4 resultados para Conformal Invariance
em Scielo Saúde Pública - SP
Resumo:
Abstract Objective: To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Materials and Methods: Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results: The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation ( p = 0.037). A baseline rectal volume superior to 70 cm3 had a significant influence on the prostate motion in the anteroposterior direction ( p = 0.045). Conclusion: The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm3. Therefore, the treatment of patients with a rectal volume > 70 cm3 should be re-planned with appropriate rectal preparation.
Resumo:
The prone position can be used for the planning of adjuvant radiotherapy after conservative breast surgery in order to deliver less irradiation to lung and cardiac tissue. In the present study, we compared the results of three-dimensional conformal radiotherapy planning for five patients irradiated in the supine and prone position. Tumor stage was T1N0M0 in four patients and T1N1M0 in one. All patients had been previously submitted to conservative breast surgery. Breast size was large in three patients and moderate in the other two. Irradiation in the prone position was performed using an immobilization foam pad with a hole cut into it to accommodate the breast so that it would hang down away from the chest wall. Dose-volume histograms showed that mean irradiation doses reaching the ipsilateral lung were 8.3 ± 3.6 Gy with the patient in the supine position and 1.4 ± 1.0 Gy with the patient in the prone position (P = 0.043). The values for the contralateral lung were 1.3 ± 0.7 and 0.3 ± 0.1 Gy (P = 0.043) and the values for cardiac tissue were 4.6 ± 1.6 and 3.0 ± 1.7 Gy (P = 0.079), respectively. Thus, the dose-volume histograms demonstrated that lung tissue irradiation was significantly lower with the patient in the prone position than in the supine position. Large-breasted women appeared to benefit most from irradiation in the prone position. Prone position breast irradiation appears to be a simple and effective alternative to the conventional supine position for patients with large breasts, since they are subjected to lower pulmonary doses which may cause less pulmonary side effects in the future.
Resumo:
Abstract OBJECTIVE To analyze the evidences of construct validity of the Katz Index for the retrospective assessment of activities of daily living (ADL) by informants, to assist neuropathological studies in the elderly. METHOD A cross-sectional study analyzed the functional ability of ADL measure by the Katz Index, of 650 cases randomly selected from the Brazilian Brain Bank of the Ageing Brain Study Group (BBBABSG) database. Sample was divided in two subsamples for the analysis (N=325, each) and then stratified according to cognitive decline assessed by the Clinical Dementia Rating Scale (CDR). Factor analyses with calculations of internal consistency and invariance were performed. RESULTS Factor analysis evidenced a unidimensional instrument with optimal internal consistency, in all subgroups. Goodness of fit indices were obtained after two treatments of covariance, indicating adequacy of the scale for assessing ADL by informants. The scale is invariant to cognitive decline meaning that it can be used for subjects with or without cognitive impairment. CONCLUSION Katz Index is valid for the retrospective assessment of basic ADL by informants, with optimal reliability.
Resumo:
It is argued that the invariants associated to the First Law of Thermodynamics and to the concept of identical processes lead to a clear definition of heat and work. The conditions for heat and work to be invariant under a system-surroundings interchange are also investigated. Finally, examples are presented to illustrate the above conditions.