19 resultados para Distance Corridor Walk
em Scielo Saúde Pública - SP
Resumo:
We assessed the 6-min walk distance (6MWD) and body weight x distance product (6MWw) in healthy Brazilian subjects and compared measured 6MWD with values predicted in five reference equations developed for other populations. Anthropometry, spirometry, reported physical activity, and two walk tests in a 30-m corridor were evaluated in 134 subjects (73 females, 13-84 years). Mean 6MWD and 6MWw were significantly greater in males than in females (622 ± 80 m, 46,322 ± 10,539 kg.m vs 551 ± 71 m, 36,356 ± 8,289 kg.m, P < 0.05). Four equations significantly overestimated measured 6MWD (range, 32 ± 71 to 137 ± 74 m; P < 0.001), and one significantly underestimated it (-36 ± 86 m; P < 0.001). 6MWD significantly correlated with age (r = -0.39), height (r = 0.44), body mass index (r = -0.24), and reported physical activity (r = 0.25). 6MWw significantly correlated with age (r = -0.21), height (r = 0.66) and reported physical activity (r = 0.25). The reference equation devised for walk distance was 6MWDm = 622.461 - (1.846 x Ageyears) + (61.503 x Gendermales = 1; females = 0); r2 = 0.300. In an additional group of 85 subjects prospectively studied, the difference between measured and the 6MWD predicted with the equation proposed here was not significant (-3 ± 68 m; P = 0.938). The measured 6MWD represented 99.6 ± 11.9% of the predicted value. We conclude that 6MWD and 6MWw variances were adequately explained by demographic and anthropometric attributes. This reference equation is probably most appropriate for evaluating the exercise capacity of Brazilian patients with chronic diseases.
Resumo:
INTRODUCTION: To evaluate physical capacity as determined by the six-minute walk test (6MWT) in patients with chronic heart failure due to Chagas' disease associated with systemic arterial hypertension (Chagas-SAH). METHODS: A total of 98 patients routinely followed at the Cardiomyopathy Outpatient Service were recruited. Of these, 60 (61%) were diagnosed with Chagas disease and 38 (39%) with Chagas-SAH. RESULTS: The distance walked during 6 min was 357.9 ±98 m for Chagas-SAH patients and 395.8 ± 121m for Chagas cardiomyopathy patients (p >0.05). In patients with Chagas-SAH, a negative correlation occurred between the 6MWT and the total score of the Minnesota Living with Heart Failure Questionnaire (r= -0.51; p=0.001). No other correlations were determined between 6MWT values and continuous variables in patients with Chagas-SAH. CONCLUSIONS: The results of the 6MWT in Chagas-SAH patients are similar to those verified in Chagas cardiomyopathy patients with chronic heart failure. Coexistence of SAH does not seem to affect the functional capacity of Chagas cardiomyopathy patients with chronic heart failure.
Resumo:
OBJECTIVE: The 6-minute walk test is an way of assessing exercise capacity and predicting survival in heart failure. The 6-minute walk test was suggested to be similar to that of daily activities. We investigated the effect of motivation during the 6-minute walk test in heart failure. METHODS: We studied 12 males, age 45±12 years, ejection fraction 23±7%, and functional class III. Patients underwent the following tests: maximal cardiopulmonary exercise test on the treadmill (max), cardiopulmonary 6-minute walk test with the walking rhythm maintained between relatively easy and slightly tiring (levels 11 and 13 on the Borg scale) (6EB), and cardiopulmonary 6-minute walk test using the usual recommendations (6RU). The 6EB and 6RU tests were performed on a treadmill with zero inclination and control of the velocity by the patient. RESULTS: The values obtained in the max, 6EB, and 6RU tests were, respectively, as follows: O2 consumption (ml.kg-1.min-1) 15.4±1.8, 9.8±1.9 (60±10%), and 13.3±2.2 (90±10%); heart rate (bpm) 142±12, 110±13 (77±9%), and 126±11 (89±7%); distance walked (m) 733±147, 332±66, and 470±48; and respiratory exchange ratio (R) 1.13±0.06, 0.9±0.06, and 1.06±0.12. Significant differences were observed in the values of the variables cited between the max and 6EB tests, the max and 6RU tests, and the 6EB and 6RU tests (p<0.05). CONCLUSION: Patients, who undergo the cardiopulmonary 6-minute walk test and are motivated to walk as much as they possibly can, usually walk almost to their maximum capacity, which may not correspond to that of their daily activities. The use of the Borg scale during the cardiopulmonary 6-minute walk test seems to better correspond to the metabolic demand of the usual activities in this group of patients.
Resumo:
The 6-minute walk test (6MWT) is a simple field test that is widely used in clinical settings to assess functional exercise capacity. However, studies with healthy subjects are scarce. We hypothesized that the 6MWT might be useful to assess exercise capacity in healthy subjects. The purpose of this study was to evaluate 6MWT intensity in middle-aged and older adults, as well as to develop a simple equation to predict oxygen uptake ( V ˙ O 2 ) from the 6-min walk distance (6MWD). Eighty-six participants, 40 men and 46 women, 40-74 years of age and with a mean body mass index of 28±6 kg/m2, performed the 6MWT according to American Thoracic Society guidelines. Physiological responses were evaluated during the 6MWT using a K4b2 Cosmed telemetry gas analyzer. On a different occasion, the subjects performed ramp protocol cardiopulmonary exercise testing (CPET) on a treadmill. Peak V ˙ O 2 in the 6MWT corresponded to 78±13% of the peak V ˙ O 2 during CPET, and the maximum heart rate corresponded to 80±23% of that obtained in CPET. Peak V ˙ O 2 in CPET was adequately predicted by the 6MWD by a linear regression equation: V ˙ O 2 mL·min-1·kg-1 = -2.863 + (0.0563×6MWDm) (R2=0.76). The 6MWT represents a moderate-to-high intensity activity in middle-aged and older adults and proved to be useful for predicting cardiorespiratory fitness in the present study. Our results suggest that the 6MWT may also be useful in asymptomatic individuals, and its use in walk-based conditioning programs should be encouraged.
Resumo:
Background:Isolated congenital atrioventricular block (CAVB) is a rare condition with multiple clinical outcomes. Ventricular remodeling can occur in approximately 10% of the patients after pacemaker (PM) implantation.Objectives:To assess the functional capacity of children and young adults with isolated CAVB and chronic pacing of the right ventricle (RV) and evaluate its correlation with predictors of ventricular remodeling.Methods:This cross-sectional study used a cohort of patients with isolated CAVB and RV pacing for over a year. The subjects underwent clinical and echocardiographic evaluation. Functional capacity was assessed using the six-minute walk test. Chi-square test, Fisher's exact test, and Pearson correlation coefficient were used, considering a significance level of 5%.Results:A total of 61 individuals were evaluated between March 2010 and December 2013, of which 67.2% were women, aged between 7 and 41 years, who were using PMs for 13.5 ± 6.3 years. The percentage of ventricular pacing was 97.9 ± 4.1%, and the duration of the paced QRS complex was 153.7 ± 19.1 ms. Majority of the subjects (95.1%) were asymptomatic and did not use any medication. The mean distance walked was 546.9 ± 76.2 meters and was strongly correlated with the predicted distance (r = 0.907, p = 0.001) but not with risk factors for ventricular remodeling. (Arq Bras Cardiol. 2014; [online].ahead print, PP.0-0)Conclusions:The functional capacity of isolated CAVB patients with chronic RV pacing was satisfactory but did not correlate with risk factors for ventricular remodeling.
Resumo:
Background: No studies have described and evaluated the association between hemodynamics, physical limitations and quality of life in patients with pulmonary hypertension (PH) without concomitant cardiovascular or respiratory disease. Objective: To describe the hemodynamic profile, quality of life and physical capacity of patients with PH from groups I and IV and to study the association between these outcomes. Methods: Cross-sectional study of patients with PH from clinical groups I and IV and functional classes II and III undergoing the following assessments: hemodynamics, exercise tolerance and quality of life. Results: This study assessed 20 patients with a mean age of 46.8 ± 14.3 years. They had pulmonary capillary wedge pressure of 10.5 ± 3.7 mm Hg, 6-minute walk distance test (6MWDT) of 463 ± 78 m, oxygen consumption at peak exercise of 12.9 ± 4.3 mLO2.kg-1.min-1 and scores of quality of life domains < 60%. There were associations between cardiac index (CI) and ventilatory equivalent for CO2 (r=-0.59, p <0.01), IC and ventilatory equivalent for oxygen (r=-0.49, p<0.05), right atrial pressure (RAP) and 'general health perception' domain (r=-0.61, p<0.01), RAP and 6MWTD (r=-0.49, p<0.05), pulmonary vascular resistance (PVR) and 'physical functioning' domain (r=-0.56, p<0.01), PVR and 6MWTD (r=-0.49, p<0.05) and PVR index and physical capacity (r=-0.51, p<0.01). Conclusion: Patients with PH from groups I and IV and functional classes II and III exhibit a reduction in physical capacity and in the physical and mental components of quality of life. The hemodynamic variables CI, diastolic pulmonary arterial pressure, RAP, PVR and PVR index are associated with exercise tolerance and quality of life domains.
Resumo:
OBJECTIVE Identify resources that support learning mediated by technology in the field of neonatal nursing. METHOD Systematic review with searches conducted in MEDLINE, LILACS and SciELO. Titles and abstracts were independently evaluated by two experts. RESULTS Of the 2,051 references, 203 full-text articles were analyzed, resulting in the inclusion of nine studies on semiotics and semiology, cardiopulmonary resuscitation, general aspects of neonatal care, diagnostic reasoning and assessment of pain. Only two articles addressed the development of educational strategies and seven papers described the assessment of these strategies by experts and/or users. CONCLUSION Distance education is an important resource for education, and its improvement and updating, and it particularly adds advantages for neonatal nursing by approximating teaching and real-life situations and by minimizing the exposure of newborns for teaching purposes. The lack of educational initiatives mediated by technology suggests the need for the development, evaluation and dissemination of educational resources focused on nursing care of newborns and their families.
Resumo:
The objective of this work was to evaluate the genetic diversity of 16 maize inbred lines, and to determine the correlation between genetic distance and hybrid performance, using random amplified polymorphic DNA (RAPD) molecular markers. Twenty-two different random primers were used, which resulted in the amplification of 265 fragments, 237 (84.44%) of them being polymorphic. A genetic similarity matrix was created from the RAPD data, using Jaccard coefficient, and a dendrogram was constructed. Hybrid analyses were carried out using random block design and Griffing method VI for diallel crossings. The genetic associations showed five distinct heterotic groups. Correlations between genetic divergences detected by RAPD, as well as the means observed in the diallel crossings were positive and significant for plant height, ear height, prolificacy, and grain weight. The correlation of genetic divergences, detected by RAPD, and the specific combining ability between heterotic group associations, showed significance in all characteristics under study, except prolificacy. A direct relationship between genetic divergence and productivity was found in 79.2% of the 120 hybrids confirming the hypothesis that genetic divergence is directly related to the performance of hybrids and is efficient in predicting it.
Resumo:
The quantitative structure property relationship (QSPR) for the boiling point (Tb) of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) was investigated. The molecular distance-edge vector (MDEV) index was used as the structural descriptor. The quantitative relationship between the MDEV index and Tb was modeled by using multivariate linear regression (MLR) and artificial neural network (ANN), respectively. Leave-one-out cross validation and external validation were carried out to assess the prediction performance of the models developed. For the MLR method, the prediction root mean square relative error (RMSRE) of leave-one-out cross validation and external validation was 1.77 and 1.23, respectively. For the ANN method, the prediction RMSRE of leave-one-out cross validation and external validation was 1.65 and 1.16, respectively. A quantitative relationship between the MDEV index and Tb of PCDD/Fs was demonstrated. Both MLR and ANN are practicable for modeling this relationship. The MLR model and ANN model developed can be used to predict the Tb of PCDD/Fs. Thus, the Tb of each PCDD/F was predicted by the developed models.
Resumo:
INTRODUCTION: Web-based e-learning is a teaching tool increasingly used in many medical schools and specialist fields, including ophthalmology. AIMS: this pilot study aimed to develop internet-based course-based clinical cases and to evaluate the effectiveness of this method within a graduate medical education group. METHODS: this was an interventional randomized study. First, a website was built using a distance learning platform. Sixteen first-year ophthalmology residents were then divided into two randomized groups: one experimental group, which was submitted to the intervention (use of the e-learning site) and another control group, which was not submitted to the intervention. The students answered a printed clinical case and their scores were compared. RESULTS: there was no statistically significant difference between the groups. CONCLUSION: We were able to successfully develop the e-learning site and the respective clinical cases. Despite the fact that there was no statistically significant difference between the access and the non access group, the study was a pioneer in our department, since a clinical case online program had never previously been developed.
Resumo:
Approximately 7.2% of the Atlantic rainforest remains in Brazil, with only 16% of this forest remaining in the State of Rio de Janeiro, all of it distributed in fragments. This forest fragmentation can produce biotic and abiotic differences between edges and the fragment interior. In this study, we compared the structure and richness of tree communities in three habitats - an anthropogenic edge (AE), a natural edge (NE) and the fragment interior (FI) - of a fragment of Atlantic forest in the State of Rio de Janeiro, Brazil (22°50'S and 42°28'W). One thousand and seventy-six trees with a diameter at breast height > 4.8 cm, belonging to 132 morphospecies and 39 families, were sampled in a total study area of 0.75 ha. NE had the greatest basal area and the trees in this habitat had the greatest diameter:height allometric coefficient, whereas AE had a lower richness and greater variation in the height of the first tree branch. Tree density, diameter, height and the proportion of standing dead trees did not differ among the habitats. There was marked heterogeneity among replicates within each habitat. These results indicate that the forest interior and the fragment edges (natural or anthropogenic) do not differ markedly considering the studied parameters. Other factors, such as the age from the edge, type of matrix and proximity of gaps, may play a more important role in plant community structure than the proximity from edges.
Resumo:
The implementation of local geodetic networks for georeferencing of rural properties has become a requirement after publication of the Georeferencing Technical Standard by INCRA. According to this standard, the maximum distance of baselines to GNSS L1 receivers is of 20 km. Besides the length of the baseline, the geometry and the number of geodetic control stations are other factors to be considered in the implementation of geodetic networks. Thus, this research aimed to examine the influence of baseline lengths higher than the regulated limit of 20 km, the geometry and the number of control stations on quality of local geodetic networks for georeferencing, and also to demonstrate the importance of using specific tests to evaluate the solution of ambiguities and on the quality of the adjustment. The results indicated that the increasing number of control stations has improved the quality of the network, the geometry has not influenced on the quality and the baseline length has influenced on the quality; however, lengths higher than 20 km has not interrupted the implementation, with GPS L1 receiver, of the local geodetic network for the purpose of georeferencing. Also, the use of different statistical tests, both for the evaluation of the resolution of ambiguities and for the adjustment, have enabled greater clearness in analyzing the results, which allow that unsuitable observations may be eliminated.
Resumo:
Two experiments were carried out to evaluate the initial plant growth of Eucalyptus urograndis growing in coexistence with Urochloa decumbens and U. ruziziensis. In 100-L box, one plant of U. decumbens or U. ruziziensis grew in coexistence with one plant of E. urograndis clones C219H or H15, respectively, in the distances of 0, 5, 10, 15, 20, 25, 30, 35, and 40 cm from the crop. After 30, 60, 90 (both clones), and 150 days (just for H15), growth characteristics were evaluated. Plants of both clones, growing in weed-free situations, showed a better growth and development than plants that grew in weedy situations, independently of the distance, having the highest plant height, stem diameter, dry mass of stem, and dry mass of leaves. As the same way, the number of branches, number of leaves, and leaf area of the clone C219H were similarly affected. Urochloa ruziziensis reduced the dry mass accumulation of stem and leaves by the rate of 0.06 and 0.32 g per plant, respectively, per each centimeter growing nearest to the crop, while U. decumbens reduced by 0.03 and 0.14 g per plant. The interference of U. decumbens and U. ruziziensis with E. urograndis is more intense when weedy plants grow in short distances from the crop.
Resumo:
We hypothesized that chronic oral administration of the phosphodiesterase-5 inhibitor sildenafil could improve the exercise capacity and pulmonary hemodynamics in patients with pulmonary arterial hypertension (PAH) on the basis of previous short-term studies. We tested this hypothesis in 14 subjects with PAH, including seven patients with the idiopathic form and seven patients with atrial septal defects, but no other congenital heart abnormalities. Patients were subjected to a 6-min walk test and dyspnea was graded according to the Borg scale. Pulmonary flow and pressures were measured by Doppler echocardiography. Patients were given sildenafil, 75 mg orally three times a day, and followed up for 1 year. Sildenafil therapy resulted in the following changes: increase in the 6-min walk distance from a median value of 387 m (range 0 to 484 m) to 462 m (range 408 to 588 m; P < 0.01), improvement of the Borg dyspnea score from 4.0 (median value) to 3.0 (P < 0.01), and increased pulmonary flow (velocity-time integral) from a median value of 0.12 (range 0.08 to 0.25) to 0.23 (range 0.11 to 0.40; P < 0.01) with no changes in pulmonary pressures. In one patient with pulmonary veno-occlusive disease diagnosed by a lung biopsy, sildenafil had a better effect on the pulmonary wedge pressure than inhaled nitric oxide (15 and 29 mmHg, respectively, acute test). He walked 112 m at baseline and 408 m at one year. One patient died at 11 months of treatment. No other relevant events occurred. Thus, chronic administration of sildenafil improves the physical capacity of PAH patients and may be beneficial in selected cases of veno-occlusive disease.