3 resultados para Classified Driver Licensing.

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pyranthe acaciae Berg, 1883 and Hemiptycha chilensis Spinola, 1852 are reinstated in Sundarion Kirkaldy, 1904 (formerly in synonymy of Callicentrus bonasia (Fabricius, 1775) (Centrotinae, Nessorhinini)). Pyranthe frustratoria Berg, 1883 (also formerly considered as synonym of Callicentrus bonasia) becomes a new synonym of Sundarion flavomarginatum (Fairmaire, 1846).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Caesalpinia leiostachya (Benth.) Ducke (Caesalpiniaceae) is a Brazilian legumenous tree whose seeds present different sizes and shapes, with dormancy imposed by a waterproof coat. In order to improve that quality of lot, seeds were classified by width in sieves of circular meshes (13, 14, 15, 16 and 17) and manually separated by shape in elongate, round and angular. Masses of 1000 seeds were determined and the thickness of each width and shape seedclass was measured, and coat permeability of the seeds classified by the width was investigated. Seeds were scarified in concentrated sulphuric acid and submitted to the germination test. Both final percentage and speed of germination index were evaluated. The classification of the seeds improved the quality of the lot, and the coat permeability was not affected by seed width. Elongated-flat seeds are of low physiological quality and should be discarded. Masses of 1000 seeds, percentage final and speed of germination increased with the width of the seeds. Both elongated and angular seeds had similar germinative behavior, and round seeds are of greater thickness and of superior physiological quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the importance of the environment on animal production and thus environmental control, the study aims to build a system for monitoring and control the meteorological variables, temperature and relative humidity, low cost, which can be associated with an evaporative cooling system (ECS). The system development included all the stages of assembly, test and laboratory calibration, and later the validation of the equipment carried in the field. The validation step showed results which allowed concluding that the system can be safely used in the monitoring of these variables. The controller was efficient in management of the microclimate in the waiting corral and allowed the maintenance of the air temperature within the comfort range for dairy cattle in pre-milking with averaged 25.09 ºC during the afternoon. The equipment showed the lower cost (R$ 325.76) when compared to other middle market (R$ 450.00).