42 resultados para Diode lasers

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides an up-to-date critical review of methods for diamond synthesis by lasers. A provisional classification of synthesizing methods is carried out, in order to present a varied and heterogeneous experimental work that is as clear as possible. Laser diamond CVD methods involve chemical processes in a carbon-containing system induced by specific absorption of laser radiation, while diamond PVD methods involve physical processes induced by an intense, highly-directed laser beam. Different methods involving coupled, simultaneous action of lasers and classic CVD agents are suggested and discussed as prospective approaches for diamond synthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Potential energy and dipole moment curves for the HCl molecule were computed. Calculations were performed at different levels of theory (DFT, MRCI). Spectroscopic properties are reported and compared with experimental data, for validating the theoretical approaches. Interaction of infrared radiation with HCl is simulated using the wave packet formalism. The quantum control model for population dynamics of the vibrational levels, based on pi-pulse theory, is applied. The results demonstrate that wavepackets with specific composition can be built with short infrared laser pulses and provide the basis for studies of H + HCl collision dynamics with infrared laser excitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light emitting diode (LED) has been used in commercial poultry industry by presenting superior energy savings and providing feasibility on production process. The objective of this research was to evaluate performance and carcass yield of broiler chickens exposed to different LED colors compared with fluorescent lamps. For that, two experiments (E1 and E2) were performed and 2,646 Cobb® chickens were used. In experiment E1, male birds were exposed to 20 lux artificial lighting with red, yellow, blue, and white LED bulbs; and fluorescent bulb. In experiment E2, male and female birds were exposed to 15 lux artificial lighting with red and blue LED bulbs; and fluorescent bulb. Cumulative weight gain (kg), feed intake (kg), feed conversion, hot carcass weight (kg), carcass yield (%), and breast and thigh + drumstick yield (%) were used as response variables. Results showed no difference (p > 0.05) among treatments for performance, carcass yield, and cut yield in experiment E1. In experiment E2 there was only difference between genders (p < 0.05) and males showed higher total weight gain, feed intake, hot carcass weight and thigh + drumstick yield. Different LED color use had same effect as fluorescent lights on broiler performance and carcass yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-intensity lasers are used for prevention and management of oral mucositis induced by anticancer therapy, but the effectiveness of treatment depends on the genetic characteristics of affected cells. This study evaluated the survival and induction of filamentation of Escherichia coli cells deficient in the nucleotide excision repair pathway, and the action of T4endonuclease V on plasmid DNA exposed to low-intensity red and near-infrared laser light. Cultures of wild-type (strain AB1157) E. coli and strain AB1886 (deficient in uvrA protein) were exposed to red (660 nm) and infrared (808 nm) lasers at various fluences, powers and emission modes to study bacterial survival and filamentation. Also, plasmid DNA was exposed to laser light to study DNA lesions produced in vitro by T4endonuclease V. Low-intensity lasers:i) had no effect on survival of wild-type E. coli but decreased the survival of uvrA protein-deficient cells,ii) induced bacterial filamentation, iii) did not alter the electrophoretic profile of plasmids in agarose gels, andiv) did not alter the electrophoretic profile of plasmids incubated with T4 endonuclease V. These results increase our understanding of the effects of laser light on cells with various genetic characteristics, such as xeroderma pigmentosum cells deficient in nucleotide excision pathway activity in patients with mucositis treated by low-intensity lasers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a voz de pacientes portadores de carcinomas iniciais glóticos submetidos à cordectomia com laser de CO2. MÉTODO: Foram avaliados 15 pacientes com diagnóstico de carcinoma espinocelular Tis e T1 glóticos. A avaliação foi feita por meio da análise perceptivo auditiva da voz, pela análise acústica computadorizada e videolaringoestroboscópica. Os pacientes responderam a um questionário de avaliação geral da voz e um protocolo de qualidade de vida relacionado à voz (QVV). Os resultados foram comparados aos de um grupo controle de indivíduos com laringes normais. RESULTADOS: A análise perceptivo-auditiva da voz revelou que a maioria dos pacientes submetidos à cordectomia apresentou algum grau de disfonia, à custa de rouquidão e soprosidade. Considerando os parâmetros acústicos analisados e os valores do grupo controle, observou-se a tendência de um pequeno incremento da freqüência fundamental, mas sem diferença estatisticamente significante; os valores de jitter, shimmer e da proporção harmônico-ruído apresentaram-se significantemente alterados. Os aspectos analisados na videolaringoestroboscopia mostraram-se melhores nas cordectomias menos extensas. Os escores do QVV sugerem que os pacientes tiveram um discreto impacto na qualidade de vida relacionada à voz. CONCLUSÕES: Apesar da presença de alterações na qualidade vocal dos pacientes submetidos à cordectomia com laser de CO2, os resultados funcionais tendem a ser bem aceitos pelos pacientes, com discreta repercussão na qualidade de vida.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Otite média secretora (OMS) e otite média aguda recorrente (OMAR) podem necessitar tratamento cirúrgico para adequada ventilação da orelha média. A abertura clássica do tímpano (timpanocentese) requer incisão por microlanceta sob controle de microscópio cirúrgico e mantém-se patente por alguns dias. Estudos recentes sugerem que a timpanocentese feita por diferentes lasers pode permanecer permeável por maior tempo, o que possibilitaria a normalização da otite média. MATERIAL E MÉTODOS: Neste estudo experimental 34 ratos linhagem Wistar, albinos, machos adultos pesando cerca de 300g, foram anestesiados com cetamina 27 mg/kg e xilazina 2,7 mg/kg. A seguir, foram submetidos à timpanocentese incisional com microlanceta no ouvido direito (ML-OD), e à timpanocentese mediada por laser de argônio no ouvido esquerdo (LA-OE). RESULTADOS: Não houve diferença significativa no tempo de cicatrização das timpanocenteses feitas com laser de argônio ou microlanceta. Todas as timpanocenteses cicatrizaram em 10 dias. CONCLUSÃO: A timpanocentese com laser de argônio apresentou patência e cicatrização semelhantes à técnica clássica com microlanceta realizada em ratos Wistar sem enfermidades de orelha média.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A carga mecânica provoca microdeformações ósseas, que estimulam células osteoblásticas e, conseqüentemente, promovem adaptações nos ossos, muitas vezes relacionadas com uma menor reabsorção óssea e um aumento na formação óssea local. No entanto, o estímulo para formação óssea depende do número e freqüência das deformações aplicadas no osso. Concomitantemente aos estímulos ósseos providos pelas cargas mecânicas, é importante uma dieta rica em cálcio, a qual também beneficia o aumento da massa óssea. Entretanto, existem também outros métodos não farmacológicos, como o ultra-som pulsado de baixa intensidade, a estimulação elétrica e o laser, que já mostraram efeitos positivos na promoção da osteogênese. Assim, realizou-se um levantamento na literatura, no período de 1982 a 2001, sobre esses métodos não farmacológicos com o objetivo de avaliar tais métodos alternativos, que ajudam no aumento da massa óssea ou no estímulo à osteogênese.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The polar hydroethanolic extract from Selaginella sellowii(SSPHE) has been previously proven active on intracellular amastigotes (in vitro test) and now was tested on hamsters infected with Leishmania (Leishmania) amazonensis (in vivo test). SSPHE suppressed a 100% of the parasite load in the infection site and draining lymph nodes at an intralesional dose of 50 mg/kg/day × 5, which was similar to the results observed in hamsters treated with N-methylglucamine antimonate (Sb) (28 mg/Kg/day × 5). When orally administered, SSPHE (50 mg/kg/day × 20) suppressed 99.2% of the parasite load in infected footpads, while Sb suppressed 98.5%. SSPHE also enhanced the release of nitric oxide through the intralesional route in comparison to Sb. The chemical fingerprint of SSPHE by high-performance liquid chromatography with diode-array detection and tandem mass spectrometry showed the presence of biflavonoids and high molecular weight phenylpropanoid glycosides. These compounds may have a synergistic action in vivo. Histopathological study revealed that the intralesional treatment with SSPHE induced an intense inflammatory infiltrate, composed mainly of mononuclear cells. The present findings reinforce the potential of this natural product as a source of future drug candidates for American cutaneous leishmaniasis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a reprodutibilidade do posicionamento de pacientes com diagnóstico de câncer de próstata submetidos a radioterapia conformada. MATERIAIS E MÉTODOS: Foram avaliados 960 (posições anterior e lateral) filmes radiológicos, de um total de 120 pacientes que receberam radioterapia conformada na próstata com técnica isocêntrica. As imagens foram obtidas em acelerador linear de partículas 6 MV. Aplicou-se protocolo específico para planejamento e tratamento da próstata, com o paciente em posição supina, mãos colocadas sobre o tórax, pés apoiados em suporte apropriado. Diariamente, os pacientes foram posicionados conforme demarcações na pele, coincidentes com os lasers da sala. Os filmes radiológicos foram comparados com as radiografias reconstruídas digitalmente (digitally reconstructed radiography - DRR) em sistema de planejamento computadorizado Eclipse, a partir das tomografias. As radiografias de posicionamento foram realizadas no primeiro dia e após, semanalmente, até o término do tratamento. RESULTADOS: As médias dos deslocamentos observados foram de 1,99 ± 1,25 mm no sentido crânio-caudal, 1,37 ± 0,84 mm no látero-lateral e 1,94 ± 1,10 mm no ântero-posterior. CONCLUSÃO: O uso de protocolos específicos para posicionamento dos pacientes é possível na prática clínica, possibilita reprodutibilidade adequada e rápida correção dos possíveis erros.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Objective: To determine whether low-level laser therapy can prevent salivary hypofunction after radiotherapy and chemotherapy in head and neck cancer patients. Materials and Methods: We evaluated 23 head and neck cancer patients, of whom 13 received laser therapy and 10 received clinical care only. An InGaAlP laser was used intra-orally (at 660 nm and 40 mW) at a mean dose of 10.0 J/cm2 and extra-orally (at 780 nm and 15 mW) at a mean dose of 3.7 J/cm2, three times per week, on alternate days. Stimulated and unstimulated sialometry tests were performed before the first radiotherapy and chemotherapy sessions (N0) and at 30 days after the end of treatment (N30). Results: At N30, the mean salivary flow rates were significantly higher among the laser therapy patients than among the patients who received clinical care only, in the stimulated and unstimulated sialometry tests (p = 0.0131 and p = 0.0143, respectively). Conclusion: Low-level laser therapy, administered concomitantly with radiotherapy and chemotherapy, appears to mitigate treatment-induced salivary hypofunction in patients with head and neck cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction and evaluation of an inexpensive flow photometer for clinical analysis, using a bicolour LED and a phototransistor adapted for tubular flow cell, are described. The instrument presents some new features such as: automatic zero, electronic calibration and peak-hold signal. When compared with a classical photometer, it is simpler and has the advantages of a flow analysis system: lower volumes of reagents and samples, lower levels of contamination, shorter time for analysis and lower analysis costs. The instrument was used in the determination of the constituents in blood samples. The results obtained agree with those obtained by a classical photometer and the precision was better.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multicomponent ( Al2O3, CaO, SiO2, MgO) calcium aluminate-based glasses containing Nd3+ were prepared in order to evaluate their possibilities as laser host materials. The refractive index, UV-visible-near IR absorption spectrum, IR and visible luminescence spectra, and fluorescence decay time were measured. Judd-Ofelt model was used to obtain experimental intensity parameters ( omega2, omega4 and omega6), emission cross-section, radiative lifetimes, emission branching ratios and quantum efficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensitive and simple system was proposed for the in situ measurement of total aldehyde in outdoor or indoor ambient. The method is based on the use of a reagent drop as an useful interface to preconcentrate the sample prior to determination of total aldehyde as formaldehyde. The drop is formed at the tip of a cylindrical tube that contains two optical fibers placed on opposite sides and in contact with the reagent solution. One optical fiber carries the red light to the drop form a light emitting diode (LED). The transmitted light is measured by a second optical fiber/photodiode system. The analytical signal is read and converted into absorbance. The reagent solution of 3-methyl-2-benzothiazoline hydrazone (MBTH) forms a blue cation during reaction with formaldehyde that can be measured at 660 nm. Some aspects of kinetics reaction formation of dye were reevaluated. The formaldehyde reacts with MBTH and forms the azine in about 12 min. The oxidation of MBTH by Fe (III) and the formation of dye requires 3 min. The absorbance of the reagent drop is proportional to the sampling time and to the analyte concentration. The absorbance signal increases with increased sample gas flow until a maximum is reached then decreases until it forms a plateau. The proposed method was evaluated using both outdoor and indoor samples, and it was shown to viable provide an accurate measure of total aldehyde.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this review it is presented some aspects of electrothermal atomic absorption spectrometry with tungsten coil (ETAW-AAS) since its beginning until the present days as well as the perspectives for this technique. Some aspects concerning its development and theoretical concepts are discussed. The analytical figures of merit such as limit of detection (LD), characteristic mass (m0), relative standard deviation (RSD), accuracy and precision are evaluated, compared and discussed considering published works. It is also evaluated its advantages, applications, limitations and instrumental development. The use of diode laser as radiation source and its perspectives to ETAW are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The quantitative chemical analysis of the Brazilian sugar cane spirit distilled from glass column packaged with copper, stainless steel, aluminum sponge, or porcelain balls is described. The main chemical compounds determined by gas chromatography coupled with flame ionization (FID) and flame photometric (FPD) detectors and liquid chromatography coupled with diode array detector are aldehydes, ketones, carboxylic acids, alcohols, esters and dimethylsulfite (DMS). The spirits produced either in columns filled with copper or aluminum pot still exhibits the lowest DMS contents but the higher sulfate and methanol contents, whereas spirits produced in stainless steel or porcelain showed higher DMS concentration and lower teors of sulfate ion and methanol. These observations are coherent with DMS oxidation to sulfate, with methanol as by product, in the presence of either copper or aluminum.