30 resultados para Electric wiring -- Equipment and supplies
em Scielo Saúde Pública - SP
Resumo:
ABSTRACT OBJECTIVE To estimate the prevalence of hypertension among adolescent Brazilian students. METHODS A systematic review of school-based cross-sectional studies was conducted. The articles were searched in the databases MEDLINE, Embase, Scopus, LILACS, SciELO, Web of Science, CAPES thesis database and Trip Database. In addition, we examined the lists of references of relevant studies to identify potentially eligible articles. No restrictions regarding publication date, language, or status applied. The studies were selected by two independent evaluators, who also extracted the data and assessed the methodological quality following eight criteria related to sampling, measuring blood pressure, and presenting results. The meta-analysis was calculated using a random effects model and analyses were performed to investigate heterogeneity. RESULTS We retrieved 1,577 articles from the search and included 22 in the review. The included articles corresponded to 14,115 adolescents, 51.2% (n = 7,230) female. We observed a variety of techniques, equipment, and references used. The prevalence of hypertension was 8.0% (95%CI 5.0–11.0; I2 = 97.6%), 9.3% (95%CI 5.6–13.6; I2 = 96.4%) in males and 6.5% (95%CI 4.2–9.1; I2 = 94.2%) in females. The meta-regression failed to identify the causes of the heterogeneity among studies. CONCLUSIONS Despite the differences found in the methodologies of the included studies, the results of this systematic review indicate that hypertension is prevalent in the Brazilian adolescent school population. For future investigations, we suggest the standardization of techniques, equipment, and references, aiming at improving the methodological quality of the studies.
Resumo:
The most preferred containers by Aedes aegypti were studied April and July (rainy and dry periods) in two Manaus neighbourhoods. In all, 2,700 premises and 13,912 containers were examined, most (87%) recorded outdoors. Out of the 13,100 inspected premises, only 1.6% showed to be positive for Aedes aegypti, summing up to 7,916 collected samples. Most frequently found containers outdoors in either neighbourhood regardless of rain or dry period were Bottles flasks and Storage, and indoors, Fixed, Flowerpots, and buckets. Productivity was estimated according to the number of premises and positive containers investigated, showing the actual container groups productivity. Considering both rainy and dry periods outdoors at Praça 14 the groups of Tyre, Flask, Bottle, Construction Equipment and Fixed, had the highest averages respectively. Construction Equipment and Flask groups were the most productive in Coroado in April. Flask, Construction Equipment and Storage groups stood out in July.
Electrocardiographic and Blood Pressure Alterations During Electroconvulsive Therapy in Young Adults
Resumo:
OBJECTIVE - To study cardiovascular alterations in young patients with no apparent organic disease who underwent electroconvulsive therapy. METHODS - The study comprised 47 healthy patients (22 males and 25 females) with a mean age of 30.3 years, who underwent electroconvulsive therapy. Ambulatory blood pressure monitoring and continuous electrocardiographic monitoring (Holter monitor) were performed during 24 hours. Blood pressure and heart rate were assessed 4 hours prior to electric shock administration, during electric shock administration, and 3 hours after electric shock administration. Arrhythmias and alterations in the ST segment in 24 hours were recorded. RESULTS - On electroconvulsive therapy, a significant increase in blood pressure and heart rate was observed and the measurements returned to basal values after 25 minutes. Three females had tracings with depression of the ST segment suggesting myocardial ischemia prior to and after electroconvulsive therapy. Coronary angiography was normal. No severe cardiac arrhythmias were diagnosed. CONCLUSION - 1) Electroconvulsive therapy is a safe therapeutic modality in psychiatry; 2) it causes a significant increase in blood pressure and heart rate; 3) it may be associated with myocardial ischemia in the absence of coronary obstructive disease; 4) electroconvulsive therapy was not associated with the occurrence of severe cardiac arrhythmias.
Resumo:
Objective To analyze the direct cost of reusable and disposable aprons in a public teaching hospital. Method Cross-sectional study of quantitative approach, focusing on the direct cost of reusable and disposable aprons at a teaching hospital in northern Paraná. The study population consisted of secondary data collected in reports of the cost of services, laundry, materials and supplies division of the institution for the year 2012 Results We identified a lower average cost of using disposable apron when compared to the reusable apron. The direct cost of reusable apron was R$ 3.06, and the steps of preparation and washing were mainly responsible for the high cost, and disposable apron cost was R$ 0.94. Conclusion The results presented are important for hospital managers properly allocate resources and manage costs in hospitals .
Resumo:
Objective The present study was aimed at estimating the doses received by physicians and patients during cerebral angiography procedures in a public hospital of Recife, PE, Brazil. Materials and Methods The study sample included 158 adult patients, and during the procedures the following parameters were evaluated: exposure parameters (kV, mAs), number of acquired images, reference air kerma value (Ka,r) and air kerma-area product (PKA). Additionally, the physicians involved in the procedures were evaluated as for absorbed dose in the eyes, thyroid, chest, hands and feet. Results The results demonstrated that the doses to the patients' eyes region were relatively close to the threshold for cataract occurrence. As regards the physicians, the average effective dose was 2.6 µSv, and the highest effective dose recorded was 16 µSv. Conclusion Depending on the number of procedures, the doses received by the physicians may exceed the annual dose limit for the crystalline lenses (20 mSv) established by national and international standards. It is important to note that the high doses received by the physicians are due to the lack of radiation protection equipment and accessories, such as leaded curtains, screens and protective goggles.
Resumo:
The objective of this study was to model mathematically and to simulate the dynamic behavior of an auger-type fertilizer applicator (AFA) in order to use the variable-rate application (VRA) and reduce the coefficient of variation (CV) of the application, proposing an angular speed controller θ' for the motor drive shaft. The input model was θ' and the response was the fertilizer mass flow, due to the construction, density of fertilizer, fill factor and the end position of the auger. The model was used to simulate a control system in open loop, with an electric drive for AFA using an armature voltage (V A) controller. By introducing a sinusoidal excitation signal in V A with amplitude and delay phase optimized and varying θ' during an operation cycle, it is obtained a reduction of 29.8% in the CV (constant V A) to 11.4%. The development of the mathematical model was a first step towards the introduction of electric drive systems and closed loop control for the implementation of AFA with low CV in VRA.
Resumo:
Methods previously described by Canovai et al. (Caryologia 47: 241-247, 1994) which produced C and ASG bands in mitotic chromosomes of Ceratitis capitata were applied to the chromosomes of several Anastrepha species. Metaphase plate yield was substantially increased by use of imaginal disks together with cerebral ganglia. The C-bands were quite prominent allowing the resolution of tiny blocks of heterochromatin. The ASG method produced G-like banded chromosomes, which permitted recognition of each individual chromosome. These simple techniques do not require special equipment and may be valuable for karyotype variability studies in fruit flies and other Diptera
Resumo:
The objective of the present study was to develop a simplified low cost method for the collection and fixation of pediatric autopsy cells and to determine the quantitative and qualitative adequacy of extracted DNA. Touch and scrape preparations of pediatric liver cells were obtained from 15 cadavers at autopsy and fixed in 95% ethanol or 3:1 methanol:acetic acid. Material prepared by each fixation procedure was submitted to DNA extraction with the Wizard® genomic DNA purification kit for DNA quantification and five of the preparations were amplified by multiplex PCR (azoospermia factor genes). The amount of DNA extracted varied from 20 to 8,640 µg, with significant differences between fixation methods. Scrape preparation fixed in 95% ethanol provided larger amount of extracted DNA. However, the mean for all groups was higher than the quantity needed for PCR (50 ng) or Southern blot (500 ng). There were no qualitative differences among the different material and fixatives. The same results were also obtained for glass slides stored at room temperature for 6, 12, 18 and 24 months. We conclude that touch and scrape preparations fixed in 95% ethanol are a good source of DNA and present fewer limitations than cell culture, tissue paraffin embedding or freezing that require sterile material, culture medium, laboratory equipment and trained technicians. In addition, they are more practical and less labor intensive and can be obtained and stored for a long time at low cost.
Resumo:
Few studies are available concerning correlations between pulse oximetry and peak expiratory flow in children and adolescents with acute asthma. Although the Global Initiative for Asthma states that measurements of lung function and oximetry are critical for the assessment of patients, it is not clear if both methods should necessarily be included in their evaluation. Since there is a significant difference in cost between pulse oximetry equipment and peak expiratory flow devices, we determined whether clinical findings and peak expiratory flow measurements are sufficient to determine the severity of acute asthma. The present prospective observational study was carried out to determine if there is correlation between pulse oximetry and peak expiratory flow determination in 196 patients with acute asthma aged 4 to 15 years diagnosed according to the Global Initiative for Asthma criteria. Patients experiencing their first or second wheezing episode, with fever, related acute or chronic diseases, and unable to perform the peak expiratory flow maneuver were excluded. Measurements of peak expiratory flow and pulse oximetry were performed at admission and after 15 min of each inhaled salbutamol cycle. Correlations obtained by linear regression using the Pearson correlation coefficients (r) were 0.41 (P < 0.0001), 0.53 (P < 0.0001), 0.51 (P < 0.0001), and 0.61 (P < 0.0001) at admission and after the first, second and third cycles of salbutamol, respectively. These correlations showed that one measure cannot substitute the other (Pearson's coefficient <0.7), probably because they evaluate different aspects in the airways, suggesting that peak expiratory flow should not be used alone in the assessment of acute asthma in children and adolescents.
Resumo:
Biofilms in milk cooling tanks compromise product quality even on farms. Due to the lack of studies of this topic, this study evaluated the microbiological conditions of raw milk cooling tanks on farms and characterized the microorganisms isolated from these tanks. Samples were wiped off with sterile swabs from seven milk cooling tanks in three different points in each tank. Mesophiles and psychrotrophic counts were performed in all samples. The isolation of Pseudomonas spp., Bacillus cereus and atypical colonies formed on selective media were also performed, totalizing 297 isolates. All isolates were tested for protease and lipase production and biofilm formation. Of the total isolates, 62.9% produced protease, 55.9% produced lipase, and 50.2% produced biofilm. The most widespread genus inside the milk cooling tank was Pseudomonas since it was not possible to associate this contamination with a single sampling point in the equipment. High counts of microorganisms were found in some cooling tanks, indicating poor cleaning of the equipment and providing strong evidences of microbial biofilm presence. Moreover, it is worth mentioning the milk potential contamination with both microbial cells and their degrading enzymes, which compromises milk quality.
Resumo:
A Dot enzyme-linked immunosorbent assay (Dot-ELISA) was standardized and evaluated for the serodiagnosis of human toxoplasmosis. Out of 538 serum samples tested by the immunofluorescence test for toxoplasmosis (IFAT-IgG) as reference test, 183 (34%) were positive at cut off 1:16 and 192 (36%) were positive for Dot-ELISA-IgG at cut-off 1:256. For Dot-ELISA, co-positivity was 0.94, co-negativity 0.94 and concordance 0.88 in relation to IFAT-IgG. These results suggest the usefulness of Dot-ELISA (cut-off titer of 1:256) for the serodiagnosis of human toxoplasmosis. The main advantage of this technique is simplicity, positive test can be visually identified (colored precipitate). It does not require a special equipment and it can be used as a qualitative test to screen large numbers of samples or as a quantitative assay to determine end-point titration of individual sera.
Resumo:
There is no paucity of methods for diagnosing Cryptosporidium spp. infection. The merits of immunoassays notwithstanding, microscopic identification of Cryptosporidium spp. oocysts in fecal samples remains an important diagnostic procedure. It owes the persistence of its use to such characteristics as dispensing with expensive equipment and kits, requiring only basic laboratory facilities, and having a low probability of false positive results when permanent slides are prepared, which can be re-examined in case of doubt. Cryptosporidium spp. oocysts can be readily identified in fecal smears prepared according to a regressive iron hematoxylin staining technique. The number of steps and their duration, as well as costs, were reduced to a minimum without loss of image quality and permanence of the preparations.
Resumo:
The present study was carried out to evaluate the Malar-CheckTM Pf test, an immunochromatographic assay that detects Plasmodium falciparum Histidine Rich Protein II, does not require equipment, and is easy and rapid to perform. In dilution assays performed to test sensitivity against known parasite density, Malar-CheckTMwere compared with thick blood smear (TBS), the gold standard for diagnosis. Palo Alto isolate or P. falciparum blood from patients with different parasitemias was used. The average cut-off points for each technique in three independent experiments were 12 and 71 parasites/mm³ (TBS and Malar-CheckTM, respectively). In the field assays, samples were collected from patients with fever who visited endemic regions. Compared to TBS, Malar-CheckTMyielded true-positive results in 38 patients, false-positive results in 3, true-negative results in 23, and false-negative result in 1. Malar-CheckTMperformed with samples from falciparum-infected patients after treatment showed persistence of antigen up to 30 days. Malar-CheckTM should aid the diagnosis of P. falciparum in remote areas and improve routine diagnosis even when microscopy is available. Previous P. falciparum infection, which can determine a false-positive test in cured individuals, should be considered. The prompt results obtained with the Malar-CheckTM for early diagnosis could avoid disease evolution to severe cases.
Resumo:
A rapid test based on an immunochromatography assay - Determine Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.
Resumo:
We describe a simple method using percoll gradient for isolation of highly enriched human monocytes. High numbers of fully functional cells are obtained from whole blood or buffy coat cells. The use of simple laboratory equipment and a relatively cheap reagent makes the described method a convenient approach to obtaining human monocytes.