2 resultados para Container Trial System

em Scielo Saúde Pública - SP


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study aimed to verify the association between the contribution of energy systems during an incremental exercise test (IET), pacing, and performance during a 10-km running time trial. Thirteen male recreational runners completed an incremental exercise test on a treadmill to determine the respiratory compensation point (RCP), maximal oxygen uptake (V˙O2max), peak treadmill speed (PTS), and energy systems contribution; and a 10-km running time trial (T10-km) to determine endurance performance. The fractions of the aerobic (WAER) and glycolytic (WGLYCOL) contributions were calculated for each stage based on the oxygen uptake and the oxygen energy equivalents derived by blood lactate accumulation, respectively. Total metabolic demand (WTOTAL) was the sum of these two energy systems. Endurance performance during the T10-km was moderately correlated with RCP, V˙O2maxand PTS (P<@0.05), and moderate-to-highly correlated with WAER, WGLYCOL, and WTOTAL (P<0.05). In addition, WAER, WGLYCOL, and WTOTAL were also significantly correlated with running speed in the middle (P<0.01) and final (P<0.01) sections of the T10-km. These findings suggest that the assessment of energy contribution during IET is potentially useful as an alternative variable in the evaluation of endurance runners, especially because of its relationship with specific parts of a long-distance race.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work was to monitor the operational conditions of the transport of chilled and frozen foods during delivery within cities and to evaluate the impact of the door openings on the alteration of the internal temperature of the refrigerated environment. Several temperature and pressure sensors were used in a refrigerated container with two compartments and they were installed in the refrigeration system unit and on the internal and external surfaces of the container. After the monitoring tests, it was verified that door openings during deliveries resulted in a disturbance that raised the internal temperature of the refrigerated container above values recommended for adequate conservation of the products transported. Moreover, increasing the number of door openings promoted a cumulative effect on the internal temperature, mainly in the chilled food compartment of the container. It was concluded that the refrigeration system unit presented serious limitations with regard to the maintenance of the container's internal temperature during the actual distribution routine, since it does not possess enough instantaneous capacity to restore the temperature set-point between deliveries.