83 resultados para Disposable Kits
em Scielo Saúde Pública - SP
Resumo:
Serum samples from 150 NS1-negative (Platelia ELISA) patients presumptively diagnosed with dengue were analyzed by the TaqMan probed real-time reverse transcription PCR (TaqMan qRT-PCR) method. The qRT-PCR positive samples were tested for serotype by semi-nested RT-PCR and a qualitative immunochromatographic assay for IgG and IgM. Molecular detection methods showed 33 (22%) positive samples out of 150 NS1-antigen negative samples. Of these, 72% were collected up to day 2 after the onset of symptoms, when diagnostic sensitivity of NS1-antigen test assays is significantly enhanced. Most of the cases were not characterized as secondary infection. Twenty-eight samples were successfully serotyped, 75% of which for DENV-4, 14% for DENV-2, 7% for DENV-3 and 4% for DENV-1. These findings reaffirm the hyperendemic situation of the state of Roraima and suggest a lower sensitivity of the NS1 test, mainly when DENV-4 is the predominant serotype. Health care providers should therefore be aware of samples tested negative by NS1 antigen assays, especially when clinical symptoms and other laboratory data results show evidence of dengue infection.
Resumo:
To evaluate commercial Lionex TB together with four antigens of Mycobacterium tuberculosis (MPT-64, MT10.3, 16 kDa and 38 kDa) for IgG and IgA cerebrospinal fluid (CSF) detection in the diagnosis of tuberculosis meningitis (TBM) with CSF negative acid-fast bacilli staining, 19 cases of TBM, 64 cases of other infectious meningoencephalitis and 73 cases of other neurological disorders were tested by enzyme linked immunosorbent assay. IgA-MPT-64 and IgG Lionex showed the highest sensitivities, specificities, positive predictive value and negative predictive value (63.2%, 47.4%; 95%, 93.7%; 40%, 98% and 28.4%, 97.1%, respectively). However, while grey zone was 12.7% and 6%, respectively, lowering sensitivity but maintains high specificity (> 95%). High protein concentration in CSF was associated with antibody positivity CSF/HIV+ which did not influence the sensitivity of both tests. To our knowledge, this is the first description of IgA-MPT-64 and IgG Lionex antibodies in CSF-TBM and, although there is good specificity, adjustments are needed based on antigen composition to enhance sensitivity.
Resumo:
Kits para aerossol são artigos utilizados na terapêutica de afecções do trato respiratório e requerem no mínimo desinfecção de nível intermediário para reuso. Os objetivos deste estudo foram verificar uma possível contaminação microbiana em kits para aerossol pós-reprocessamento e identificar os microrganismos isolados. Estudo transversal, experimental realizado na unidade pediátrica de um hospital em Goiânia-GO. Coletaram-se amostras de três segmentos (máscara, copo, interior da extensão) de 15 kits previamente desinfetados, que foram semeadas em diferentes meios de culturas e os microrganismos isolados foram identificados por provas bioquímicas. Dos 15 kits analisados, 13 copos, nove extensões e 13 máscaras estavam contaminados. Isolou-se no total 101 UFC, 39 provindos dos copos, 20 das extensões e 42 das máscaras. Dentre os patógenos isolados destaca-se: Staphylococcus coagulase positivo, Staphylococcus coagulase negativo, Bastonetes Gram negativo fermentadores, Bastonetes Gram negativo não fermentadores, micrococose leveduras. A detecção microbiana indica prováveis falhas no reprocessamento desses artigos.
Resumo:
Objective To analyze the direct cost of reusable and disposable aprons in a public teaching hospital. Method Cross-sectional study of quantitative approach, focusing on the direct cost of reusable and disposable aprons at a teaching hospital in northern Paraná. The study population consisted of secondary data collected in reports of the cost of services, laundry, materials and supplies division of the institution for the year 2012 Results We identified a lower average cost of using disposable apron when compared to the reusable apron. The direct cost of reusable apron was R$ 3.06, and the steps of preparation and washing were mainly responsible for the high cost, and disposable apron cost was R$ 0.94. Conclusion The results presented are important for hospital managers properly allocate resources and manage costs in hospitals .
Resumo:
The ocelot (Leopardus pardalis) is included in list of wild felid species protected by CITES and is part of conservation strategies that necessarily involve the use of assisted reproduction techniques, which requires practical and minimally invasive techniques of high reproducibility that permit the study of animal reproductive physiology. The objective of this study was to compare and validate two commercial assays: ImmuChem Double Antibody Corticosterone 125I RIA from ICN Biomedicals, Costa Mesa, CA, USA; and Coat-a-Count Cortisol 125I RIA from DPC, Los Angeles, CA, USA, for assessment of fecal glucocorticoid metabolites in ocelots submitted to ACTH (adrenocorticotropic hormone) challenge. Fecal samples were collected from five ocelots kept at the Brazilian Center of Neotropical Felines, Associação Mata Ciliar, São Paulo, Brazil, and one of the animals was chosen as a negative control. The experiment was conducted over a period of 9 days. On day 0, a total dose of 100 IU ACTH was administered intramuscularly. Immediately after collection the samples were stored at 20C in labeled plastic bags. The hormone metabolites were subsequently extracted and assayed using the two commercial kits. Previously it was performed a trial with the DPC kit to check the best extraction method for hormones metabolites. Data were analyzed with the SAS program for Windows V8 and reported as means ± SEM. The Schwarzenberger extraction method was slightly better when compared with the Wasser extraction method (103,334.56 ± 19,010.37ng/g of wet feces and 59,223.61 ± 12,725.36ng/g of wet feces respectively; P=0,0657). The ICN kit detected an increase in glucocorticoid metabolite concentrations in a more reliable manner. Metabolite concentrations (ng/g wet feces) on day 0 and day 1 were 66,956.28 ± 36,786.93 and 92,991.19 ± 28,555.63 for the DPC kit, and 205,483.32 ± 83,811.32 and 814,578.75 ± 292,150.47 for the ICN kit, respectively. The limit of detection for the ICN kit was 7.7 ng/mL for 100% B/Bo (25ng/mL for 88%B/Bo) and for the DPC kit it was 0.2ug/dL for 90.95% B/Bo (1ug/dL for 81.27% B/Bo). In conclusion it was confirmed that the Schwarzenberger extraction method and the ICN kit are superior for extracting and measuring fecal glucocorticoid metabolites in ocelot fecal samples.
Resumo:
A fasciolose é uma enfermidade causada por um trematoda que acomete o fígado principalmente de ruminantes domésticos, podendo parasitar o homem e seu diagnóstico é realizado rotineiramente por exames coproparasitológicos. O objetivo do presente estudo foi comparar kits comerciais de ELISA para anticorpos no soro e leite com um teste coproprarasitológico em bovinos naturalmente infectados por Fasciola hepatica. Foram coletadas amostras de fezes (92) sangue (92) e leite (43) de bovinos provenientes de propriedades de gado leiteiro do município de Jerônimo Monteiro, sul do Estado do Espírito Santo. As amostras de fezes coletadas foram processadas pela técnica de sedimentação fecal para ovos de F. hepatica, utilizada como padrão ouro para as análises. Amostras de sangue e de leite foram processadas segundo a orientação do fabricante dos respectivos Kits ELISA comerciais testados. Utilizou-se o c² de McNemar para comparação estatística e calcularam-se a sensibilidade e especificidade, valores preditivos e kappa. Os resultados obtidos mostraram que as frequências de positividade pelo uso dos kits ELISA comerciais de soro e de leite diferiram significativamente (p<0,0001) em relação ao exame coproparasitológico. A sensibilidade dos Kits foi de 100%, porém possuíram baixa especificidade, 42,85 e 30% para o soro e leite respectivamente. O coeficiente de kappa mostrou concordância sofrível para os testes de soro (0,33) e de leite (0,21). Os valores preditivos positivos dos kits para soro e leite foram, respectivamente, 44,61 e 38,23% e, os valores preditivos negativos de 100% para ambos os testes. Apesar da maior sensibilidade dos kits ELISA comerciais e, destes apresentarem diferença em relação ao exame coproparasitológico na detecção dos animais positivos para F. hepatica, a escolha de um teste diagnóstico deve considerar o custo benefício. Quando se trata da presença de parasitismo em rebanhos, o tratamento é aplicado em todos os animais e, assim, o exame coproparasitológico para o diagnóstico da doença tem maior eficiência, já que é menos oneroso e de fácil execução.
Resumo:
Foi avaliada a eficiência de dois kits ELISA disponíveis no mercado para detecção de aflatoxina B1, que permitem a triagem de milho contaminado com aflatoxina B1 aos níveis de 5 e 20 ppb. Eles foram comparados ao método de Soares & Rodriguez-Amaya que utiliza cromatografia em camada delgada (CCD) e tem como limite de quantificação 4,0μg/kg (ppb). Foram analisadas 53 amostras incluindo milho, ração para peixe e amendoim e produtos. Os resultados mostraram boa concordância entre as duas técnicas quanto à detecção de aflatoxina B1. O método ELISA mostrou-se mais rápido, menos trabalhoso, utilizando menos solventes orgânicos, porém apresentou resultados presuntivos positivos, tornando necessária a sua confirmação.
Resumo:
The most frequent form of acquisition of Chagas' disease in endemic areas was the transmission through the feces of contaminated triatominae. However, special attention should be paid in urban areas to transmission by blood transfusion, justifying the compulsory screening of blood donors. Early investigations at blood banks in the town of Londrina, Brazil, demonstrated that the seroprevalence of anti-Trypanosoma cruzi antibodies among blood donors was approximately 7.0% in the fifties9,34. Further studies demonstrated pratically the same seroprevalence until the eighties4,32,41. In an attempt to obtain data about the real dimension of the seropositivity for anti-Trypasonoma cruzi antibodies in the region, the authors carried out a large-scale study on 45,774 serum samples from blood donors of the Hemocentro of Hospital Universitário Regional do Norte do Paraná (HURNP), Universidade Estadual de Londrina. The immunological tests were done at the Division of Clinical Immunology of HURNP from May 1990 to December 1994. The serum samples were studied by the indirect hemagglutination assay (IHA, using kits commercially obtained from EBRAM) and by indirect immunofluorescence (IFI, using kits from LIO SERUM) with anti-human IgG conjugate (LABORCLIN). The results demonstrated that 643 serum samples were positive in both assay corresponding to a seroprevalence of 1.4%, i.e., a significant decrease in anti-Trypanosoma cruzi antibodies in the region in comparison with the previously mentioned rates. Data correlating sex and age of seropositive blood donors are presented, as well as the possible factors that may have contributed to the results observed.
Resumo:
There is no paucity of methods for diagnosing Cryptosporidium spp. infection. The merits of immunoassays notwithstanding, microscopic identification of Cryptosporidium spp. oocysts in fecal samples remains an important diagnostic procedure. It owes the persistence of its use to such characteristics as dispensing with expensive equipment and kits, requiring only basic laboratory facilities, and having a low probability of false positive results when permanent slides are prepared, which can be re-examined in case of doubt. Cryptosporidium spp. oocysts can be readily identified in fecal smears prepared according to a regressive iron hematoxylin staining technique. The number of steps and their duration, as well as costs, were reduced to a minimum without loss of image quality and permanence of the preparations.
Resumo:
INTRODUCTION: Information about HIV phenotypes of resistant to available ART and the influence of different risk factors on virological failures (VF) in Costa Rican HIV positive patients prior or during HAART is unknown. MATERIALS AND METHODS: Eighty nine samples, 72 VF and 17 basal (before treatment) were analyzed by examining resistant mutants in reverse transcriptase (RT) and protease (PT) regions using Trugene or LIPA genotyping kits. Sixty eight control patients were selected and relevant information was collected in a questionnaire. RESULTS: Poor adherence, presence of resistant mutations and number of treatment's changes were the only significant factors found (p = 0.006, 0.04 and 0.01 respectively). From 66 sequenced samples, 78%, 50% and 50% showed resistance to NRTI (nucleoside reverse transcriptase inhibitors), NNRT (non-nucleoside reverse transcriptase inhibitors) and PI (protease inhibitors), respectively. The most frequent mutations were M41L, M184V, and T215FY in RT and L62PI, L10FIRV and M36I in PT. DISCUSSION: The most important factor related to treatment response in this study was adherence to treatment. Mutations in RT were related to the treatment failure while the ones found in PT were secondary mutations which have been previously described to influence the selection of primary resistance mutations in these regions. The study reveals the urgency to detect resistant mutations in VF to be considered by physicians for selection of treatment schedule, to analyze basal HIV patients for monitoring of the spread of resistant mutations and the importance to reinforce the adherence in the patients for overall treatment outcome.
Resumo:
Leishmanias can be produced by inoculation in conditioned McCoy cell culture growth medium (CGM). Leishmania (Leishmania) infantum chagasi (100 parasites) grown in NNN medium was inoculated in 2.5 mL CGM, kept in plates (24 wells) and its multiplication was observed for five days (120 hours). After day 5, the medium was saturated with the flagellate forms of the parasite (promastigotes). The reproduction of the leishmanias was observed every 24 hours and the number of parasites was calculated by counting the parasites in a drop of 10 µ L and photomicrographied. So the number of Leishmanias was adjusted to 1 mL volume. The advantage of the technique by isolation of Leishmania in CGM demonstrated in this study is its low cost and high efficacy even with a small quantity of parasites (10² promastigotes) used as inoculum. Additionally, isolation of the leishmania can be obtained together with an increase in their density (180 times) as observed by growth kinetics, within a shorter time. These results justify the use of this low-cost technique for the isolation and investigation of the behavior and multiplication of Leishmania both in vertebrates and invertebrates, besides offering means of obtaining antigens, whether whole antigens (leishmanias) or the soluble antigens produced by the parasites which may be useful for the production of new diagnostic kits.
Resumo:
The current diagnosis of human T-lymphotropic virus type-2 (HTLV-2) infection is based on the search of specific antibodies; nevertheless, several studies conducted in Brazil pointed deficiencies of the commercially available kits in detecting HTLV-2, mostly in HIV/AIDS patients. This study searched for the presence of HTLV-1 and -2 in 758 HIV/AIDS patients from Londrina, Paraná, Brazil. Serum samples were screened for HTLV-1/2 antibodies using two EIA kits (Vironostika and Murex), and confirmed by WB (HTLV Blot 2.4, Genelabs). The results obtained by EIA disclosed 49 (6.5%) reactive sera: 43 positive by both EIA kits, and six with discordant results. WB confirmed HTLV-1 infection in seven samples (0.9%) and HTLV-2 in 21 sera (2.8%). Negative and indeterminate results were detected in four (0.5%) and 16 (2.1%) sera, respectively. Blood from 47 out of 49 HTLV seroreactive patients were collected and analyzed for the presence of env, LTR and tax genomic segments of HTLVs by PCR. PCR confirmed six cases of HTLV-1 and 37 cases of HTLV-2 infection (14 out of 16 that were found to be WB indeterminate). Restriction analysis of the env PCR products of HTLV-2 disclosed 36 isolates of HTLV-2a/c subtype, and one of HTLV-2b subtype. These results emphasize the need of improving serologic tests for detecting truly HTLV-2 infected patients from Brazil, and confirm the presence of HTLV-2b subtype in the South of this country.
Resumo:
Testing problems in diagnosing human T-lymphotropic virus (HTLV) infection, mostly HTLV-II, have been documented in HIV/AIDS patients. Since December 1998, the Immunology Department of Instituto Adolfo Lutz (IAL) offers HTLV-I/II serology to Public Health Units that attend HTLV high-risk individuals. Two thousand, three hundred and twelve serum samples: 1,393 from AIDS Reference Centers (Group I), and 919 from HTLV out-patient clinics (Group II) were sent to IAL for HTLV-I/II antibodies detection. The majority of them were screened by two enzyme immunoassays (EIAs), and confirmed by Western Blot (WB 2.4, Genelabs). Seven different EIA kits were employed during the period, and according to WB results, the best performance was obtained by EIAs that contain HTLV-I and HTLV-II viral lysates and rgp21 as antigens. Neither 1st and 2nd, nor 3rd generation EIA kits were 100% sensitive in detecting truly HTLV-I/II reactive samples. HTLV-I and HTLV-II prevalence rates of 3.3% and 2.5% were detected in Group I, and of 9.6% and 3.6% in Group II, respectively. High percentages of HTLV-seroindeterminate WB sera were detected in both Groups. The algorithm testing to be employed in HTLV high-risk population from São Paulo, Brazil, needs the use of two EIA kits of different formats and compounds as screening, and because of high seroindeterminate WB, may be another confirmatory assay.
Resumo:
Molecular characterization of Cryptosporidium spp.oocysts in clinical samples is useful for public health since it allows the study of sources of contamination as well as the transmission in different geographical regions. Although widely used in developed countries, in Brazil it is restricted to academic studies, mostly using commercial kits for the extraction of genomic DNA, or in collaboration with external reference centers, rendering the method expensive and limited. The study proposes the application of the modifications recently introduced in the method improving feasibility with lower cost. This method was efficient for clinical samples preserved at -20 °C for up to six years and the low number of oocysts may be overcomed by repetitions of extraction.
Resumo:
Over a two year period, the incidence of hepatitis C virus (HCV) infection was evaluated in 29 hemodialysis patients, aged between 15 and 75 years (mean ± SD: 45 ± 39.5 years), from the University Hospital Hemodyalisis Unit, Maracaibo, Zulia State, Venezuela. Anti-HCV antibodies were determined using a fourth generation ELISA (Innotest HCV Ab IV) kit and positive blood samples were tested using a recombinant assay kit (Inno-LIA HCV Ab III), both kits from Innogenetics N.V., Belgium. The findings indicate a lack of HCV seroconversion in the hemodialysis patients over the study period, confirmed by the recombinant assay. Risk factors for HCV infection were 0.3270 (95% confidence interval: 0.01323-8.080) in patients undergoing hemodialysis. The findings suggest a lack of significant sources for HCV infection due to the preventive measures to avoid its transmission in the hemodialysis unit.