22 resultados para Closed-loop recycling

em Scielo Saúde Pública - SP


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study was to model mathematically and to simulate the dynamic behavior of an auger-type fertilizer applicator (AFA) in order to use the variable-rate application (VRA) and reduce the coefficient of variation (CV) of the application, proposing an angular speed controller θ' for the motor drive shaft. The input model was θ' and the response was the fertilizer mass flow, due to the construction, density of fertilizer, fill factor and the end position of the auger. The model was used to simulate a control system in open loop, with an electric drive for AFA using an armature voltage (V A) controller. By introducing a sinusoidal excitation signal in V A with amplitude and delay phase optimized and varying θ' during an operation cycle, it is obtained a reduction of 29.8% in the CV (constant V A) to 11.4%. The development of the mathematical model was a first step towards the introduction of electric drive systems and closed loop control for the implementation of AFA with low CV in VRA.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present study shows the development, simulation and actual implementation of a closed-loop controller based on fuzzy logic that is able to regulate and standardize the mass flow of a helical fertilizer applicator. The control algorithm was developed using MATLAB's Fuzzy Logic Toolbox. Both open and closed-loop simulations of the controller were performed in MATLAB's Simulink environment. The instantaneous deviation of the mass flow from the set point (SP), its derivative, the equipment´s translation velocity and acceleration were all used as input signals for the controller, whereas the voltage of the applicator's DC electric motor (DCEM) was driven by the controller as output signal. Calibration and validation of the rules and membership functions of the fuzzy logic were accomplished in the computer simulation phase, taking into account the system's response to SP changes. The mass flow variation coefficient, measured in experimental tests, ranged from 6.32 to 13.18%. The steady state error fell between -0.72 and 0.13g s-1 and the recorded average rise time of the system was 0.38 s. The implemented controller was able to both damp the oscillations in mass flow that are characteristic of helical fertilizer applicators, and to effectively respond to SP variations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to analyze the economic viability of the third milking in production systems using mechanical milking in a closed circuit, aiming to provide technicians and farmers with information to assist them in decision-making. Specifically, it intended: (a) to estimate the cost of one milking; (b) to estimate the cost of the third milking; (c) to develop a mathematical equation to estimate the minimum amount of milk produced with two milkings, from which it would be economically feasible to do the third milking. Data were collected from three dairy farms, from November 2010 to March 2011, keeping a twice-a-day milking frequency, with three data collections in each farm, totalizing nine collections. Considering the average data, it would be feasible to do the third milking if the average milk yield per day of lactating cows in a twice-a-day milking frequency was greater than or equal to 24.43 kg of milk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A single and practical method to slain Malassezia furfur and Corynebacterium minutissimum in lesions' scales is described. The scales are collected by pressing small pieces of scotch tape (about 4 cm lenght and 2 cm width) onto the lesions and following withdrawl the furfuraceous scales will remain on the glue side. These pieces are then immersed for some minutes in lactophenol-cotton blue stain. Following absorption of the stain the scales are washed in current water to remove the excess of blue stain, dried with filter paper, dehydrated via passage in two bottles containing absolute alcohol and then placed in xylene in a centrifugation tube. The xylene dissolves the scotch tape glue and the scales fall free in the tube. After centrifugation and decantation the scales concentrated on the bottom of the tube are collected with a platinum-loop, placed in Canada balsam on a microscopy slide and closed with a cover slip. The preparations are then ready to be submitted to microscopic examination. Other stains may also be used instead of lactophenol-cotton blue. This method is simple, easily performed, and offers good conditions to study these fungi as well as being useful for the diagnosis of the diseases that they cause.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The loop-mediated isothermal amplification method (LAMP) is a recently developed molecular technique that amplifies nucleic acid under isothermal conditions. For malaria diagnosis, 150 blood samples from consecutive febrile malaria patients, and healthy subjects were screened in Thailand. Each sample was diagnosed by LAMP, microscopy and nested polymerase chain reaction (nPCR), using nPCR as the gold standard. Malaria LAMP was performed using Plasmodiumgenus and Plasmodium falciparum specific assays in parallel. For the genus Plasmodium, microscopy showed a sensitivity and specificity of 100%, while LAMP presented 99% of sensitivity and 93% of specificity. For P. falciparum, microscopy had a sensitivity of 95%, and LAMP of 90%, regarding the specificity; and microscopy presented 93% and LAMP 97% of specificity. The results of the genus-specific LAMP technique were highly consistent with those of nPCR and the sensitivity of P. falciparum detection was only marginally lower.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To characterize the cardiac electrophysiologic effects of cocaine. METHODS: In 8 dogs (9-13 kg), electrophysiologic parameters and programmed stimulation were undertaken using transvenous catheters at baseline, and after cocaine intravenous infusion (12 mg/kg bolus followed by 0.22 mg/kg/min for 25 minutes). RESULTS: Cocaine plasma levels (n=5) rose to 6.73± 0.56 mg/mL. Cocaine did not affect sinus cycle length and arterial pressure. Cocaine prolonged P wave duration (54±6 vs 73±4 ms, P<0.001), PR interval (115±17 vs 164±15 ms, P<0.001), QRS duration (62±10 vs 88±14 ms, P<0.001), and QTc interval (344±28 vs 403±62 ms, P=0.03) but not JT interval (193±35 vs 226±53 ms, NS). Cocaine prolonged PA (9±6 vs 23±8 ms, P<0.001), AH (73±16 vs 92±15 ms; P=0.03), and HV (35±5 vs 45±3ms; P<0.001) intervals and Wenckebach point (247±26 vs 280±28 ms, P=0.04). An increase occurred in atrial (138±8 vs 184± 20 ms; P<0.001) and ventricular (160±15 vs 187±25 ms; P=0.03) refractoriness at a cycle length of 300 ms. Atrial arrhythmias were not induced in any dog. Ventricular fibrillation (VF) was induced in 2/8 dogs at baseline and 4/8 dogs after cocaine. CONCLUSION: High doses of cocaine exert significant class I effects and seem to enhance inducibility of VF but not of atrial arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:The recording of arrhythmic events (AE) in renal transplant candidates (RTCs) undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used.Objective:We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR).Methods:A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE.Results:During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT) occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002), and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001) were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD) was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041).Conclusions:In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A closed Lutzomyia longipalpis colony, from Ceará has been used to transmit Leishmania chagasi isolated from a fox in Pará state. The last time this colony was successfully used in similar transmission experiments was eight years (64 generations) ago indicating that this colony of Lu. longipalpis has fully maintained its vectorial capacity in spite of such a long period of maintainance in the laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

What is the importance of open habitat in a predominantly closed forest to the dung beetle assemblage? The Atlantic Forest in Brazil is one of the most highly disturbed ecosystems and is mainly represented by fragmented areas. However, in places where human disturbances have ceased, certain areas are showing a natural regeneration pattern. The aim of the present study was to determine how the dung beetle assemblage responds to distinct habitat structures in a fragment of Atlantic Forest. For such, open and closed forest areas were sampled in a fragment of the Atlantic Forest in the northeastern region of Brazil. Pitfall traps baited with excrement and carrion were used to collect the beetles. A total of 7,267 individuals belonging to 35 species were captured. Canthon chalybaeus and C. mutabilis were restricted to open areas. Nearly 90% of the individuals of C. aff. simulans and Deltochilum aff. irroratum were identified in these areas. A higher percentage (> 50%) of Canthon staigi, Dichotomius aff. depressicolis and D. aff. sericeus occurred in closed areas. Abundance differed between areas, with higher values in closed areas. Richness was not influenced by the habitat structure. NMDS ordination exhibited the segregation of areas and ANOSIM confirmed that this variable explained the assemblage of dung beetle species. The findings of the present study validate that open areas are associated to more restrictive conditions, limiting a higher abundance of dung beetle. Although situated near preserved fragments, the studied open areas increase the heterogeneity of the general landscape.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A large variety of techniques have been used to measure soil CO2 released from the soil surface, and much of the variability observed between locations must be attributed to the different methods used by the investigators. Therefore, a minimum protocol of measurement procedures should be established. The objectives of this study were (a) to compare different absorption areas, concentrations and volumes of the alkali trapping solution used in closed static chambers (CSC), and (b) to compare both, the optimized alkali trapping solution and the soda-lime trapping using CSC to measure soil respiration in sugarcane areas. Three CO2 absorption areas were evaluated (7; 15 and 20 % of the soil emission area or chamber); two volumes of NaOH (40 and 80 mL) at three concentrations (0.1, 0.25 and 0.5 mol L-1). Three different types of alkaline traps were tested: (a), 80 mL of 0.5 mol L-1 NaOH in glass containers, absorption area 15 % (V0.5); (b) 40 mL of 2 mol L-1 NaOH retained in a sponge, absorption area 80 % (S2) and (c) 40 g soda lime, absorption area 15 % (SL). NaOH concentrations of 0.5 mol L-1 or lower underestimated the soil CO2-C flux or CO2 flux. The lower limit of the alkali trap absorption area should be a minimum of 20 % of the area covered by the chamber. The 2 mol L-1 NaOH solution trap (S2) was the most efficient (highest accuracy and highest CO2 fluxes) in measuring soil respiration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to test a closed soilless growing system for producing bare root transplants and runner tips of two strawberry clones, using two categories of substrates. The system used corrugated roofing panels of fiber-cement, over which a substrate layer was used as a growing bed. The nutrient solution was pumped from a reservoir toward the upper end of the roofing panels and drained back to a reservoir. Plant growth and development were determined for two advanced strawberry clones, grown in sand or in Plantmax organic substrate. Growth of the stock plants and the number and dry mass of bare root transplants were similar in the substrates, but bare roots differed in their crown diameters by substrate. For number of runner tips, no significant differences were found in total, small, and medium categories in the substrates. A mean production of about 590 runner tips per square meter and 145 bare root transplants per square meter was obtained. For both clones, a large number of bare root transplants and runner tips of adequate size were produced in the closed soilless growing system using sand or organic substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An important component for the automation of flow injection analysis (FIA) systems is the sample injection valve. A simple and inexpensive commutator with 16 pinch valves (8 normally open and 8 closed) was developed and configured as a multichannel injection valve. It is activated by a single solenoid of 3 Kgf, powered by a pulsed driver circuit, controlled by a microcomputer or a switch. FIA with spectrophometric detection of potassium dichromate solution was used for the evaluation of the new injection valve and its comparison with other valves, for sample loops of 50, 100, 200, 300 and 500 muL. The repeatability was favorable (RSD 1.0% for 15 injections at each loop volume) compared to a manual injector, an electropneumatic injector and an injector configured with three mini solenoid valves (RSD 1.1, 1.3 and 1.0%, respectively, for15 injections at each loop volume).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The utilization of organic wastes represents an alternative to recover degraded pasture. The experiment aimed to assess the changes caused by the provision of different organic waste (poultry litter, turkey litter and pig manure) in a medium-textured Oxisol in Brazilian Savanna under degraded pasture. It was applied different doses of waste compared to the use of mineral fertilizers and organic mineral and evaluated the effect on soil parameters (pH, organic matter, phosphorus and potassium) and leaf of Brachiariadecumbens (crude protein, phosphorus and dry mass production). It was observed that application of organic waste did not increase the level of soil organic matter and pH in the surface layer, and the application of turkey litter caused acidification at depths of 0.20-0.40 m and 0.40-0.60 m. There was an increase in P and K in the soil with the application of poultry litter and swine manure. All organic wastes increased the productivity of dry matter and crude protein and phosphorus. The recycling of nutrients via the application of organic waste allows efficiency of most parameters similar to those observed with the use of mineral sources, contributing to improving the nutritional status of soil-plantsystem.