31 resultados para Electrical impedance tomography, Calderon problem, factorization method

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes an electronic transducer for multiphase flow measurement. Its high sensitivity, good signal to noise ratio and accuracy are achieved through an electrical impedance sensor with a special guard technique. The transducer consists of a wide bandwidth and high slew rate differentiator where the lead inductance and stray capacitance effects are compensated. The sensor edge effect is eliminated by using a guard electrode based on the virtual ground potential of the operational amplifier. A theoretical modeling and a calibration method are also presented. The results obtained seem to confirm the validity of the proposed technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a formulation of the contact with friction between elastic bodies. This is a non linear problem due to unilateral constraints (inter-penetration of bodies) and friction. The solution of this problem can be found using optimization concepts, modelling the problem as a constrained minimization problem. The Finite Element Method is used to construct approximation spaces. The minimization problem has the total potential energy of the elastic bodies as the objective function, the non-inter-penetration conditions are represented by inequality constraints, and equality constraints are used to deal with the friction. Due to the presence of two friction conditions (stick and slip), specific equality constraints are present or not according to the current condition. Since the Coulomb friction condition depends on the normal and tangential contact stresses related to the constraints of the problem, it is devised a conditional dependent constrained minimization problem. An Augmented Lagrangian Method for constrained minimization is employed to solve this problem. This method, when applied to a contact problem, presents Lagrange Multipliers which have the physical meaning of contact forces. This fact allows to check the friction condition at each iteration. These concepts make possible to devise a computational scheme which lead to good numerical results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the relation between coronary artery disease and the calcification index on helical computed tomography. METHOD: We studied 22 patients (ages ranging from 40 to 70 years) who underwent coronary angiography because of chest pain suggestive of angina pectoris. Findings on coronary angiography were classified as follows: significant obstructive disease (stenosis > or = 50%), nonobstructive disease (stenosis <50%), and no disease. With no previous knowledge of the results of the coronary angiography and within 7 days, helical computed tomography of the chest was performed. Then, data of the coronary angiography were correlated with the calcification index obtained by helical computed tomography. RESULTS: The sensitivity of helical computed tomography to the presence of significant obstructive lesions on coronary angiography was 87.5%, specificity was 100%, and negative and positive predictive values were 75% and 100%, respectively. The mean calcification index was greater in patients with severe coronary lesions, mainly when involvement of 2 or 3 vessels occurred, than that in patients with no coronary artery disease or with nonobstructive coronary artery lesions (p<0.05). CONCLUSION: Helical computed tomography is an effective method for detecting and quantifying coronary artery calcification, and it has proved to be sensitive to and specific for the noninvasive diagnosis of coronary artery stenosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of organic devices based on conducting polymers for biofilm detection requires the combination of superior electrical response and high surface area for biofilm incorporation. Polypyrrole is a potential candidate for application in biofilm detection and control due to its characteristic superior electrical response and strong interaction with bacteria, which enables the use of the bioelectric effect in resulting devices. In this study, chemically synthesized polypyrrole was applied as a support for biofilm growth of S. aureus. Modifications in the electrical response of the polymeric template were explored to identify general mechanisms established during the deposition of the biofilm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop specific equations for the neonatal population to determine body fluid compartments. Bioelectric impedance measurements were performed by a laboratory homemade instrument. The volumes were estimated in a clinical study on 30 full-term neonates at four different times during the first month of life. During the first 24 hours of life the total body water, extracellular water and intracellular water were 2.09 ± 0.25, 1.20 ± 0.19, and 0.90 ± 0.25 liters, respectively. By the 48th hour they were 1.87 ± 0.27, 1.08 ± 0.17, and 0.79 ± 0.21 liters, respectively. On the 10th day they were 2.02 ± 0.25, 1.29 ± 0.21, and 0.72 ± 0.14 liters, respectively, and after 1 month they were 2.34 ± 0.27, 1.62 ± 0.20, and 0.72 ± 0.13 liters, respectively. The behavior of the estimated volume was correlated with neonatal body weight changes, leading to a better interpretation of such changes. In conclusion, this study indicates the feasibility of bioelectrical impedance spectroscopy as a method to help fluid administration in intensive care neonatal units, and also contribute to the development of new equations to estimate neonatal body fluid contents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we analyze the use of electrical impedance spectroscopy applied to determination of cloud point. The slope of admittance measured at 100 kHz is reduced to temperature above the critical value which characterizes the phase transition, in a strong indication that this process is activated during the clouding. Additionally to this study we explored the influence of parameters such as additives and temperature on the performance of phase separation of residues (silver nanoparticles) by cloud point extraction. The interaction with salt maximizes the separation of chemical residues in a progressively reduced temperature.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objectives of the present study were to describe and compare the body composition variables determined by bioelectrical impedance (BIA) and the deuterium dilution method (DDM), to identify possible correlations and agreement between the two methods, and to construct a linear regression model including anthropometric measures. Obese adolescents were evaluated by anthropometric measures, and body composition was assessed by BIA and DDM. Forty obese adolescents were included in the study. Comparison of the mean values for the following variables: fat body mass (FM; kg), fat-free mass (FFM; kg), and total body water (TBW; %) determined by DDM and by BIA revealed significant differences. BIA overestimated FFM and TBW and underestimated FM. When compared with data provided by DDM, the BIA data presented a significant correlation with FFM (r = 0.89; P < 0.001), FM (r = 0.93; P < 0.001) and TBW (r = 0.62; P < 0.001). The Bland-Altman plot showed no agreement for FFM, FM or TBW between data provided by BIA and DDM. The linear regression models proposed in our study with respect to FFM, FM, and TBW were well adjusted. FFM obtained by DDM = 0.842 x FFM obtained by BIA. FM obtained by DDM = 0.855 x FM obtained by BIA + 0.152 x weight (kg). TBW obtained by DDM = 0.813 x TBW obtained by BIA. The body composition results of obese adolescents determined by DDM can be predicted by using the measures provided by BIA through a regression equation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To estimate the budget impact from the incorporation of positron emission tomography (PET) in mediastinal and distant staging of non-small cell lung cancer.METHODS The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease´s prevalence and on the technologies’ accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazilian Unified Health System (SUS) database. Two strategies for using PET were analyzed: the offer to all newly-diagnosed patients, and the restricted offer to the ones who had negative results in previous computed tomography (CT) exams. Univariate and extreme scenarios sensitivity analyses were conducted to evaluate the influence from sources of uncertainties in the parameters used.RESULTS The incorporation of PET-CT in SUS would imply the need for additional resources of 158.1 BRL (98.2 USD) million for the restricted offer and 202.7 BRL (125.9 USD) million for the inclusive offer in five years, with a difference of 44.6 BRL (27.7 USD) million between the two offer strategies within that period. In absolute terms, the total budget impact from its incorporation in SUS, in five years, would be 555 BRL (345 USD) and 600 BRL (372.8 USD) million, respectively. The costs from the PET-CT procedure were the most influential parameter in the results. In the most optimistic scenario, the additional budget impact would be reduced to 86.9 BRL (54 USD) and 103.8 BRL (64.5 USD) million, considering PET-CT for negative CT and PET-CT for all, respectively.CONCLUSIONS The incorporation of PET in the clinical staging of non-small cell lung cancer seems to be financially feasible considering the high budget of the Brazilian Ministry of Health. The potential reduction in the number of unnecessary surgeries may cause the available resources to be more efficiently allocated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study describes the development and application of a new PCR assay for the specific detection of pathogenic leptospires and its comparison with a previously reported PCR protocol. New primers were designed for PCR optimization and evaluation in artificially-infected paraffin-embedded tissues. PCR was then applied to post-mortem, paraffin-embedded samples, followed by amplicon sequencing. The PCR was more efficient than the reported protocol, allowing the amplification of expected DNA fragment from the artificially infected samples and from 44% of the post-mortem samples. The sequences of PCR amplicons from different patients showed >99% homology with pathogenic leptospires DNA sequences. The applicability of a highly sensitive and specific tool to screen histological specimens for the detection of pathogenic Leptospira spp. would facilitate a better assessment of the prevalence and epidemiology of leptospirosis, which constitutes a health problem in many countries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The aims of this study were to evaluate the role of high resolution computed tomography of the torax in detecting abnormalities in chronic asthmatic patients and to determine the behavior of these lesions after at least one year. METHOD: Fourteen persistent asthmatic patients with a mean forced expiratory volume in 1-second that was 63% of predicted and a mean forced expiratory volume in 1-second /forced vital capacity of 60% had two high resolution computed tomographys separated by an interval of at least one year. RESULTS: All 14 patients had abnormalities on both scans. The most common abnormality was bronchial wall thickening, which was present in all patients on both computed tomographys. Bronchiectasis was suggested on the first computed tomography in 5 of the 14 (36%) patients, but on follow-up, the bronchial dilatation had disappeared in 2 and diminished in a third. Only one patient had any emphysematous changes; a minimal persistent area of paraseptal emphysema was present on both scans. In 3 patients, a "mosaic" appearance was observed on the first scan, and this persisted on the follow-up computed tomography. Two patients had persistent areas of mucoid impaction. In a third patient, mucus plugging was detected only on the second computed tomography. CONCLUSIONS: We conclude that there are many abnormalities on the high resolution computed tomography of patients with persistent asthma. Changes suggestive of bronchiectasis, namely bronchial dilatation, frequently resolve spontaneously. Therefore, the diagnosis of bronchiectasis by high resolution computed tomography in asthmatic patients must be made with caution, since bronchial dilatation can be reversible or can represent false dilatation. Nonsmoking chronic asthmatic subjects in this study had no evidence of centrilobular or panacinar emphysema.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To report the experience of a radiology department in the use of computed tomography - guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. METHODS: This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). RESULTS: In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. CONCLUSION: The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Body composition analysis is relevant to characterize the nutritional requirements and finishing phase of fish. The aim of this study was to investigate the relationship between ichthyometric (weight, total and standard length, density and yields), bromatological (fat, protein, ash and water content) and bioelectrical-impedance-analysis (BIA) (resistance, reactance, phase angle and composition indexes) variables in the hybrid tambatinga (Colossoma macropomum × Piaractus brachypomus). In a non-fertilized vivarium, 520 juveniles were housed and fed commercial rations. Then, 136 days after hatching (DAH), 15 fish with an average weight of 37.69 g and average total length of 12.96 cm were randomly chosen, anesthetized (eugenol) and subjected to the first of fourteen fortnightly assessments (BIA and biometry). After euthanasia, the following parts were weighed: whole carcass with the head, fillet, and skin (WC); fillet with skin (FS); and the remainder of the carcass with the head (CH). Together, FS and CH were ground and homogenized for the bromatological analyses. Estimates of the body composition and yields of tambatinga, with models including ichthyometric and BIA variables, showed correlation coefficients ranging from 0.81 (for the FS yield) to 1,00 (for the total ash). Similarly, models that included only BIA variables had correlation coefficients ranging from 0.81 (FS and CH yields) to 0.98 (for the total ash). Therefore, in tambatinga, the BIA technique allows the estimation of the yield of the fillet with skin and the body composition (water content, fat, ash, and protein). The best models combine ichthyometric and BIA variables.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mucoceles are cystic masses that generally affect the sinuses. It occurs as a result from obstruction of the ostium of a sinus and consequential accumulation of mucus. Frontal and ethmoid sinuses are mostly affected. Usually, the clinical symptoms are insidious, varying with the extent of the affected region. The treatment is surgical and endoscopic surgery is the method of choice in most cases. The present study is aimed at describing the main characteristics of paranasal sinuses mucoceles, demonstrating and illustrating a series of atypical presentations with emphasis on imaging findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Gastrointestinal bleeding represents a common medical emergency, with considerable morbidity and mortality rates, and a prompt diagnosis is essential for a better prognosis. In such a context, endoscopy is the main diagnostic tool; however, in cases where the gastrointestinal hemorrhage is massive, the exact bleeding site might go undetected. In addition, a trained professional is not always present to perform the procedure. In an emergency setting, optical colonoscopy presents limitations connected with the absence of bowel preparation, so most of the small bowel cannot be assessed. Scintigraphy cannot accurately demonstrate the anatomic location of the bleeding and is not available at emergency settings. The use of capsule endoscopy is inappropriate in the acute setting, particularly in the emergency department at night, and is a highly expensive method. Digital angiography, despite its high sensitivity, is invasive, presents catheterization-related risks, in addition to its low availability at emergency settings. On the other hand, computed tomography angiography is fast, widely available and minimally invasive, emerging as a promising method in the diagnostic algorithm of these patients, being capable of determining the location and cause of bleeding with high accuracy. Based on a critical literature review and on their own experience, the authors propose a computed tomography angiography protocol to assess the patient with gastrointestinal bleeding.