209 resultados para ELECTRON-CAPTURE DETECTION

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two models of a glass micro-extractor were constructed after modification of a model proposed in the literature. The two models were used for the simultaneous extraction and enrichment of organochlorinated pesticides from aqueous matrixes to an organic solution appropriate for the gas chromatographic analysis of the pesticide. It was established that the performance of one of the modified micro-extractors permits the pre-concentration of the pesticides to a level that allow their quantitation at the trace level with electron capture detection. It is thus concluded that the glass micro-extractor is a suitable tool for the sample preparation step in the gas chromatographic analysis of environmental pollutants of the class of pesticides.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The technique of solid phase microextraction (SPME) was used for the extraction of halogenated contaminants of water samples from three cities of the State of São Paulo and the extracts were submitted to gas chromatographic analysis with electron capture detection (GC-ECD). In the samples of water collected at the city of São Paulo the detected level of trihalomethanes (THM) expressed as the sum of chloroform, dibromochloromethane and dichlorobromomethane, were higher than the permissible limit established by the Brazilian regulation. In the samples collected at the two other cities the level of any of the three THM remained below the sensitivity of the ECD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The pyrethroids bifenthrin, permethrin, cypermethrin and deltamethrin were extracted by solid phase extraction (SPE) and solid phase microextraction (SPME). The analysis were performed on a gas chromatograph with electron capture detection (GC-ECD). Octadecil Silano-C18, Florisil and Silica stationary phases were studied for SPE. Better results were obtained for Florisil which gave recoveries from 80% to 108%. Pyrethroids extraction by SPME showed a linear response and a detection limit of 10 pg ml-1. Although the data showed that the two extraction methods were able to isolate the pesticide residues from water samples, the best results were obtained by using SPME which is more sensitive, faster, cheeper, being a more useful technique for the analysis of pyrethroids in drinking water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work the exposure of wells and surface water to pesticides, commonly used for tobacco cropping, was assessed. Water consumption wells and surface water flows were sampled at different times. After a preconcentration step with solid phase extraction (SPE), the selected pesticides were determined by gas chromatography with electron capture detection (GC-ECD) or high performance liquid chromatography with diode array detection (HPLC-DAD). No pesticides were detected in the well water samples and surface water flow in the winter season. However, in the spring and summer higher concentrations of chlorpyrifos and imidacloprid were found in the water source samples. Atrazine, simazine and clomazone were also found. The occurrence of pesticides in collected water samples was related with the application to tobacco.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analysis of seven pesticides in sediments was successfully achieved using comprehensive two-dimensional gas chromatography with micro-electron capture detection, as it provided higher sensitivity and less matrix interference. Repeatability and intermediate precision of peak areas and heights were less than 4% and the recovery percentage for the analytes ranged from 52 to 115%. Instrumental LOD and LOQ were in the range of 0.60 to 2.31 μg L-1 and 1.83 to 5.62 μg L-1, respectively. Concentrations of 3.34 μg kg-1 (dry basis) for trifloxystrobin and azoxystrobin (below the LOQ) were found in a sediment sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tobacco cultivation in shallow soils and steep landscape under intense use of agrochemicals contributes to environment degradation. In this study, we assessed the concentration of agrochemicals in draw wells used for human consumption and a creek in a small catchment predominantly cropped to tobacco. Chlorpyrifos, flumetralin, and iprodione were determined by gas chromatography with electron capture detection, while imidalcloprid, atrazine, simazine, and clomazone were quantified by high-performance liquid chromatography with UV detection. Considering all sampling sites, all agrochemicals were detected at least once, except for flumetralin. The occurrence of agrochemicals in tobacco crops is a consequence of their fast transfer to surface water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Difenoconazole residues in strawberry fruit cultivated in pots were estimated using the solid-liquid extraction with low temperature partition (SLE/LTP) method for sample preparation and gas chromatography with electron capture detection (GC/ECD) for analysis. The optimized method presented excellent recovery values from fortified samples and reproducibility (average recovery values ≥ 98%; CV values < 15%). Linearity of response was demonstrated (r = 0.995) with a detection limit of 9 µg kg-1. The method was successfully applied for the determination of difenoconazole residues in strawberries. Based on these results, the fungicide dissipates quickly, but the residual concentration increases after multiple applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for determination of organohalogen pesticides in strawberry by gas chromatography with electron capture detection was validated and applied in a monitoring program. Linearity, matrix effects, and day effect were evaluated for the analytes alpha-endosulfan, beta-endosulfan, endosulfan sulphate, lambda-cyhalothrin, procymidone, and trifluralin. The linear range varied according to the chromatographic response of the analyte. Significant matrix effects were observed. The mean recoveries ranged from 74.6 to 115.4%, with repeatability standard deviations between 1.6 and 21.0% and intermediate precision between 5.9 and 21.0%. Detection, quantification and decision limit, and detection capacity ranged from 0.003 to 0.007 mg/kg, 0.005 to 0.013 mg/kg; 0.003 to 3.128 mg/kg; and 0.005 to 3.266 mg/kg, respectively. The method was fit for the purpose of monitoring organohalogen residues in strawberries. Residues of these pesticides were detected in 124 of the 186 samples analyzed between 2009 and 2011 in the state of Minas Gerais. Nine of them did not comply with the current legislation requirements; among them, seven (3.8%) had residues of unauthorized pesticide for the culture of strawberry, one (0.5%) had residues above the maximum residue limit, and another one (0.5%) exhibited both non-conformities.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work the contamination, by organochlorinated, of a drinking water source located in the region of Viçosa, MG, was evaluated. The identification and quantification of the analytes was carried out using a gas-chromatograph equipped with an electron capture detector after liquid-liquid extraction and concentration. Four insecticides, Aldrin, Epoxy heptachloride, Endrin and op'- DDT were detected in concentrations that are higher than the safety limits established in the Brazilian legislation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The development of analytical methods for determination of eight pesticides of different chemical classes (trichlorfon, propanil, fipronil, propiconazole, trifloxystrobin, permethrin, difenoconazole and azoxystrobin) in sediments with gas chromatography-micro-electron capture detector (GC/µECD) and comprehensive two-dimensional gas chromatography with micro-electron capture detector (GCxGC/µECD) is described. These methods were applied to real sediment samples, and the best results were obtained using a 5% diphenyl-methylpolysiloxane column for 1D-GC. For GCxGC the same column was employed in the first dimension and a 50%-phenyl-methylpolysiloxane stationary phase was placed in the second dimension. Due to the superior peak capacity and selectivity of GCxGC, interfering matrix peaks were separated from analytes, showing a better performance of GCxGC.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A sensitive and specific Capture Sandwich ELISA (CSE) was developed using polyclonal purified rabbit antibodies against three different axenic strains of Entamoeba histolytica: CSP from Brazil and HM1 - IMSS from Mexico, for the detection of coproantigens in fecal samples. Immunoglobulin G (IgG) againstis E. histolytica was isolated from rabbits immunized with throphozoites whole extract in two stages: affinity chromatography in a column containing E. histolytica antigens bound to Sepharose 4B was followed by another chromatography in Sepharose antibodies 4B-Protein A. A Capture Sandwich ELISA using purified antibodies was able to detect 70ng of amebae protein, showing a sensitivity of 93% and specificity of 94%. The combination of microscopic examination and CSE gave a concordance and discordance of 93.25% and 6.75%, respectively. It was concluded that CSE is highly specific for the detection of coproantigens of E. histolytica in feces of infected patients, is quicker to perform, easier and more sensitive than microscopic examination.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction This study evaluated the level of concordance between hybrid capture II (HCII) and PapilloCheck® for the detection of high-risk human papillomavirus (HPV) in anal samples. Methods Anal cell samples collected from 42 human immunodeficiency virus (HIV)+ patients were analyzed. Results Considering only the 13 high-risk HPV types that are detectable by both tests, HCII was positive for 52.3% of the samples, and PapilloCheck® was positive for 52.3%. The level of concordance was 80.9% (Kappa = 0.61). Conclusions Good concordance was observed between the tests for the detection of high-risk HPV.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Transmission electon microscopy has been employed for the rapid detection of mycoplasma in sera and cell cultures. High speed centrifugation of sera or low speed centrifugation of cell debris, followed by negative staining of the resuspended pellet, detected mycoplasma contamination more frequently than a culture method followed by direct fluorescence (DAPI), which was used as a control procedure. The appearance of the mycoplasma cell border and content gives some information about particle viability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Print-capture (PC) Polymerase chain reaction (PCR) was evaluated as a novel detection method of plant viruses. Tomato (Lycopersicon esculentum) plants infected with begomovirus (fam. Geminiviridae, gen. Begomovirus) and viruliferous whiteflies were used to study the efficiency of the method. Print-capturing steps were carried out using non-charged nylon membrane or filter paper as the solid support for DNA printings. Amplified DNA fragments of expected size were consistently obtained by PCR from infected plants grown in a greenhouse, after direct application of printed materials to the PCR mix. However, virus detection from a single whitefly and from field-grown tomato samples required a high temperature treatment of printed material prior to PCR amplification. Comparison of nylon membrane and filter paper as the solid support revealed the higher efficiency of the nylon membrane. The application of print-capture PCR reduces the chances of false-positive amplification by reducing manipulation steps during preparation of the target DNA. This method maintains all the advantages of PCR diagnosis, such as the high sensitivity and no requirement of radioactive reagents.