shown a contribution of the copy number variation in the genesis of cardiac malformations.Objectives:Investigate gene copy number variation (CNV) in children with conotruncal heart defect.Methods:Multiplex ligation-dependent probe amplification (MLPA) was performed in 39 patients with conotruncal heart defect. Clinical and laboratory assessments were conducted in all patients. The parents of the probands who presented abnormal findings were also investigated.Results:Gene copy number variation was detected in 7/39 patients: 22q11.2 deletion, 22q11.2 duplication, 15q11.2 duplication, 20p12.2 duplication, 19p deletion, 15q and 8p23.2 duplication with 10p12.31 duplication. The clinical characteristics were consistent with those reported in the literature associated with the encountered microdeletion/microduplication. None of these changes was inherited from the parents.Conclusions:Our results demonstrate that the technique of MLPA is useful in the investigation of microdeletions and microduplications in conotruncal congenital heart defects. Early diagnosis of the copy number variation in patients with congenital heart defect assists in the prevention of morbidity and decreased mortality in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractIn children with structural congenital heart disease (CHD), the effects of chronic ventricular pacing on diastolic function are not well known. On the other hand, the beneficial effect of septal pacing over apical pacing is still controversial.The aim of this study was to evaluate the influence of different right ventricular (RV) pacing site on left ventricular (LV) diastolic function in children with cardiac defects.Twenty-nine pediatric patients with complete atrioventricular block (CAVB) and CHD undergoing permanent pacing were prospectively studied. Pacing sites were RV apex (n = 16) and RV septum (n = 13). Echocardiographic assessment was performed before pacemaker implantation and after it, during a mean follow‑up of 4.9 years.Compared to RV septum, transmitral E-wave was significantly affected in RV apical pacing (95.38 ± 9.19 vs 83 ± 18.75, p = 0.038). Likewise, parameters at the lateral annular tissue Doppler imaging (TDI) were significantly affected in children paced at the RV apex. The E´ wave correlated inversely with TDI lateral myocardial performance index (Tei index) (R2= 0.9849, p ≤ 0.001). RV apex pacing (Odds ratio, 0.648; confidence interval, 0.067-0.652; p = 0.003) and TDI lateral Tei index (Odds ratio, 31.21; confidence interval, 54.6-177.4; p = 0.025) predicted significantly decreased LV diastolic function.Of the two sites studied, RV septum prevents pacing-induced reduction of LV diastolic function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Heavy metals contained in electronic waste, if discarded improperly, can become bioavailable after vermicomposting, posing a risk to the environment. Small-scale vermicomposting experiments were carried out with printed circuit boards (PCBs) to investigate the migration of heavy metals (Cu, Pb, Zn, Ni, and Sn) to the final compost, as well as the mobility and bioavailability of these metals. High total levels of Pb, Sn and Cu in samples of manure with electronic waste (MEW) and vegetables with electronic waste (VEW) were detected. Based on the initial metal levels in the PCBs and their concentration in the resulting compost, the order of migration of these metals to the MEW and VEW samples was Sn (23.1 %)>Pb (18.4 %)>Ni (4.63 %)>Zn (0.46 %)>Cu (0.14 %) and Sn (24.3 %)>Pb (23.6 %)>Ni (11.33 %)>Zn (1.76 %)>Cu (0.60 %), respectively. Mobility and bioavailability of these metals in the compost were evaluated by three-stage sequential extraction, where F1 was the exchangeable fraction, F2 the organic fraction and F3 the residual fraction. The bioavailability factor (BF) was calculated by the ratio of the sum of fractions F1 and F2 divided by the total sum of the fractions (F1 + F2 + F3). The highest bioavailability factor (BF = 0.92) was found for Pb, the heavy metal considered the greatest environmental concern in this study, indicating the high mobility and the possibility of becoming bioavailable of this metal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Local conditions in the past often limited opportunities for scholarly exchange. But now these limits are gone and the global workplace has replaced them. It is important to react to these changes. Every academic department must now adopt new methods and rethink processes. Another is the intense national and international debate about open access to scholarly knowledge. The Open Access Initiative shows that a change is taking place in the communication process. This change is also important for service departments within research institutions. Libraries, computer centers and related units have to ask themselves how to react appropriately to the new conditions. What services must be changed or redeveloped, and in what quality and quantity should they be offered? This article focuses on changes in the scholarly publication process. It describes both technological changes and the changes needed in people's attitudes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a project led by the Instituto Brasileiro de Informações em Ciência e Tecnologia (Ibict), a government institution, to build a national digital library for electronic theses and dissertations - Bibliteca Digital de Teses e Dissertações (BDTD). The project has been a collaborative effort among Ibict, universities and other research centers in Brazil. The developers adopted a system architecture based on the Open Archives Initiative (OAI) in which universities and research centers act as data providers and Ibict as a service provider. A Brazilian metadata standard for electronic theses and dissertations was developed for the digital library. A toolkit including open source package was also developed by Ibict to be distributed to potential data providers. BDTD has been integrated with the international initiative: the Networked Digital Library of Thesis and Dissertation (NDLTD). Discussions in the paper address various issues related to project design, development and management as well as the role played by Ibict. Conclusions highlight some important lessons learned to date and challenges for the future in expanding the BDTD project.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work TiO2 films were formed over Indium Tin Oxide (ITO) employing cathodic electrophoretic deposition (Cathodic-EPD) and Dr. Blade Technique. The films were characterized by electrochemical techniques in order to compare their electronic properties; as well as, their photoelectrochemical behavior. The electrochemical performance showed by the films, allowed to relate the modification occurring during the Cathodic-EPD, with the partial reduction of TiO2 nanoparticles, generating Ti3+ defects. These trapping states are modifying the electronic properties of the film, and diminishing the transport of the photoelectrogenerated electrons toward ITO.