12 resultados para Continuous Flow Automated Analysis (Gordon et al., 1993, WOCE Tech Rpt 93-1)

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work considers the modeling of turbulent flow in radial diffuser with axial feeding. Due to its claimed capability to predict flow including features such as separation, curvature and adverse pressure gradient, the RNG k-epsilon model of Orzag et al. (1993) is applied in the present analysis. The governing equations are numerically solved using the finite volume methodology. Experiments were conducted to assess the turbulence model. Numerical results of pressure distribution on the front disk surface for different flow conditions when compared to the experimental data indicated that the RNG k-epsilon model is adequate to predict this class of flow.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study, the performance of Immunomagnetic Separation technique, coupled with Immunofluorescence (IMS-IFA), was compared with the FAUST et al. and Lutz parasitological techniques for the detection of Giardia lamblia cysts in human feces. One hundred and twenty-seven samples were evaluated by the three techniques at the same time showing a rate of cyst detection of 27.5% by IMS-IFA and 15.7% by both Faust et al. and Lutz techniques. Data analysis showed a higher sensitivity of IMS-IFA for the detection of G. lamblia cysts in comparison with the techniques of FAUST et al. and Lutz. The use of this methodology as a routine procedure enables the processing of many samples simultaneously, in order to increase recovery rate of G. lamblia cysts and reduce the time of sample storage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A eficiência do uso de uma alça metálica para a remoção de elementos parasitários flutuantes foi investigada. A quantidade de elementos removidos a cada alçada sucessiva foi confrontada com um modelo logarítmico, o qual indicou que cada alçada retirou cerca de 30% dos elementos parasitários flutuantes remanescentes. Estimou-se que as 5 primeiras alçadas retiraram um total de 83% dos elementos parasitários flutuantes, sendo este um procedimento adequado para o método sob investigação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A member of the Lutzomyia flaviscutellata complex from Rondônia and southern Amazonas States, Brazil, is so close to the Venezuelan Lutzomyia olmeca recuta Feliciangeli et al., 1988, that it is regarded as belonging to the same species. Since this phlebotomine co-extis with L. olmeca nociva in Brazil, the subspecific status of the former is untenable and is rased to specific rank, as Lutzomyia reducta. The Brazilian material is described and illustrated, and compared with specimens of L. o. nociva and L. flaviscutellata from the same area. Keys to the known taxa of the flaviscutellata complex are presented. Leishmania amazonensis was isolated from one heavily infected specimen of L. reducta, making this the third species of the flaviscutellata complex to be implicated as a vector of this parasite in Brazil. The relative abundance of the three sympatric flaviscutellata complex species varies locally and appears to be related to soil drainage. L. reducta constituted about 25% if all phlebotomines captured in Disney traps at poorly drained and well drained site, but appears not to coloniza areas subject to periodic flooding. L. olmeca nociva was restricted to poorly drained areas not subject to flooding, whereas L. flaviscutellata was ubiquitous L. reducta has never been detected north of the Amazon river in Brazil, but absence of recosrds from western and northwestern Amazonas State may reflect lack of collecting in these areas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this paper is to propose a protocol to analyze blood samples in yellow fever 17DD vaccinated which developed serious adverse events. We investigated whether or not the time between sample collection and sample processing could interfere in lymphocyte subset percentage, for it is often impossible to analyze blood samples immediately after collection due to transport delay from collection places to the flow cytometry facility. CD4+CD38+ T, CD8+CD38+ T, CD3+ T, CD19+ B lymphocyte subsets were analyzed by flow cytometry in nine healthy volunteers immediately after blood collection and after intervals of 24 and 48 h. The whole blood lysis method and gradient sedimentation by Histopaque were applied to isolate peripheral blood mononuclear cells for flow cytometry analyses. With the lysis method, there was no significant change in lymphocyte subset percentage between the two time intervals (24 and 48 h). In contrast, when blood samples were processed by Histopaque gradient sedimentation, time intervals for sample processing influenced the percentage in T lymphocyte subsets but not in B cells. From the results obtained, we could conclude that the whole blood lysis method is more appropriate than gradient sedimentation by Histopaque for immunophenotyping of blood samples collected after serious adverse events, due to less variation in the lymphocyte subset levels with respect to the time factor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rate of carbon dioxide production is commonly used as a measure of microbial activity in the soil. The traditional method of CO2 determination involves trapping CO2 in an alkali solution and then determining CO2 concentration indirectly by titration of the remaining alkali in the solution. This method is still commonly employed in laboratories throughout the world due to its relative simplicity and the fact that it does not require expensive, specific equipment. However, there are several drawbacks: the method is time-consuming, requires large amounts of chemicals and the consistency of results depends on the operator's skills. With this in mind, an improved method was developed to analyze CO2 captured in alkali traps, which is cheap and relatively simple, with a substantially shorter sample handling time and reproducibility equivalent to the traditional titration method. A comparison of the concentration values determined by gas phase flow injection analysis (GPFIA) and titration showed no significant difference (p > 0.05), but GPFIA has the advantage that only a tenth of the sample volume of the titration method is required. The GPFIA system does not require the purchase of new, costly equipment but the device was constructed from items commonly found in laboratories, with suggestions for alternative configurations for other detection units. Furthermore, GPFIA for CO2 analysis can be equally applied to samples obtained from either the headspace of microcosms or from a sampling chamber that allows CO2 to be released from alkali trapping solutions. The optimised GPFIA method was applied to analyse CO2 released from degrading hydrocarbons from a site contaminated by diesel spillage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An evaluation of the performance of a continuous flow hydride generator-nebulizer for flame atomic absorption spectrometry was carried out. Optimization of nebulizer gas flow rate, sample acid concentration, sample and tetrahydroborate uptake rates and reductant concentration, on the As and Se absorbance signals was carried out. A hydrogen-argon flame was used. An improvement of the analytical sensitivity relative to the conventional bead nebulizer used in flame AA was obtained (2 (As) and 4.8 (Se) µg L-1). Detection limits (3σb) of 1 (As) and 1.3 (Se) µg L-1 were obtained. Accuracy of the method was checked by analyzing an oyster tissue reference material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow-injection system with sample and reagent addition by the synchronous merging zones approach for calcium determination in milk by flame AAS is proposed. Main parameters were optimized using a factorial design with central point. The optimum conditions were 2.5% (m/v) for La concentration, 8 mL min-1 for the carrier flow-rate, 20 cm for coiled reactor and 250 ìL for sample volume. Different sample preparation procedures were evaluated such as dilution in water or acid and microwave-assisted decomposition using concentrated or diluted acids. The optimized flow system was applied to determine Ca in eleven commercial milk samples and two standard reference materials diluted in water. Similar calcium levels were encountered comparing the results obtained by the proposed method (dilution in water) with those obtained using microwave-oven digestion. Results obtained in two standard reference materials were in agreement at 95% confidence level with those certified. Recoveries of spiked samples were in the 93% - 116% range. Relative standard deviation (n = 12) was < 5.4% and the sample throughput was 150 measurements per hour, corresponding to a consumption of 250 µL of sample and 6.25 mg La per determination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow injection method for the quantitative analysis of vancomycin hydrochloride, C66H75Cl2N9O24.HCl (HVCM), based on the reaction with copper (II) ions, is presented. HVCM forms a lilac-blue complex with copper ions at pH≅4.5 in aqueous solutions, with maximum absorption at 555 nm. The detection limit was estimated to be about 8.5×10-5 mol L-1; the quantitation limit is about 2.5×10-4 mol L-1 and about 30 determinations can be performed in an hour. The accuracy of the method was tested through recovery procedures in presence of four different excipients, in the proportion 1:1 w/w. The results were compared with those obtained with the batch spectrophotometric and with the HPLC methods. Statistical comparison was done using the Student's procedure. Complete agreement was found at a 0.95 significance level between the proposed flow injection and the batch spectrophotometric methods, which present similar precision (RSD: 2.1 % vs. 1.9%).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2 determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or carbonate samples are injected in a buffer carrier solution, and then are mixed with phosphoric acid solution to generate CO2, which diffuses through a PTFE membrane, in order to be collected in an acceptor carrier fluid, pumped towards to detection cell, in which the optode was adapted. The proposed system presents two linear response ranges, from 1.0 x 10-3 to 1.0 x 10-2 mol l-1, and from 2.0 x 10-2 to 0.10 mol l-1. The sampling frequency was 11 sample h-1, with good repeatability (R.S.D < 4 %, n = 10). In flow conditions the optode lifetime was 170 h. The system was applied in the analysis of commercial mineral water and the results obtained in the hydrogen carbonate determination did not differ significantly from those obtained by potentiometry, at a confidence level of 95 %.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-human primates have constituted an important group among animals subjected to various studies. Ethological, evolutionary and paleontological studies have revealed changes in anatomical structures linked to the evolution of primates, considered in studies on the comparative anatomy between Cebus libidinosus and other neotropical monkeys or those from the Old World, and the detailed knowledge on their anatomy may represent an important factor for their preservation and protection when the animals are brought to veterinary clinics after accidents or illnesses. In terms of veterinary importance, sometimes these animals arrive in the veterinary medical clinics after accidents, needing surgery or clinical treatment, but the little data available on anatomy has impaired the correct proceedings. The main justification for studies on C. libidinosus, is due to little information about the anatomy related to C. libidinosus in Brazilian and worldwide scientific literature. In this study, the distribution, enervation and path of the femoral and sciatic nerves of the pelvic limb (thigh) of C. libidinosus were studied and these results were compared with literature on the anatomy of humans, chimpanzees and baboons. In general, the enervation model of the four primates is identical, but in specific terms, the differences in enervations indicate evolution convergence closer to the branch of baboons in the evolutionary tree, and these data corroborate other comparative studies in relation to the same primates to vessels, muscles and nerves. In conclusion, the nerve organization in the thigh of C. libidinosus is identical to baboon, chimpanzee and homo, but more similar to baboon. The specific differences found indicate an ancient phylogenic origin to C. libidinosus and baboons (data corroborated by other studies).