122 resultados para Color vision Evaluation tests
em Scielo Saúde Pública - SP
Resumo:
We evaluated the color vision of 24 subjects (41.6 ± 6.5 years; 6 females) who worked in fluorescent lamp industries. They had been occupationally exposed to mercury vapor (10.6 ± 5.2 years) and had been away from the source of exposure for 6.4 ± 4.04 years. Mean urinary concentration of mercury was 40.6 ± 36.4 µg/g creatinine during or up to 1 year after exposure and 2.71 ± 1.19 µg/g creatinine at the time of color vision testing or up to 1 year thereafter. All patients were diagnosed with chronic mercury intoxication, characterized by clinical symptoms and neuropsychological alterations. A control group (N = 36, 48.6 ± 11.9 years, 10 females, 1.5 ± 0.47 µg mercury/g creatinine) was subjected to the same tests. Inclusion criteria for both groups were Snellen VA 20/30 or better and absence of known ophthalmologic pathologies. Color discrimination was assessed with the Farnsworth D-15 test (D-15) and with the Lanthony D-15d test (D-15d). Significant differences were found between the two eyes of the patients (P < 0.001) in both tests. Results for the worst eye were also different from controls for both tests: P = 0.014 for D-15 and P < 0.001 for D-15d. As shown in previous studies, the D-15d proved to be more sensitive than the D-15 for the screening and diagnosis of the color discrimination losses. Since color discrimination losses were still present many years after the end of exposure, they may be considered to be irreversible, at least under the conditions of the present study.
Resumo:
We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55%) performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81%). Three gold miners and 1 riverine (4/19 subjects, 21%) performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50%), comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity.
Resumo:
Spectral sensitivities of visual systems are specified as the reciprocals of the intensities of light (quantum fluxes) needed at each wavelength to elicit the same criterion amplitude of responses. This review primarily considers the methods that have been developed for electrophysiological determinations of criterion amplitudes of slow-wave responses from single retinal cells. Traditional flash methods can require tedious dark adaptations and may yield erroneous spectral sensitivity curves which are not seen in such modifications as ramp methods. Linear response methods involve interferometry, while constant response methods involve manual or automatic adjustments of continuous illumination to keep response amplitudes constant during spectral scans. In DC or AC computerized constant response methods, feedback to determine intensities at each wavelength is derived from the response amplitudes themselves. Although all but traditional flash methods have greater or lesser abilities to provide on-line determinations of spectral sensitivities, computerized constant response methods are the most satisfactory due to flexibility, speed and maintenance of a constant adaptation level
Resumo:
The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus.
Resumo:
This study is integrated within a research line dedicated to evaluate different options to introduce mandarin in Spanish agro-food industries and in both national and international markets. The effects of different preservation liquids (sucrose solution, sucrose and ascorbic acid solution, grape, and grapefruit juices), soluble solids (10, 12, 14 ºBrix), and thermal processing (30 seconds at 98 ºC) on vitamin C, color, carotenoids and sensory quality of canned Satsuma mandarin segments were studied. The liquid preservation that presented the best results was grapefruit juice, which provided the highest vitamin C (323 mg.L-1) and total carotenoids (16.4 mg.L-1) contents (the main carotenoid found was β-cryptoxanthin), intense orange color, high thermal stability, and very good sensory quality (e.g. intense floral and fresh-mandarin aromas and low levels of off-flavors).
Resumo:
The effects of body condition recovery (BC), carcass electrical stimulation (ES), aging time (AT 7 - 14 days), and calcium chloride injection on the meat characteristics of Santa Inês ewes (±5 years old) slaughtered immediately after weaning or after the body condition recovery period were studied. The carcass temperature, pH, shear force (SF), cooking loss (CL), meat color (L*, a*, b*), and meat tenderness were evaluated. A completely randomized design in a 2 × 2 × 2 × 3 (BC × ES × CaCl2 × AT) factorial arrangement was used, and the sensory tenderness data were analyzed using the table of Minimum Number of Correct Answers for the Duo-Trio test. The body condition recovery reduces the shear force in 8%, increasing their tenderness. Electrical stimulation reduced the shear force (24%) and did not change the other parameters. The aging time (7 or 14 days) decreased the shear force (18-26%), effect that was enhanced by electrical stimulation, and it darkened the meat reducing lightness (L*) and increasing yellowness (b*). The treatment with CaCl2 was the most effective in tenderizing meat by reducing the shear force ( 35%); increasing the cooking loss (4.5%); and increasing L* and b* lightening the meat. The sensory evaluation of tenderness corroborates the findings of the experimental evaluation regarding the effect of the treatment with CaCl2 on the meat quality improvement. It was concluded that the treatments improve meat characteristics achieving better results when applied together.
Resumo:
The aim of this study was to determine the colorimetric and sensory characteristics of a fermented cured sausage containing ostrich meat (Struthio camelus) and pork meat. Four treatments were performed: one with no ostrich meat (TC) and the others containing 19.08 (T1), 38.34 (T2), and 57.60% (T3) of ostrich meat and pork meat. Colorimetric analyses were measuring L*, a*, b*, C*, and hº. Sensory analysis was conducted assessing color, aroma, flavor, and texture at the end of the sausages' processing. The sausages containing ostrich meat were statistically different from the control in the instrumental colorimetric analysis. In the sensory analysis, no significant differences were observed between the treatments for aroma, flavor, and texture. However, significant differences were found in the color of the sausages due to the high myoglobin content present in the ostrich meat, which resulted in a very dark color in the treatment with the highest percentage of this type of meat.
Resumo:
After vaccination with the live PF strain of Trypanosoma cruzi, 194 blood cultures were performed in 143 mice, 9 dogs, 5 Cebus monkeys and 7 human subjects. Some of these blood cultures were simultaneously done with xenodiagnosis, subinoculation in baby mice and/or culture of viscerae. The trypanosomes isolated from the few positive cases (6,1%) were incapable of infecting baby mice were considered as cases of immunotolerance. All the other tests were negative.
Resumo:
Introduction Since the launch of the Global Programme to Eliminate Lymphatic Filariasis, more than 70% of the endemic countries have implemented mass drug administration (MDA) to interrupt disease transmission. The monitoring of filarial infection in sentinel populations, particularly schoolchildren, is recommended to assess the impact of MDA. A key issue is choosing the appropriate tools for these initial assessments (to define the best intervention) and for monitoring transmission. Methods This study compared the pre-MDA performance of five diagnostic methods, namely, thick film test, Knott's technique, filtration, Og4C3-ELISA, and the AD12-ICT card test, in schoolchildren from Brazil. Venous and capillary blood samples were collected between 11 pm and 1 am. The microfilarial loads were analyzed with a negative binomial regression, and the prevalence and associated 95% confidence intervals were estimated for all methods. The accuracies of the AD12-ICT card and Og4C3-ELISA tests were assessed against the combination of parasitological test results. Results A total of 805 schoolchildren were examined. The overall and stratified prevalence by age group and gender detected by Og4C3-ELISA and AD12-ICT were markedly higher than the prevalence estimated by the parasitological methods. The sensitivity of the AD12-ICT card and Og4C3-ELISA tests was approximately 100%, and the positive likelihood ratios were above 6. The specificity of the Og4C3-ELISA was higher than that of the AD12-ICT at different prevalence levels. Conclusions The ICT card test should be the recommended tool for monitoring school-age populations living in areas with ongoing or completed MDA.
Resumo:
The passive haemagglutination (PHA) test, enzyme-linked immunosorbent assay (ELISA) and the dot enzyme-immunosorbent assay (DOT-ELISA) were used to detect the levels of IgG antibodies against the Fraction 1 (F1) antigen of Yersinia pestis in sera of plague-infected patients from Northeast Brazil. Twenty three selected PHA-positive sera of subjects with bacteriological confirmation of plague were also positive in the DOT-ELISA but only 19 were detected by the conventional ELISA technique. Another group of 186 serum samples from subjects diagnosed as plague-infected by clinical and epidemiological parameters, but PHA-negative, were screened with DOT-ELISA and 11 gave positive results. The specificity of the assays on the serological detection of plague was confirmed in inhibition tests using purified F1 antigen. These results suggest that DOT-ELISA can be an useful, simple and more sensitive alternative for the serodiagnosis of plague in Northeast Brazil.
Resumo:
Specific IgG and IgM responses to soluble egg antigen (SEA) and keyhole limpet haemocyanin (KLH) were measured by ELISA in patients with acute and chronic schistosomiasis. The tests based upon IgM and IgG antibodies responses to KLH presented the best diagnostic discrimination, and can be used in conjunction with clinical and epidemiological data to the differential diagnosis of acute schistosomiasis.
Resumo:
This study was conducted to compare among the most recent generation of five screening tests licensed in Argentina, in order to evaluate which of the tests has the best sensitivity for detection of antibodies against hepatitis C virus (HCV). The tests analyzed were: Detect-HCV™ (3.0) Biochem ImmunoSystems, Canada; Hepatitis C EIA Wiener Lab., Argentina; Equipar HCV Ab, Italy; Murex HCV 4.0, UK and Serodia-HCV particles agglutination test, Japan. The results obtained showed high discrepancy between the different kits used and show that some of the tests assessed have a low sensitivity for anti-HCV detection in both chronic infections and early seroconversion, and indicate that among the commercially available kits in Argentina, Murex HCV 4.0 (UK) and Serodia-HCV particles agglutination test (Japan) have the best sensitivity for HCV screening. Although the sensitivity of the assays is the first parameter to be considered for blood screening, more studies should be carried out to assess the specificity of such assays.
Resumo:
This work presents the implementation and comparison of three different techniques of three-dimensional computer vision as follows: • Stereo vision - correlation between two 2D images • Sensorial fusion - use of different sensors: camera 2D + ultrasound sensor (1D); • Structured light The computer vision techniques herein presented took into consideration the following characteristics: • Computational effort ( elapsed time for obtain the 3D information); • Influence of environmental conditions (noise due to a non uniform lighting, overlighting and shades); • The cost of the infrastructure for each technique; • Analysis of uncertainties, precision and accuracy. The option of using the Matlab software, version 5.1, for algorithm implementation of the three techniques was due to the simplicity of their commands, programming and debugging. Besides, this software is well known and used by the academic community, allowing the results of this work to be obtained and verified. Examples of three-dimensional vision applied to robotic assembling tasks ("pick-and-place") are presented.