78 resultados para Electricity generation performance test

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the second-generation OptiMal test for malaria diagnosis under various storage conditions. It detected all the positive samples, except for two Plasmodium malariae samples. Further research evaluating diverse environmental conditions are important for ICT test applicability in Brazilian malaria areas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A preliminary survey of the spider fauna in natural and artificial forest gap formations at “Porto Urucu”, a petroleum/natural gas production facility in the Urucu river basin, Coari, Amazonas, Brazil is presented. Sampling was conducted both occasionally and using a protocol composed of a suite of techniques: beating trays (32 samples), nocturnal manual samplings (48), sweeping nets (16), Winkler extractors (24), and pitfall traps (120). A total of 4201 spiders, belonging to 43 families and 393 morphospecies, were collected during the dry season, in July, 2003. Excluding the occasional samples, the observed richness was 357 species. In a performance test of seven species richness estimators, the Incidence Based Coverage Estimator (ICE) was the best fit estimator, with 639 estimated species. To evaluate differences in species richness associated with natural and artificial gaps, samples from between the center of the gaps up to 300 meters inside the adjacent forest matrix were compared through the inspection of the confidence intervals of individual-based rarefaction curves for each treatment. The observed species richness was significantly higher in natural gaps combined with adjacent forest than in the artificial gaps combined with adjacent forest. Moreover, a community similarity analysis between the fauna collected under both treatments demonstrated that there were considerable differences in species composition. The significantly higher abundance of Lycosidae in artificial gap forest is explained by the presence of herbaceous vegetation in the gaps themselves. Ctenidae was significantly more abundant in the natural gap forest, probable due to the increase of shelter availability provided by the fallen trees in the gaps themselves. Both families are identified as potential indicators of environmental change related to the establishment or recovery of artificial gaps in the study area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increasing natural gas use in Brazil triggered a discussion of its role as a Hg source. We show that Hg emissions to the atmosphere from fossil fuel combustion for power generation in Brazil contribute with 6.2% (4.2 t yr-1) to the total anthropogenic Hg atmospheric emissions, with coal combustion and biomass burning as major sources. Natural gas contributes with 0.04 t yr-1, mostly from electricity generation (88%) and industrial uses (7.6%). Preliminary results on Hg concentrations in natural gas suggest that a large fraction of it is trapped during refining and transport, which may create Hg point sources between extraction and consumption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Brazil is considered a major player in relation to renewable energy sources. Since 2005, the MME have encouraged scientific and technological development to advance the hydrogen economy in the country. In this work we identified the patents based on hydrogen production filed by the INPI by evaluating the energy production in Brazil in conjunction with data held in the BNE and the prediction of hydrogen production made by the CGEE. It can be observed that the country needs substantial technological stimulation, but shows promise for producing renewable energy sources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Methods for reliable evaluation of spinal cord (SC) injury in rats at short periods (2 and 24 h) after lesion were tested to characterize the mechanisms implicated in primary SC damage. We measured the physiological changes occurring after several procedures for producing SC injury, with particular emphasis on sensorimotor functions. Segmental and suprasegmental reflexes were tested in 39 male Wistar rats weighing 250-300 g divided into three control groups that were subjected to a) anesthesia, b) dissection of soft prevertebral tissue, and c) laminectomy of the vertebral segments between T10 and L1. In the lesion group the SC was completely transected, hemisected or subjected to vertebral compression. All animals were evaluated 2 and 24 h after the experimental procedure by the hind limb motility index, Bohlman motor score, open-field, hot-plate, tail flick, and paw compression tests. The locomotion scale proved to be less sensitive than the sensorimotor tests. A reduction in exploratory movements was detected in the animals 24 h after the procedures. The hot-plate was the most sensitive test for detecting sensorimotor deficiencies following light, moderate or severe SC injury. The most sensitive and simplest test of reflex function was the hot-plate. The hemisection model promoted reproducible moderate SC injury which allowed us to quantify the resulting behavior and analyze the evolution of the lesion and its consequences during the first 24 h after injury. We conclude that hemisection permitted the quantitation of behavioral responses for evaluation of the development of deficits after lesions. Hind limb evaluation scores and spontaneous exploration events provided a sensitive index of immediate injury effects after SC lesion at 2 and 24 h. Taken together, locomotion scales, open-field, and hot-plate tests represent reproducible, quantitatively sensitive methods for detecting functional deficiencies within short periods of time, indicating their potential for the study of cellular mechanisms of primary injury and repair after traumatic SC injury.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper analyses the most important experiences with school accountability policy (SA) in Brazil. The analysis suggests that their impacts on the quality of education are not significant due to the fact that: (i) either it does not incorporate a system in which the school is responsible for the students’ performance; (ii) or the incentive schemes are not appropriately designed. Finally, it discusses the main barriers to the adoption of an efficient SA at the national level in Brazil.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The study was carried out to evaluate the diagnostic performance of the ICT malaria Pf/PvTM test for vivax malaria diagnosis in Belém, Amazon region, Brazil. The results of blood malaria parasites examination using an immunochromatography test were compared with thick blood film (TBF) examination. It was also evaluated the performance of this test storaged at three different temperatures (25°C, 30°C, and 37°C) for 24 hours before use. Overall sensitivity of ICT Pf/PvTM was 61.8% with a specificity of 100%, positive and negative predictive value of 100% and 71.8%, respectively and accuracy of 80.6%. The test sensitivity was independent of the parasite density. This test needs to be further reviewed in order to have better performance for P. vivax malaria diagnosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the scoring obtained by an instrument, which evaluates the ability to read and understand items in the health care setting, according to education and age. METHODS: The short version of the Test of Functional Health Literacy in Adults was administered to 312 healthy participants of different ages and years of schooling. The study was conducted between 2006 and 2007, in the city of São Paulo, Southeastern Brazil. The test includes actual materials such as pill bottles and appointment slips and measures reading comprehension, assessing the ability to read and correctly pronounce a list of words and understand both prose passages and numerical information. Pearson partial correlations and a multiple regression model were used to verify the association between its scores and education and age. RESULTS: The mean age of the sample was 47.3 years(sd=16.8) and the mean education was 9.7 years(sd=5; range: 1 - 17). A total of 32.4% of the sample showed literacy/numeracy deficits, scoring in the inadequate and marginal functional health literacy ranges. Among the elderly (65 years or older) this rate increased to 51.6%. There was a positive correlation between schooling and scores (r=0.74; p<0.01) and a negative correlation between age and the scores (r=-0.259; p<0.01). The correlation between the scores and age was not significant when the effects of education were held constant (rp=-0.031, p=0.584). A significant association (B=3.877, Beta =0.733; p<0.001) was found between schooling and scores. Age was not a significant predictor in this model (B=-0.035, Beta=-0.22; p=0.584). CONCLUSIONS: The short version of the Test of Functional Health Literacy in Adults was a suitable tool to assess health literacy in the study population. The high number of individuals classified as functional illiterates in this test highlights the importance of special assistance to help them properly understand directions for healthcare.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The performance of an antigen of L. major-like promastigotes for the serological diagnosis of mucocutaneous leishmaniasis in the IgG-immunofluorescent test was compared to that of an antigen of L. braziliensis braziliensis. Each antigen was used to test two hundred and twenty-four sera of etiologies such as mucocutaneous leishmaniasis, deep mycoses, toxoplasmosis, malaria, Chagas' disease, visceral leishmaniasis, anti-nuclear factor, schistosomaiasis, rheumatoid factor and normal controls. Agreement between responses to each antigen was high: 77.2% of leishmaniases sera agreed on a positive or a negative result to both antigens and 91.1 % of control sera. Cross reactivity was restricted to Chagas' disease sera, visceral leishmaniasis, anti-nuclear factor and paracoccidiodomycosis. The quantitative response of leishmaniasis and Chagas' disease sera to both antigens was evaluated by a linear regression; although the y-intercept and the slope were different for each antigen, neither was better than the other in the disclosure of anti-Leishmania antibodies. In the case of Chagas' disease sera the L. major-like antigen was better than L. b. braziliensis' to disclose cross-reacting antibodies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Rapid diagnostic tests (RDTs) may improve the early detection of visceral leishmaniasis (VL), but their real-world performance requires additional study. Therefore, we evaluated the performance of an rK39-based RDT (Kalazar Detect™) for the detection of VL in an endemic, large urban area. Methods Data were collected from a registry of rK39 RDT performed at 11 emergency care units in Belo Horizonte, Brazil, and from a national database of reportable communicable diseases of the Sistema de Informação de Agravos de Notificação (SINAN). Results The rapid rK39 test was performed in 476 patients, with 114 (23.9%) positive results. The analysis of rK39 RDT performance was based on 381 (80%) cases reported to the SINAN database, of which 145 (38.1%) were confirmed cases. Estimates for sensitivity and specificity were 72.4% (95% CI: 64.6-79%) and 99.6% (95%CI: 97.6-99.9%), respectively. Positive and negative predictive values were estimated at 99.1% (95%CI: 94.9-99.8%) and 85.5% (95%CI: 80.8-89.1%), respectively. In addition, close agreement between the rK39 RDT and indirect immunofluorescence was observed. Conclusions In summary, the rK39 RDT showed a high specificity but only moderate sensitivity. In endemic areas for VL, treatment may be considered in cases with clinical manifestations and a positive rK39 RDT, but those with a negative test should be subjected to further investigation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction. The genera Enterococcus, Staphylococcus and Streptococcus are recognized as important Gram-positive human pathogens. The aim of this study was to evaluate the performance of Vitek 2 in identifying Gram-positive cocci and their antimicrobial susceptibilities. Methods. One hundred four isolates were analyzed to determine the accuracy of the automated system for identifying the bacteria and their susceptibility to oxacillin and vancomycin. Results. The system correctly identified 77.9% and 97.1% of the isolates at the species and genus levels, respectively. Additionally, 81.8% of the Vitek 2 results agreed with the known antimicrobial susceptibility profiles. Conclusion. Vitek 2 correctly identified the commonly isolated strains; however, the limitations of the method may lead to ambiguous findings.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Paracoccidioidomycosis is diagnosed from the direct observation of the causative agent, but serology can facilitate and decrease the time required for diagnosis. The objective of this study was to determine the influence of serum sample inactivation on the performance of the latex agglutination test (LAT) for detecting antibodies against Paracoccidioides brasiliensis. The sensitivity of LAT from inactivated or non-inactivated samples was 73% and 83%, respectively and the LAT selectivity was 79% and 90%, respectively. The LAT evaluated here was no more specific than the double-immunodiffusion assay. We suggest the investigation of other methods for improving the LAT, such as the use of deglycosylated antigen.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

ABSTRACT The successful in the implementation of wind turbines depends on several factors, including: the wind resource at the installation site, the equipment used, project acquisition and operational costs. In this paper, the production of electricity from two small wind turbines was compared through simulation using the computer software HOMER - a national model of 6kW and an imported one of 5kW. The wind resources in three different cities were considered: Campinas (SP/BR), Cubatão (São Paulo/BR) and Roscoe (Texas/ USA). A wind power system connected to the grid and a wind isolated system - batteries were evaluated. The results showed that the energy cost ($/kWh) is strongly dependent on the windmill characteristics and local wind resource. Regarding the isolated wind system – batteries, the full supply guarantee to the simulated electrical load is only achieved with a battery bank with many units and high number of wind turbines, due to the intermittency of wind power.