6 resultados para Dammann grating

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Total urinary neutral 17-steroids were determined in normal and in castrated horses. One liter of a 15-26 hours urine collection was hydrolysed by refluxing with 10% HC1 (v/v) for ten minutes and extracted with peroxyde-free ethyl ether. The extract was purified by washing with saturated NaHCO³ and KOH solutions. One half of the crude neutral fraction was fractionated with Girard's "T" reagent . The Zimmermann reaction was performed both in the ketonic and in the crude neutral extracts, using alcoholic 2.5N KOH and a 60 minutes period for the colour development in the dark. Optical density measuments were made in a grating Coleman Universal Spectrophotometer at 420 mµ and 520mµ; for the crude neutral fraction a colour correction equation was applied. The aliquot fraction used for colorimety was adjusted for keeping optical density measurements within the range 0.2 to 0.7. Androsterone (mp. 184-184.5°C) with an absorption maximum at 290.5 mµ (Beckman Model DU Spectrophotometer) was used as a reference standard. Table I, ilustrates the results obtained. At the 0.05 probability level there is a significant difference among castrated and normal group means (Fischer's "t" test.) when were used the data obtained from the ketonic fractions; in spite of the use of a colour correction applied for inespecific chromogens, the same results could not be obtained with the crude neutral fractions, Since Girard's reagent fractionation is generaly accepted as the best method for correcting the inespecific chromogen interference in the determination of the 17-ketosteroids by the Zimmermann reaction, we emphasize the value of the results obtained with the ketonic fractions. From these results it appears, as occurs in others mammals, that castrated horses show a lower level of urinary 17-ketosteroids excretion than the normal horses. The significance of the horse testis contribution for the neutral urinary steroid metabolites is discussed. Since horse urine has a low androgenic activity, the fractionation of the neutral 17-ketosteroids must be studied more accurately.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A threshold photoelectron spectrometer applied to the study of atomic and molecular threshold photoionization processes is described. The spectrometer has been used in conjunction with a toroidal grating monochromator at the National Synchrotron Radiation Laboratory (LNLS), Brazil. It can be tuned to accept threshold electrons (< 20 meV) and work with a power resolution of 716 (~18 meV at 12 eV) with a high signal/noise ratio. The performance of this apparatus and some characteristics of the TGM (Toroidal Grating Monochromator) beam line of LNLS are described and discussed by means of argon, O2 and N2 threshold photoelectron spectra.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The potentialities of X-ray Absorption Near Edge Spectroscopy (XANES) of the N K edge (N K) obtained with the spherical grating monochromator beam line at the Brazilian National Synchrotron Light Laboratory are explored in the investigation of poly(aniline), nanocomposites and dyes. Through the analysis of N K XANES spectra of conducting polymers and many other dye compounds that are dominated by 1s®p* transitions, it was possible to correlate the band energy value with the nitrogen oxidation states. An extensive N K XANES spectral database was obtained, thus permitting the elucidation of the nature of different nitrogens present in the intercalated conducting polymers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to measure contrast sensitivity curves for angular frequencies in the range between 2 and 96 cycles/360º in older human adult volunteers and to compare these measurements with the more usual contrast sensitivity functions for sine-wave gratings. All subjects were free of identifiable ocular disease and had normal acuity. We measured the contrast thresholds for young adults (N = 6; age range, 20-26 years) and older adults (N = 6; age range, 60-67 years) using the psychophysical forced-choice method. In this paradigm the volunteers had to choose the stimulus containing a test frequency at low contrast (e.g., either a sine-wave grating or an angular frequency stimulus), or another neutral stimulus at mean luminance (without any contrast). Older adults presented a loss in contrast sensitivity at high and medium angular frequencies compared to the young adults (i.e., from 8 to 96 cycles/360º). Contrary to expectation, contrast sensitivity at low angular frequencies, i.e., 2 and 4 cycles/360º, was better for the older group than for the younger group. On the other hand, contrast sensitivity for sine-wave gratings at 3 and 4 cpd was higher for young adults as expected. These results suggest age-related changes in the contrast sensitivity function for angular frequencies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An assumption commonly made in the study of visual perception is that the lower the contrast threshold for a given stimulus, the more sensitive and selective will be the mechanism that processes it. On the basis of this consideration, we investigated contrast thresholds for two classes of stimuli: sine-wave gratings and radial frequency stimuli (i.e., j0 targets or stimuli modulated by spherical Bessel functions). Employing a suprathreshold summation method, we measured the selectivity of spatial and radial frequency filters using either sine-wave gratings or j0 target contrast profiles at either 1 or 4 cycles per degree of visual angle (cpd), as the test frequencies. Thus, in a forced-choice trial, observers chose between a background spatial (or radial) frequency alone and the given background stimulus plus the test frequency (1 or 4 cpd sine-wave grating or radial frequency). Contrary to our expectations, the results showed elevated thresholds (i.e., inhibition) for sine-wave gratings and decreased thresholds (i.e., summation) for radial frequencies when background and test frequencies were identical. This was true for both 1- and 4-cpd test frequencies. This finding suggests that sine-wave gratings and radial frequency stimuli are processed by different quasi-linear systems, one working at low luminance and contrast level (sine-wave gratings) and the other at high luminance and contrast levels (radial frequency stimuli). We think that this interpretation is consistent with distinct foveal only and foveal-parafoveal mechanisms involving striate and/or other higher visual areas (i.e., V2 and V4).