5 resultados para DIC,FEM,Scarpone da sci,progettazione,riciclo,caratterizzazione materiale
em Scielo Saúde Pública - SP
Resumo:
A headspace solid-phase microextraction (HS-SPME) for the determination of 1,4 dioxane in cosmetics by gas chromatography is described. A manual SPME holder with 85 µm polyacrylate coating is utilized. The method is determined to have good resolution, satisfactory linerity (correlation coefficient r=0.997 for 0.20-10.00 mg Kg-1 range), a relative standard deviation of 6.3% and a detection limit of 5.00 µg Kg-1. Some cosmectic products were analyzed.
Resumo:
Methyl ethyl ketone (MEK) is a solvent commonly used in chemical, paint and shoe industry. The aim of this study was to develop and validate a method for urinary quantification of MEK, employing headspace solid phase micro extraction sampling (SPME) coupled to gas chromatography with flame ionization detection (GC-FID). The calibration curve (y=4.6851x-0.0011) presented good linearity with r²=0.9993. Accuracy (94-109%), intra-assay precision (4.07-5.91%) and inter-assay precision (3.03-5.62%) were acceptable. The quantification limit was 0.19 mg/L. This low cost method can be used routinely in the biological monitoring of occupational exposure to MEK, according to the requirements of the Brazilian legislation.
Resumo:
The estimation of measurement uncertainty of an analytical result is an important tool to be applied for compliance to ISO IEC 17025. Through the available guides it is possible to establish procedures and criteria for the estimation of measurement uncertainty. This paper presents a case study on the estimation of measurement uncertainty in migration the test of ε-caprolactam from the polyamide 6 packages to fatty foods with determination by GC-FID. The calculation methodology used for the estimation of measurement uncertainty for the migration test was developed based on the guides EURACHEM / CITAC and ISO GUM, taking into account relevant aspects of the migration test. The expanded uncertainty estimated was approximately 23% of the concentration of migration.
Resumo:
In this article a two-dimensional transient boundary element formulation based on the mass matrix approach is discussed. The implicit formulation of the method to deal with elastoplastic analysis is considered, as well as the way to deal with viscous damping effects. The time integration processes are based on the Newmark rhoand Houbolt methods, while the domain integrals for mass, elastoplastic and damping effects are carried out by the well known cell approximation technique. The boundary element algebraic relations are also coupled with finite element frame relations to solve stiffened domains. Some examples to illustrate the accuracy and efficiency of the proposed formulation are also presented.