144 resultados para Color Doppler

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to differentiate benign ovarian tumors from malignant ones before surgery using color and pulsed Doppler sonography, and to compare results obtained before and after use of contrast medium, thereby verifying whether contrast results in an improvement in the diagnostic sensitivity. METHODS: Sixty two women (mean age 49.9 years) with ovarian tumors were studied, 45 with benign and 17 with malignant tumors. All women underwent a transvaginal color Doppler ultrasonographic exam. A study of the arterial vascular flow was made in all tumor areas, as well as an impedance evaluation of arterial vascular flow using the resistance index. RESULT: Localization of the vessels in the tumor revealed a greater proportion of malignant tumors with detectable internal vascular flows (64%) than benign tumors with such flows (22%). There was a considerable overlap of these findings. The use of contrast identified a greater number of vessels with confirmation in the totality of tumors, but did not improve the Doppler capacity in tumoral differentiation. Malignant tumors presented lower values of resistance index than the benign ones, whether or not contrast was used. The cutoff value for resistance index that better maximized the Doppler sensitivity and specificity was 0.55. Through this value, an increase of the sensitivity after contrast use was obtained, varying from 47% to 82%, while specificity remained statistically unchanged. CONCLUSION: Although the injection of a microbubble agent improved the sensitivity of the method detecting vascularization of tumors, a positive finding for vascularization by this method was not clinically useful in the differentiation of benign and malignant ovarian tumors.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a reprodutibilidade interobservador dos índices de vascularização do Doppler de amplitude tridimensional (Doppler de amplitude 3D) no primeiro trimestre de gestação. MATERIAIS E MÉTODOS: Realizou-se estudo de reprodutibilidade com 32 gestantes normais entre 7 e 10 semanas e 6 dias. Para o cálculo do volume tridimensional dos embriões utilizou-se o método VOCAL (Virtual Organ Computer-aided AnaLysis) com ângulo de rotação de 12°. Em seguida obtiveram-se, automaticamente, os três índices vasculares do Doppler de amplitude 3D: índice de vascularização (VI), índice de fluxo (FI) e índice de vascularização e fluxo (VFI). Para o cálculo da variabilidade interobservador, um examinador realizou uma segunda medida dos 32 embriões e um segundo examinador realizou uma terceira medida dos mesmos volumes, ambos desconhecendo os resultados do outro. Utilizaram-se, para análise estatística, o coeficiente de correlação intraclasse (CCI) e gráficos de Bland-Altman. RESULTADOS: Observou-se boa reprodutibilidade interobservador dos três índices vasculares. O VI apresentou CCI = 0,9 e média da diferença = -1,1; o FI apresentou CCI = 0,9 e média da diferença = -0,5; e o VFI apresentou CCI = 0,9 e média da diferença = -1,1. CONCLUSÃO: Os índices vasculares do Doppler de amplitude 3D do embrião no primeiro trimestre de gestação foram altamente reprodutíveis, em especial o FI.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D) reconstruction. METHODS: Three-dimensional (3D) image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS: Twenty patients were studied consecutively. The following cardiac diseases were present: valvar prostheses-6 (2 mitral, 2 aortic and 2 mitral and aortic); mitral valve prolapse- 3; mitral and aortic disease - 2; aortic valve disease- 5; congenital heart disease- 3 (2 atrial septal defect- ASD - and 1 transposition of the great arteries -TGA); arteriovenous fistula- 1. In 7 patients, color Doppler was also obtained and used for 3D flow reconstruction. Twenty five cardiac structures were acquired and 60 reconstructions generated (28 of mitral valves, 14 of aortic valves, 4 of mitral prostheses, 7 of aortic prostheses and 7 of the ASD). Fifty five of 60 (91.6%) reconstructions were considered of good quality by 2 independent observers. The 11 reconstructed mitral valves/prostheses and the 2 reconstructed ASDs provided more anatomical information than two dimensional echocardiography (2DE) alone. CONCLUSION: 3D echocardiography using a transesophageal transducer is a feasible technique, which improves detection of anatomical details of cardiac structures, particularly of the mitral valve and atrial septum.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The authors consider the possibility of using color Doppler of the ductus venosus and the measurement of nuchal translucency as a screening test for alterations in fetal cardiac functions in the first trimester of gestation. Review of the literature suggests that the combination of the ultrasonographic measurement of nuchal translucency and Doppler at 10 and 14 weeks of gestation can be effective in detecting certain cardiac abnormalities. This conclusion, however, is preliminary and needs to be further investigated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To describe echocardiographic measurements and left ventricular mass in a population sample of healthy adults inhabitants of the urban region of Porto Alegre. METHODS: An analytical, observational, population-based, cross-sectional study was done. Through a multi-stage probability sample, 114 individuals were selected to be submitted to a M-mode and two-dimensional echocardiogram with color Doppler. The analyses were restricted to healthy participants. Echocardiographic measurements were described by mean, standard deviation, 95 percentile and 95% confidence limits. RESULTS: A total of 100 healthy participants, with several characteristics similar to those from the original population, had a complete and reliable echocardiographic examination. The measurements of aorta, left atrium, interventricular septum, left ventricle in systole and diastole, left posterior wall and left ventricular mass, adjusted or not for body surface area or height, were significantly higher in males. The right ventricle size was similar among the genders. Several echocardiographic measurements were within standard normal limits. Interventricular septum, left posterior wall and left ventricular mass, adjusted or not for anthropometric measurements, and aortic dimensions had lower mean and range than the reference limits. CONCLUSION: The means and estimates of distribution for the measurements of interventricular septum, left posterior wall and left ventricular mass found in this survey were lower than those indicated by the international literature and accepted as normal limits.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Processos patológicos dos testículos são muito comuns, incluindo-se lesões tumorais e não-tumorais neste contexto. A ultra-sonografia com transdutor de alta freqüência tornou-se a modalidade de imagem de escolha para a avaliação desses órgãos. Este método ajuda a melhor caracterizar lesões intratesticulares e em muitas situações sugere um diagnóstico mais específico, principalmente nos casos em que há manifestações clínicas similares, tais como dor, inchaço e aumento volumétrico locais. O mapeamento com Doppler colorido é importantíssimo para demonstrar padrões anormais de perfusão testicular e auxilia no diagnóstico de condições clínicas agudas. Neste ensaio iconográfico os autores sumarizam os mais comuns achados clínicos, patológicos e as principais características diagnósticas de lesões testiculares, tais como microlitíase, cisto simples, espermatocele, varicocele, ectasia tubular da rete testis, orquite, hematomas e condições mais raras. A familiaridade com as características ecográficas e clínicas destas alterações é essencial para o estabelecimento do diagnóstico correto e início da terapêutica mais eficaz, quando necessária.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Determinar uma curva de referência baseada em múltiplos da mediana para o pico de velocidade sistólica da artéria cerebral média fetal. MATERIAIS E MÉTODOS: Realizou-se estudo de corte transversal com 143 gestantes normais entre 23 e 35 semanas. Realizou-se varredura bidimensional em corte axial do crânio fetal, incluindo os tálamos e o septo pelúcido, e em seguida acionou-se o modo color Doppler, visualizando-se a artéria cerebral média. O Doppler pulsátil foi disposto próximo à origem deste vaso, utilizando-se ângulo de insonação de menos de 20°. Para avaliar a correlação do pico de velocidade sistólica da artéria cerebral média com a idade gestacional, utilizou-se o coeficiente de correlação de Person (r). Por meio de modelos de regressão, construiu-se uma tabela de múltiplos da mediana para o pico de velocidade sistólica da artéria cerebral média em cada idade gestacional avaliada, e adicionalmente determinaram-se valores de referência para essa variável. RESULTADOS: Observou-se forte correlação entre o pico de velocidade sistólica da artéria cerebral média e a idade gestacional (r = 0,70; p = 0,001). Determinaram-se valores do pico de velocidade sistólica da artéria cerebral média para os seguintes múltiplos da mediana: 1,0; 1,29; 1,5; 1,55. Determinaram-se os percentis 2,5 e 97,5 para o pico de velocidade sistólica da artéria cerebral média, variando de 24,33 cm²/s a 78,36 cm²/s. CONCLUSÃO: Um nomograma do pico de velocidade sistólica da artéria cerebral média fetal foi determinado.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To study the stenosis of the carotid arteries in patients with symptomatic peripheral arterial disease.Methods: we assessed 100 consecutive patients with symptomatic peripheral arterial disease in stages of intermittent claudication, rest pain or ulceration. Carotid stenosis was studied by echo-color-doppler, and considered significant when greater than or equal to 50%. We used univariate analysis to select potential predictors of carotid stenosis, later taken to multivariate analysis.Results: The prevalence of carotid stenosis was 84%, being significant in 40% and severe in 17%. The age range was 43-89 years (mean 69.78). Regarding gender, 61% were male and 39% female. Half of the patients had claudication and half had critical ischemia. Regarding risk factors, 86% of patients had hypertension, 66% exposure to smoke, 47% diabetes, 65% dyslipidemia, 24% coronary artery disease, 16% renal failure and 60% had family history of cardiovascular disease. In seven patients, there was a history of ischemic cerebrovascular symptoms in the carotid territory. The presence of cerebrovascular symptoms was statistically significant in influencing the degree of stenosis in the carotid arteries (p = 0.02 at overall assessment and p = 0.05 in the subgroups of significant and non-significant stenoses).Conclusion: the study of the carotid arteries by duplex scan examination is of paramount importance in the evaluation of patients with symptomatic peripheral arterial disease, and should be systematically conducted in the study of such patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a artéria subclávia direita durante a ecografia do primeiro trimestre, descrever a técnica para a sua avaliação e, em caso de identificação de artéria subclávia direita aberrante (ARSA), determinar sua associação com alterações cromossómicas e/ou malformações cardíacas e sua orientação. MÉTODOS: Estudo prospectivo que consistiu na avaliação da artéria subclávia direita no primeiro trimestre (comprimento crânio caudal entre 45 e 84 milímetros), em todas as gestações únicas, consecutivas, por um único examinador, ecógrafo Voluson E8 (GE Healthcare, Zipf, Áustria) com sonda transabdominal RAB 4-8-D, 2 a 8 MHz, por um período não superior a 2 minutos, numa população geral de baixo risco. Com a ajuda do power/color Doppler, a artéria subclávia direita foi classificada como normal ou aberrante. Foi utilizada análise de regressão estatística (IBM SPSS Statistics for Windows, versão 20.0) para estudar o grau de associação entre a falha na avaliação/classificação da artéria subclávia direita e o comprimento crânio-caudal fetal e o índice de massa corporal materno. RESULTADOS: A mediana da idade materna foi de 30 anos (variando entre 17 e 43 anos) e a mediana do tempo de gestação no momento da avaliação da artéria subclávia direita foi de 12 semanas de gestação (variando entre 11 e 13 semanas de gestação). A avaliação da artéria subclávia direita foi possível em 138/176 (78,4%) dos casos. ARSA foi diagnosticada em um único caso (0,7%). Esse feto com ARSA também apresentou um foco hiperecogênico no ventrículo cardíaco esquerdo. Foi realizada ecocardiografia fetal às 16 semanas de gestação, que confirmou o diagnóstico de ARSA e foco hiperecogênico. A amniocentese revelou cariótipo normal, 46, XX. CONCLUSÃO: É possível fazer o diagnóstico de ARSA na ecografia do primeiro trimestre. O nosso único caso de ARSA apresentou um cariótipo normal sem malformações cardíacas associadas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract:Two ultrasound based fertility prediction methods were tested prior to embryo transfer (ET) and artificial insemination (AI) in cattle. Female bovines were submitted to estrous synchronization prior to ET and AI. Animals were scanned immediately before ET and AI procedure to target follicle and corpus luteum (CL) size and vascularity. In addition, inseminated animals were also scanned eleven days after insemination to target CL size and vascularity. All data was compared with fertility by using gestational diagnosis 35 days after ovulation. Prior to ET, CL vascularity showed a positive correlation with fertility, and no pregnancy occurred in animals with less than 40% of CL vascularity. Prior to AI and also eleven days after AI, no relationship with fertility was seen in all parameters analyzed (follicle and CL size and vascularity), and contrary, cows with CL vascularity greater than 70% exhibit lower fertility. In inseminated animals, follicle size and vascularity was positive related with CL size and vascularity, as shown by the presence of greater CL size and vascularity originated from follicle with also greater size and vascularity. This is the first time that ultrasound based fertility prediction methods were tested prior to ET and AI and showed an application in ET, but not in AI programs. Further studies are needed including hormone profile evaluation to improve conclusion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To verify the hypothesis that the pulmonary vein pulsatility index is higher in fetuses of diabetic mothers than it is in normal fetuses of nondiabetic mothers. METHODS: Twenty-four fetuses of mothers with either gestational or previous diabetes (cases), and 25 normal fetuses of mothers without systemic disease (control) were examined. Fetuses were examined through prenatal Doppler and color flow mapping. The pulmonary vein pulsatility index was obtained by placing the pulsed Doppler sample volume over the right superior pulmonary vein and applying the formula (systolic velocity - presystolic velocity)/mean velocity. RESULTS: The mean gestational age of the study fetuses was 30.3±2.7 weeks, and gestational age of the controls was 29±3.3 weeks, with no significant difference in gestational age between groups (p=0.14). Fetuses of diabetic mothers had a mean pulmonary vein pulsatility index of 1.6±1, and those of the control group had an index of 0.86±0.27. CONCLUSION: Fetuses of diabetic mothers had pulmonary vein pulsatility indexes (parameter easily obtained through Doppler echocardiography that may be related to fetal diastolic function) higher than those in fetuses of mothers with normal glycemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To establish reference values for the first trimester uterine artery resistance index (UtA-RI) and pulsatility index (UtA-PI) in healthy singleton pregnant women from Northeast Brazil. METHODS: A prospective observational cohort study including 409 consecutive singleton pregnancies undergoing routine early ultrasound screening at 11 - 14 weeks of gestation was performed. The patients responded to a questionnaire to assess maternal epidemiological characteristics. The left and right UtA-PI and UtA-RI were examined by color and pulsed Doppler by transabdominal technique and the mean UtA-PI, mean UtA-RI and the presence of bilateral protodiastolic notching were recorded. Quartile regression was used to estimate reference values. RESULTS: The mean±standard deviation UtA-RI and UtA-PI were 0.7±0.1 and 1.5±0.5, respectively. When segregated for gestation age, mean UtA-PI was 1.6±0.5 at 11 weeks, 1.5±0.6 at 12 weeks, 1.4±0.4 at 13 weeks and 1.3±0.4 at 14 weeks' gestation and mean UtA-RI was 0.7±0.1 at 11 weeks, 0.7±0.1 at 12 weeks, 0.6±0.1 at 13 weeks and 0.6±0.1 at 14 weeks' gestation. Uterine artery bilateral notch was present in 261 (63.8%) patients. We observed that the 5th and 95th percentiles of the UtA-PI and UtA-RI uterine arteries were 0.7 and 2.3 and, 0.5 and 0.8, respectively. CONCLUSION: Normal reference range of uterine artery Doppler in healthy singleton pregnancies from Northeast Brazil was established. The 95th percentile of UtA-PI and UtA-RI values may serve as a cut-off for future prediction of pregnancy complications studies (i.e., pre-eclampsia) in Northeast Brazil.