100 resultados para DIGITAL SUBTRACTION
em Scielo Saúde Pública - SP
Resumo:
Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.
Resumo:
Carbon dioxide gas (CO2) is generally considered a safe alternative contrast media for digital subtraction angiography in patients with renal insufficiency ar hypersensitivity to iodinated contrast material. In this article we report one case in wich this technique was used successfully in a 48 years old man with elevated levels of creatinine and blood urea nitrogen suffering from a trofic isquemic lesion in lhe right toe. The method was used preoperatively after an inconclusive duplex scan of lhe limb. No complications related to the method of imaging were found and the patient submitted to a bypass grafting revascularization procedure.
Resumo:
The objective of the present study was to determine the frequency of the most common clinical features in patients with autosomal dominant polycystic kidney disease in a sample of the Brazilian population. The medical records of 92 patients with autosomal dominant polycystic kidney disease attended during the period from 1985 to 2003 were reviewed. The following data were recorded: age at diagnosis, gender, associated clinical manifestations, occurrence of stroke, age at loss of renal function (beginning of dialysis), and presence of a family history. The involvement of abdominal viscera was investigated by ultrasonography. Intracranial alterations were prospectively investigated by magnetic resonance angiography in 42 asymptomatic patients, and complemented with digital subtraction arteriography when indicated. Mean age at diagnosis was 35.1 ± 14.9 years, and mean serum creatinine at referral was 2.4 ± 2.8 mg/dL. The most frequent clinical manifestations during the disease were arterial hypertension (63.3%), lumbar pain (55.4%), an abdominal mass (47.8%), and urinary infection (35.8%). Loss of renal function occurred in 27 patients (mean age: 45.4 ± 9.5 years). The liver was the second organ most frequently affected (39.1%). Stroke occurred in 7.6% of the patients. Asymptomatic intracranial aneurysm was detected in 3 patients and arachnoid cysts in 3 other patients. In conclusion, the most common clinical features were lumbar pain, arterial hypertension, abdominal mass, and urinary infection, and the most serious complications were chronic renal failure and stroke. Both intracranial aneurysms and arachnoid cysts occurred in asymptomatic patients at a frequency of 7.14%.
Resumo:
OBJETIVO: objetivo desta pesquisa foi investigar o grau de satisfação entre os usuários de Aparelho de Amplificação Sonora (AAS) de tecnologia analógica e digital. FORMA DE ESTUDO: clínico com coorte transversal. MATERIAL E MÉTODO: A amostra foi constituída de 40 usuários de AAS unilateral, sendo 20 de tecnologia analógica (Grupo I) e 20 de tecnologia digital (Grupo II). Os indivíduos são portadores de perda auditiva neurossensorial, de configuração plana, de grau leve a moderado, com idade entre 40 e 95 anos. O instrumento de avaliação utilizado foi o International Outcome Inventory for Hearing Aids (IOI-HA - Versão em Português) proposto por Cox et al. (2002). RESULTADOS: Os resultados mostraram que os usuários do Grupo II utilizam o AAS por mais tempo diariamente e também apresentam um grau de dificuldade menor em determinadas situações com o uso da amplificação, comparado aos usuários do Grupo I. Os usuários do Grupo II relatam que sua perda auditiva não afeta em nada sua relação com terceiros. CONCLUSÃO: Apesar de os resultados revelarem que os usuários do Grupo I apresentam um handicap auditivo mais acentuado comparado aos usuários do Grupo II, o grau de satisfação com relação à amplificação não apresenta diferença significativa entre os dois grupos.
Resumo:
Este artigo investiga as representações sociais que emergem da participação pública mediada pelo uso de Tecnologias de Informação e Comunicação (TIC). A prefeitura de Belo Horizonte, em 2006, usou pela primeira vez a TIC no Orçamento Participativo Digital (OP Digital). Foi uma escolha da população das obras prioritárias para o biênio seguinte. O OP Digital foi repetido em 2008 e 2011, mas com participação inferior à obtida na primeira edição. Realizamos este trabalho para compreender o uso da internet pelo cidadão na tomada de decisão pública e para explicar a diminuição da sua participação. Os procedimentos metodológicos estão ancorados na teoria das representações sociais e na análise crítica do discurso de 101 textos - da imprensa e de órgãos públicos ou representantes do governo. Os resultados nos indicam que não está sendo explorado o potencial de interação e construção coletiva da internet, ancorando a nova prática em uma votação, dessa forma, trivializando-a. Essa pode ser uma das razões para o abandono da participação.
Resumo:
Este trabalho analisa três edições (2006, 2008 e 2011) do Orçamento Participativo Digital (OPD) de Belo Horizonte (MG). Objetiva deslindar os sentidos e significados da participação democrática mediada pela internet nessa experiência. Utiliza-se como método o estudo de caso único, de natureza qualitativa. Os dados foram coletados por meio de observação direta nos sítios do OPD e análise documental. Durante a fase de observação direta foram coletadas mensagens e manifestações dos cidadãos que estavam participando do processo. Tais dados foram tratados com o software Atlas TI 6.0®. Conclui-se que tanto o sentido quanto o significado democrático dessa experiência de participação mediadas pela internet são modificados ao longo das edições, indo de grandes impulsos de esperança democrática até a descrença nessa modalidade de participação digital.
Resumo:
ABSTRACT This study aimed to describe the digital disease detection and participatory surveillance in different countries. The systems or platforms consolidated in the scientific field were analyzed by describing the strategy, type of data source, main objectives, and manner of interaction with users. Eleven systems or platforms, developed from 1996 to 2016, were analyzed. There was a higher frequency of data mining on the web and active crowdsourcing as well as a trend in the use of mobile applications. It is important to provoke debate in the academia and health services for the evolution of methods and insights into participatory surveillance in the digital age.
Resumo:
OBJETVO: Detectar a freqüência da prescrição do digital, assim como as suas indicações, em idosos admitidos em unidade de geriatria de um hospital geral. MÉTODOS: Foram investigados, consecutivamente, 130 pacientes não selecionados, de ambos os sexos (100 mulheres e 30 homens), com idades > ou = 65 (média 80±9) anos. Os pacientes foram avaliados através de exame clínico completo, rotina básica de sangue, radiografia simples de tórax, eletrocardiograma e ecocardiograma Doppler. Baseados na avaliação clínica e exames complementares, o uso do digital foi considerado adequado, questionável ou inadequado. RESULTADOS: Estavam em uso de digital 27,6% dos pacientes. A indicação foi considerada adequada em 36,1%, questionável em 11,1% e inadequada em 52,7%. CONCLUSÃO: Uma alta prevalência de prescrição do digital foi detectada nos idosos admitidos, sendo que a maior parte a adotava por razões consideradas inadequadas ou questionáveis. Devido ao risco aumentado de intoxicação digitálica nessa faixa etária, a droga deveria ser prescrita sob indicações mais criteriosas.
Resumo:
FUNDAMENTO: Medidas válidas da pressão arterial, em situações clínicas e na comunidade, são essenciais para a monitoração dessa variável em nível populacional. OBJETIVO: Avaliar a validade de um monitor digital de pulso para mensuração da pressão arterial em adolescentes, em comparação com um esfigmomanômetro de mercúrio. MÉTODOS: Um estudo de validação foi realizado na cidade de Pelotas, região sul do Brasil. A pressão arterial foi medida duas vezes, utilizando-se dois esfigmomanômetros diferentes: um aparelho digital de pulso OMRON e um aparelho de mesa BD de mercúrio. Metade da amostra foi medida primeiro através do manômetro digital e depois pelo de mercúrio, enquanto a outra metade foi avaliada na ordem inversa. A concordância entre as duas medidas foi avaliada através do método de Bland & Altman. RESULTADOS: 120 adolescentes com idade entre 14 e 15 anos foram incluídos no estudo (50% de cada sexo). A pressão sistólica média entre os meninos foi de 113,7 mmHg (DP 14,2) usando o manômetro de mercúrio e 115,5 mmHg (DP 15,2) usando o aparelho digital. Os valores equivalentes para a pressão diastólica foram 61,5 mmHg (DP 9,9) e 69,6 mmHg (10,2), respectivamente. Entre as meninas, a pressão sistólica média foi de 104,7 mmHg (DP 10,1) usando o manômetro de mercúrio e 102,4 mmHg (DP 11.9) usando o aparelho digital. Os valores equivalentes para a pressão diastólica foram 60,0 mmHg (DP 10,4) e 65,7 mmHg (DP 7,7), respectivamente. CONCLUSÕES: O manômetro digital apresentou alta concordância com o manômetro de mercúrio para medir a pressão arterial sistólica. A concordância foi menor para a pressão arterial diastólica. O uso de equações de correção pode ser uma alternativa para estudos utilizando esse monitor digital de pulso em adolescentes.
Resumo:
O exame físico cardiovascular, em particular a ausculta cardíaca, é uma das habilidades clínicas mais difíceis para os alunos durante seu treinamento médico. Estudos sugerem que o uso de tecnologias, como o estetoscópio digital, aumente a acurácia do exame clínico, entretanto, seu impacto no ensino da propedêutica da ausculta cardíaca em alunos de graduação de Medicina não é conhecido. O objetivo é demonstrar a utilidade do estetoscópio digital, em comparação com métodos tradicionais, como instrumento de ensino da ausculta cardíaca. Estudo de intervenção, longitudinal, controlado, unicêntrico e randomizado. Foram inscritos 38 alunos de medicina para um curso de semiologia cardiovascular com duração de oito semanas. Definiu-se um programa com aulas expositivas e à beira do leito nas enfermarias de Cardiologia. Nas aulas práticas, os alunos foram randomizados em dois grupos: 1) (n = 21) estetoscópio digital (Littmann® modelo 3200, 3M); e 2) (n = 17) estetoscópios convencionais. Foi realizada uma avaliação pré-treinamento, através de um teste utilizando o software Heart Sounds®, que foi repetida ao final do curso. As médias das avaliações foram comparadas pelo teste T pareado e não pareado. Observa-se que, ao final do curso, houve uma melhora significativamente maior no grupo que utilizou o estetoscópio digital (51,9%) quando comparado ao grupo que utilizou o estetoscópio convencional (29,5%). Intervenções de curta duração para o ensino de semiologia cardíaca são capazes de contribuir de modo significativo para melhora da proficiência da identificação dos sons cardíacos. O uso do estetoscópio digital demonstrou ser um fator positivo no ensino dessas habilidades.
Resumo:
O objetivo do estudo foi caracterizar o perfil de licenciandos de enfermagem, identificar a fluência digital, o conhecimento, a habilidade e o interesse no uso de ambientes virtuais de aprendizagem. Trata-se de uma pesquisa quantitativa, exploratório-descritiva realizada com 51 licenciandos de enfermagem por meio de questionário. Dos participantes do estudo 51 (100%) afirmam ter conhecimento em informática, sendo que 26 (49%) indicam um nível intermediário; 47 (92%) fazem uso diário da Internet; 51 (100%) navegam em redes sociais e possuem e-mail; 51(100%) utilizam MSN e 32 (62,7%) Skype; 41 (82%) acessam Chats, 33 (64,7%) Fóruns de discussão e 22 (43%) Blogs; 33 (64,7%) utilizam frequentemente o Moodle e 26 (51%) o COL; e a grande maioria (45- 88,2%) relatou interesse no uso de ambientes virtuais de aprendizagem. Os alunos foram considerados fluentes digitais e apresentaram conhecimento, habilidade e expressivo interesse no uso de ambientes virtuais de aprendizagem em sua formação acadêmica.
Resumo:
Estudo descritivo, exploratório, realizado na cidade de São Paulo, que objetivou identificar o perfil, as competências e a fluência digital do enfermeiro aprimorando para uso da tecnologia no trabalho. A população composta por 60 aprimorandos do Programa de Aprimoramento Profissional respondeu um questionário com dados sobre o perfil, a fluência digital e as competências profissionais. Verificou-se que 95,0% dos participantes eram do sexo feminino, 61,7% na faixa etária entre 23 a 25 anos, 75,0% graduados em escolas públicas, 58,3% cursando enfermagem cardiovascular, 98,3% teve contato com recursos computacionais na graduação; 100,0% possuía computador em casa; 86,7% acessava a internet diariamente; 96,7% utilizava o Messenger e 58,3% apresentava grau intermediário de conhecimento e habilidade em informática. As competências profissionais requeridas frente à tecnologia referiram-se ao saber ser inovador, criativo, atualizado para conhecer e gerenciar programas e saber utilizar os recursos tecnológicos.
Resumo:
OBJECTIVE To assess the digital educational technology interface Caring for the sensory environment in the neonatal unit: noise, lighting and handling based on ergonomic criteria. METHODS Descriptive study, in which we used the guidelines and ergonomic criteria established by ISO 9241-11 and an online Likert scale instrument to identify problems and interface qualities. The instrument was built based on Ergolist, which follows the criteria of ISO 9141-11. There were 58 undergraduate study participants from the School of Nursing of Ribeirao Preto, University of Sao Paulo, who attended the classes about neonatal nursing content. RESULTS All items were positively evaluated by more than 70% of the sample. CONCLUSION Educational technology is appropriate according to the ergonomic criteria and can be made available for teaching nursing students.