144 resultados para ELECTROPHORESIS METHOD
em Scielo Saúde Pública - SP
Resumo:
This paper describes the analytical methods for determination of total chlorogenic acid (CGA) and their individual isomers. Spectrofotometric methods are adequate for total CGA analysis in green coffee but they can provide inflated results for coffee products. High pressure liquid chromatography (HPLC) with gel permeation column and ultraviolet (UV) monitoring is adequate for the simultaneous analysis of total CGA, alkaloids and sugars in coffee products. HPLC-UV-reversed phase is a simple, rapid and precise method for the determination of the individual isomers of CGA. Gas chromatography (GC) also is applied to the analysis of the individual isomers but phenolic acids need to be derivatized before analysis. Both HPLC- and GC-mass spectrometry provide an unequivocal identification of the individual isomers. The capillary electrophoresis method is simple, rapid and adequate to the simultaneous analysis of polyphenols and xanthines. Advantages and limitations of each method are discussed throughout the text.
Resumo:
We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination
Resumo:
Rotavirus has been considered the main agent of infectious diarrhea especially among younger children. We addressed the prevalence of rotavirus-associated diarrhea and the diversity of circulating electropherotypes by immunochromatography and RNA electrophoresis. Stool samples were taken from 391 children (267 with diarrhea) from the lower socioeconomic stratum who sought treatment in the Hospital Infantil João Paulo II/Belo Horizonte, during 2005 and 2006. Rotavirus was detected in 79/20.2% of subjects, 64/24.0% with diarrhea and 15/12.1% with no diarrhea. The virus was strongly associated with diarrhea (p = 0.003). A total of 76/19.4% and 69/17.6% rotavirus-positive children were identified by immunochromatography and electrophoresis, respectively. Rotavirus-associated diarrhea was more frequently detected in dry months (p < 0.001) and almost exclusively in children aged up to three years. Long profile strains prevailed (54/78.3%) but a shift toward short electropherotype was identified. Despite the decrease seen in 2006, rotavirus infection is still very common in our area. Although viral RNA electrophoresis is useful as a typing method, it should not be used exclusively in the diagnosis of rotavirus infection. We confirmed a shift from long to short profile strains, as already described for other South American countries.
Resumo:
A simple, quick and sensitive method was used to detect telomerase activity in Plasmodium falciparum. The telomeric repeat amplification protocol (TRAP assay) was modified using electrophoresis and staining with SYBR-green I to detect telomerase activity in a range of 10² to 10(7) parasites. This might be a useful way to ascertain telomerase activity in different types of nontumor cells.
Resumo:
In the current study, an alternative method has been proposed for simultaneous analysis of palmitic, stearic, oleic, linoleic, and linolenic acids by capillary zone electrophoresis (CZE) using indirect detection. The background electrolyte (BGE) used for the analysis of these fatty acids (FAs) consisted of 15.0 mmol L−1 NaH2PO4/Na2HPO4 at pH 6.86, 4.0 mmol L−1 SDBS, 8.3 mmol L−1 Brij 35, 45% v/v acetonitrile (can), and 2.1% n-octanol. The FAs quantification of FAs was performed using a response factor approach, which provided a high analytical throughput for the real sample. The CZE method, which was applied successfully for the analysis of pequi pulp, has advantages such as short analysis time, absence of lipid fraction extraction and derivatization steps, and no significant difference in the 95% confidence intervals for FA quantification results, compared to the gas chromatography official method (AOCS Ce 1h-05).
Resumo:
Capillary electrophoresis (CE) with capacitively coupled contactless conductivity detection (C4D) was used for determination of sodium and potassium concentrations in diet and non-diet soft drinks. Higher sodium concentrations were found in the diet samples due to the utilization of sodium salts of cyclamate and saccharine as sweeteners. The CE-C4D method can be used by food industries and health regulatory agencies for monitoring sodium and potassium content, not only in soft drink but in many others food products.
Resumo:
Decaffeinated coffee accounts for 10 percent of coffee sales in the world; it is preferred by consumers that do not wish or are sensitive to caffeine effects. This article presents an analytical comparison of capillary electrophoresis (CE) and high performance liquid chromatography (HPLC) methods for residual caffeine quantification in decaffeinated coffee in terms of validation parameters, costs, analysis time, composition and treatment of the residues generated, and caffeine quantification in 20 commercial samples. Both methods showed suitable validation parameters. Caffeine content did not differ statistically in the two different methods of analysis. The main advantage of the high performance liquid chromatography (HPLC) method was the 42-fold lower detection limit. Nevertheless, the capillary electrophoresis (CE) detection limit was 115-fold lower than the allowable limit by the Brazilian law. The capillary electrophoresis (CE) analyses were 30% faster, the reagent costs were 76.5-fold, and the volume of the residues generated was 33-fold lower. Therefore, the capillary electrophoresis (CE) method proved to be a valuable analytical tool for this type of analysis.
Resumo:
This study aimed to evaluate the efficiency of multiple centroids to study the adaptability of alfalfa genotypes (Medicago sativa L.). In this method, the genotypes are compared with ideotypes defined by the bissegmented regression model, according to the researcher's interest. Thus, genotype classification is carried out as determined by the objective of the researcher and the proposed recommendation strategy. Despite the great potential of the method, it needs to be evaluated under the biological context (with real data). In this context, we used data on the evaluation of dry matter production of 92 alfalfa cultivars, with 20 cuttings, from an experiment in randomized blocks with two repetitions carried out from November 2004 to June 2006. The multiple centroid method proved efficient for classifying alfalfa genotypes. Moreover, it showed no unambiguous indications and provided that ideotypes were defined according to the researcher's interest, facilitating data interpretation.
Resumo:
A brief description of the main features of the health planning technique developed by the "Centro de Estudios del Desarrollo" (CENDES) in Venezuela, and proposed by the Pan-American Health Organization for use in Latin America, is presented. This presentation is followed by an appraisal of the planning method which includes comments both upon its positive aspects and upon its negative points. Comments are also made referring to other recent publications of the WHO/PAHO on health planning. In conclusion, the CENDES technique is considered a health planning method of great potential for use especially in underdeveloped areas, the success of its application depending upon the hability of the health planners to introduce the necessary modifications to adapt to the local circunstamces.
Resumo:
An alternative vector control method, using lambda-cyhalothrin impregnated wide-mesh gauze covering openings in the walls of the houses was developed in an area in the Eastern part of the interior of Suriname. Experimental hut observations showed that Anopheles darlingi greatly reduced their biting activity (99-100%) during the first 5 months after impregnation. A model assay showed high mortality both of mosquitoes repelled by the gauze as well as of those that succeeded in getting through it. A field application test in 270 huts showed good acceptance by the population and good durability of the applied gauze. After introducing the method in the entire working area, replacing DDT residual housespraying, the malaria prevalence, of 25-37% before application dropped and stabilized at between 5 and 10% within one year. The operational costs were less than those of the previously used DDT housespraying program, due to a 50% reduction in the cost of materials used. The method using widemesh gauze impregnated with lambdacyhalothrin strongly affects the behavior of An. darlingi. It is important to examine the effect of the method on malaria transmission further, since data indirectly obtained suggest substantial positive results.
Resumo:
OBJECTIVE To propose a method of redistributing ill-defined causes of death (IDCD) based on the investigation of such causes.METHODS In 2010, an evaluation of the results of investigating the causes of death classified as IDCD in accordance with chapter 18 of the International Classification of Diseases (ICD-10) by the Mortality Information System was performed. The redistribution coefficients were calculated according to the proportional distribution of ill-defined causes reclassified after investigation in any chapter of the ICD-10, except for chapter 18, and used to redistribute the ill-defined causes not investigated and remaining by sex and age. The IDCD redistribution coefficient was compared with two usual methods of redistribution: a) Total redistribution coefficient, based on the proportional distribution of all the defined causes originally notified and b) Non-external redistribution coefficient, similar to the previous, but excluding external causes.RESULTS Of the 97,314 deaths by ill-defined causes reported in 2010, 30.3% were investigated, and 65.5% of those were reclassified as defined causes after the investigation. Endocrine diseases, mental disorders, and maternal causes had a higher representation among the reclassified ill-defined causes, contrary to infectious diseases, neoplasms, and genitourinary diseases, with higher proportions among the defined causes reported. External causes represented 9.3% of the ill-defined causes reclassified. The correction of mortality rates by the total redistribution coefficient and non-external redistribution coefficient increased the magnitude of the rates by a relatively similar factor for most causes, contrary to the IDCD redistribution coefficient that corrected the different causes of death with differentiated weights.CONCLUSIONS The proportional distribution of causes among the ill-defined causes reclassified after investigation was not similar to the original distribution of defined causes. Therefore, the redistribution of the remaining ill-defined causes based on the investigation allows for more appropriate estimates of the mortality risk due to specific causes.
Resumo:
One of the main difficulties related to the detection of the Hepatitis Delta Virus (HDV) antigen and antibody has been the source of the needed HD antigen since HDV containing human and animal livers are very difficult to obtain and since yield is low. This fact prompted us to try to use the serum of patients in the acute phase of HDV infection as a source of HDAg and turn to enzyme immunoassays (EIA) instead of RIA for the sake of easiness and economy in the amount of HDAg needed. The antigen for EIA was obtained from patients during the acute phase of HDV infection and the antibody from patients who have been carriers for many years. For the detection of the antigen, a sandwich type method was employed, whereas for the antibody a competition assay was developed. In order to assess the relative specificity and sensibility of the test, the antibody assay was compared to a commercial RIA (C. RIA, Abbott) and to a non-commercial RIA (NC RIA). Forty-two sera were tested by the two methods and only in two cases discrepant results were obtained. Its is concluded that: 1) sera from patients in the acute and chronic phases of HDV infection can be used as source of both antigen and antibody, for immunoassays; 2) EIA and RIA have comparable relative specificity and sensibility and 3) EIA is easier to perform, cheaper, non-hazardous, has a longer shelf-life and saves scarce HDAg.
Resumo:
A low cost method (LCM) to produce a gaseous environment for the isolation of Helicobacter pylori, was compared with the standard Gas Park system. The LCM uses a carbonated antacid tablet, a plastic bag with tap water, a candle, and a wide-mouthed glass jar provided with a tight-fitting metalic screw cap and a rubber gasket. Antral gastric biopsies from 153 cases were incubated by duplicate on blood agar plates and treated with the two methods. In 95 cases the agent was isolated from both, and only from the standard method in 10 cases; the opposite condition was found in five cases, and 43 were negative. That difference is not significant (Pearson's X²= 93.25 p > 0,05)