31 resultados para ET AAS
em Scielo Saúde Pública - SP
Resumo:
The aim of this work was to compare the performances of the L'vov and integrated platforms in order to overcome the interferences found on lead determination in zidovudine by ET AAS. Pyrolysis and atomization temperatures found with integrated platform were 700 and 1400°C, respectively. The characteristic masses were 12.7 ± 1.2 pg with integrated platform and 11.1 ± 1.3 pg with grooved platform. The ratio between the slopes of zidovudine and aqueous curves shows a decrease in the interferences when the L'vov platform is used (bAZT/b aq = 0.97 ± 0.10) and the detection limit found was 0.03 µg.g-1. That ratio was 0.85 ± 0.07 with the integrated platform.
Resumo:
A procedure for the simultaneous determination of Cr, Ni, and V in urine by electrothermal atomic absorption spectrometry (ET AAS) was optimized by factorial design, and performed at a pyrolysis and atomization temperatures of 1300 and 2500 ºC, respectively, using 15 µg de Mg(NO3)2 as chemical modifier. Characteristics mass of 14, 6 and 220 ρg and detection limits of the method of 0.07, 0.38 and 0.75 µg L-1 were obtained for Cr, Ni and V respectively. The methodology was validated using a Liphochek Urine Metals Control sample (Bio-Rad) (P=0.05). The methodology was applied to samples of voluntary Venezuelan people, not environmentally exposed to specific emissions, and results ranging from < LOD-1.1 and 1.3-3.3 µg L-1 was observed for Cr and V, respectively, and not detectable levels for Ni.
Resumo:
The use of an internal standard (IS) in ET AAS can be considered a new trend after the commercial introduction of a simultaneous spectrometer. The evaluation of experimental data to choose the most appropriate IS can be done by comparing correlation graphs. They were used to verify the resemblance among the simultaneous measurements obtained for the analyte(s) and the IS by inductively coupled plasma optical emission spectrometry (ICPOES). The judicious selection of IS by using correlation graphs for determinations by ET AAS can be exploited to improve the precision and accuracy of the analytical results. Therefore, a new approach for studying the use of IS in ET AAS is presented.
Resumo:
The spatial and temporal retention of metals has been studied in water and sediments of the Gavião River, Anagé and Tremedal Reservoirs, located in the semi-arid region, Bahia - Brazil, in order to identify trends in the fluxes of metals from the sediments to the water column. The determination of metals was made by ICP OES and ET AAS. The application of statistical methods showed that this aquatic system presents suitable conditions to move Cd2+ and Pb2+ from the water column to the sediment.
Resumo:
OBJETIVO: objetivo desta pesquisa foi investigar o grau de satisfação entre os usuários de Aparelho de Amplificação Sonora (AAS) de tecnologia analógica e digital. FORMA DE ESTUDO: clínico com coorte transversal. MATERIAL E MÉTODO: A amostra foi constituída de 40 usuários de AAS unilateral, sendo 20 de tecnologia analógica (Grupo I) e 20 de tecnologia digital (Grupo II). Os indivíduos são portadores de perda auditiva neurossensorial, de configuração plana, de grau leve a moderado, com idade entre 40 e 95 anos. O instrumento de avaliação utilizado foi o International Outcome Inventory for Hearing Aids (IOI-HA - Versão em Português) proposto por Cox et al. (2002). RESULTADOS: Os resultados mostraram que os usuários do Grupo II utilizam o AAS por mais tempo diariamente e também apresentam um grau de dificuldade menor em determinadas situações com o uso da amplificação, comparado aos usuários do Grupo I. Os usuários do Grupo II relatam que sua perda auditiva não afeta em nada sua relação com terceiros. CONCLUSÃO: Apesar de os resultados revelarem que os usuários do Grupo I apresentam um handicap auditivo mais acentuado comparado aos usuários do Grupo II, o grau de satisfação com relação à amplificação não apresenta diferença significativa entre os dois grupos.
Resumo:
A eficiência do uso de uma alça metálica para a remoção de elementos parasitários flutuantes foi investigada. A quantidade de elementos removidos a cada alçada sucessiva foi confrontada com um modelo logarítmico, o qual indicou que cada alçada retirou cerca de 30% dos elementos parasitários flutuantes remanescentes. Estimou-se que as 5 primeiras alçadas retiraram um total de 83% dos elementos parasitários flutuantes, sendo este um procedimento adequado para o método sob investigação.