69 resultados para Chloride concentration profiles

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cystic fibrosis is a genetic disease usually diagnosed by abnormal sweat testing. We report a case of an 18-year-old female with bronchiectasis, chronic P. aeruginosa infection, and normal sweat chloride concentrations who experienced rapid decrease of lung function and clinical deterioration despite treatment. Given the high suspicion ofcystic fibrosis, broad genotyping testing was performed, showing a compound heterozygous with deltaF508 and 3849+10kb C->T mutations, therefore confirming cystic fibrosis diagnosis. Although the sweat chloride test remains the gold standard for the diagnosis of cystic fibrosis, alternative diagnostic tests such as genotyping and electrophysiologic measurements must be performed if there is suspicion of cystic fibrosis, despite normal or borderline sweat chloride levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Red wines from different countries have been assessed in order to determine the influence of terroir and grape variety in their concentration of chloride. Chloride analysis was carried out by Laboratório de Bebidas de Origem Vegetal do Espírito Santo (Labeves), using the potentiometric method, in which the dosing is directly applied to the sample with an Ag/AgCl electrode. Data were collected to establish the level of chloride, as presented in the analysis reports issued by Labeves, and to serve as a wine categorization database, according to grape variety and country of origin. Australia and Argentina presented the highest levels of chloride and the wines made from the Syrah variety presented the highest concentration of such ion. We have, therefore, found that terroir and grape variety do have an influence over the concentration of chloride in red wines.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents some results that may be used as previous considerations to a hydrogen peroxide electrogeneration process design. A kinetic study of oxygen dissolution in aqueous solution is carried out and rate constants for oxygen dissolution are calculated. Voltammetric experiments on vitreous carbon cathode shown that the low saturation concentration drives the oxygen reduction process to a mass transfer controlled process which exhibits low values of limiting currents. Results have shown that the hydrogen peroxide formation and its decomposition to water are separated by 400 mV on the vitreous carbon surface. Diffusion coefficients for oxygen and hydrogen peroxide are calculated using data taken from Levich and Tafel plots. In a series of bulk electrolysis experiments hydrogen peroxide was electrogenerated at several potential values, and concentration profiles as a function of the electrical charged passed were obtained. Data shown that, since limiting current plateaus are poorly defined onto reticulated vitreous carbon, cathodic efficiency may be a good criterion for choosing the potential value in which hydrogen peroxide electrogeneration should be carried out.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work the CCl4 degradation in aqueous solution by sonication with 40 kHz commercial ultrasonic bath was investigated. Sonochemical degradation of CCl4 occur by the cleavage of C-Cl bond into the cavitation bubbles. Oxidation reactions and the pH decreasing in the bulk solution during sonication were attributed to chlorine radicals produced by CCl4 sonolysis, leading to increase the chloride concentration. The formation of oxidizing agents was evaluated employing I- and Fe2+ ion solutions, converted to I2 and HIO, and Fe3+, respectively. The amount of chloride and hydronium ions produced after 3 min of irradiation was 11.52 and 12.19 mmol, respectively, suggesting that the same reaction was involved to produce these ions. Fe2+ oxidation and the pH variation were monitored to estimate chlorine radical formation rate in the presence (0.107 mumol s-1) and absence (0.092 mumol s-1) of metallic ion during the first minute of sonication.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Brazilian legislation requires analysis of certain parameters to classify a wine and allow its commercialization. Some physico-chemical and some color parameters were determined in this work in samples of different red wines sold in the metropolitan area of Recife. Multivariate analysis comprising principal component analysis and hierarchical cluster analysis was employed to distinguish the analyzed wines. The results for pH, chloride concentration, color parameters and ammonium content were the most important variables for sample classification. It was also possible to classify the wines as soft or dry wines and amongst the soft wines we could determine two out of four winegrowing producers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A study on the monitoring of glycerol oxidation catalyzed by gold nanoparticles supported on activated carbon under mild conditions by chemometric methods is presented. The reaction was monitored by mass spectrometry-electrospray ionization (ESI-MS) and comparatively by mid infrared spectroscopy (MIR). Concentration profiles of reagent and products were determined by chemometric tools such as Principal Component Analysis (PCA), Evolving Factor Analysis (EFA) and Multivariate Curve Resolution (MCR). The gold nanoparticle catalyst was relatively active in glycerol oxidation, favoring formation of high added value products. It was found that the reaction stabilization was reached at four hours, with approximately 70% glycerol conversion and high selectivity for glycerate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, we applied the free open source SCILAB software for the numerical integration of differential rate law equations to obtain the concentration profiles of chemical species involved in the kinetics of some complex reactions. An automated method was applied to construct the system of ordinary differential equations (ODE) from the postulated chemical models. The solutions of the ODEs were obtained numerically by standard SCILAB functions. We successfully simulated even complex chemical systems such as pH oscillators. This communication opens up the possibility of using SCILAB in simulations and modeling by our chemistry undergraduate students.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Chlorella sp. was used to assess algal lipid production with concentrated desalination. In order to investigate the action of the flocculating agent calcium chloride and pH, a Box-Behnken Design and a Central Composite Design (CCD) were carried out. Also, Soxhlet and Supercritical Fluid Extraction (SFE), with and without sonication lipid extraction methods, were examined. The optimal flocculation conditions were pH 10.0 and 2.0 g/L of calcium chloride concentration. The highest lipid content of Chlorella sp. was obtained using the Soxhlet extraction method. The most abundant fatty acid extracted by Soxhlet and SFE, with and without sonication, was palmitic acid, whose proportions were 57.4%, 35.3% and 25.5%, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electrodegradation of atrazine in water was performed using homemade (PA and PB) and purchased (PC) boron-doped diamond anodes. The degradation was monitored off-line by analyzing total organic carbon and high performance liquid chromatography with diode array detector (HPLC-DAD) and at-line by UV spectroscopy. The spectra were recorded every 2 min. The rank deficiency problem was resolved by assembling an augmented column-wise matrix. HPLC was employed to separate the original and byproducts degradation components. Aiming the same goal, multivariate curve resolution - alternating least squares (MCR-ALS) was applied to resolve the UV spectroscopic data. Comparison between HPLC and MCR-ALS separations is presented. By using MCR-ALS the spectra of atrazine and two byproducts were successfully resolved and the resulted concentration profiles properly represented the system studied. The ALS explained variance (R2) for PA, PB and PC was equal to 99.99% for all of them and the lack of fit for PA, PB and PC were 0.39, 0.34 and 0.54 respectively. The correlation (R) between the recovered and pure spectra were calculate for each electrodegradation, validating the MCR-ALS results. The average R was equal to 0.997. The spectral and concentration profiles described with this new approach are in agreement with HPLC-DAD results. The proposed method is an alternative to classical analyses for monitoring of the degradation process, mainly due to the simplicity, fast results and economy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents the experimental characterization of hydrodynamics and gas-liquid mass transfer in a three-phase fluidized bed containing polystyrene and nylon particles. The influence of gas and liquid velocities on phase holdups and volumetric gas-liquid mass transfer coefficient was investigated for flow conditions similar to those applied in biotechnological process. The phase holdups were obtained by the pressure profile technique. The volumetric gas-liquid mass transfer coefficient was obtained adjusting the experimental concentration profiles of dissolved oxygen in the liquid phase with the predictions of the axial dispersion model. According to experimental results the liquid holdup increases with the gas velocity, whereas the solid holdup decreases. The gas holdup increases significantly with the increase in gas velocity, and it shows for the three-phase fluidized bed comparable values or larger than those of bubble column. The volumetric gas-liquid mass transfer coefficient increases significantly with an increase in the air velocity for both bubble column and fluidized beds. In addition, in the operational condition of high liquid velocity, the presence of low-density particles in the bed increased the gas-liquid mass transfer, and thus the volumetric mass transfer coefficient values obtained in the fluidized bed were comparable or larger than those of bubble column.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

L-arabinose is widely used in food, medicine, chemistry, and biology fields; however, solubility and seeded metastable zone width (MSZW) of L-arabinose have not been reported in the literature. In this paper, solubility and MSZW of L-arabinose in aqueous solution were determined. Solubility of L-arabinose was measured in the range of 20-68 °C by a conventional equilibrium solubility method and quantitation was determined using the ion chromatography technique. Seeded MSZW was determined in the range of 51-73% by the calorimetric method. The effect of two salts (potassium chloride and calcium chloride) on the solubility and MSZW of L-arabinose were also evaluated. Results showed that both potassium chloride and calcium chloride increased the solubility of L-arabinose, and this increase was intensified with temperature rise. The MSZW of L-arabinose was not constant but a spread. Potassium chloride increased the MSZW of L-arabinose. However, the effect of calcium chloride on MSZW of L-arabinose was concentration dependent. Conclusion: the L-arabinose solubility increased with the increase in temperature, and both potassium chloride and calcium chloride increased the solubility of L-arabinose in aqueous solution. The seeded MSZW of L-arabinose is not a constant; it increases in the presence of potassium chloride and varies with the change in calcium chloride concentration.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Hyperchloremia is one of the multiple etiologies of metabolic acidosis in hemodialysis (HD) patients. The aim of the present study was to determine the influence of chloride dialysate on metabolic acidosis control in this population. We enrolled 30 patients in maintenance HD program with a standard base excess (SBE) ≤2 mEq/L and urine output of less than 100 mL/24 h. The patients underwent dialysis three times per week with a chloride dialysate concentration of 111 mEq/L for 4 weeks, and thereafter with a chloride dialysate concentration of 107 mEq/L for the next 4 weeks. Arterial blood was drawn immediately before the second dialysis session of the week at the end of each phase, and the Stewart physicochemical approach was applied. The strong ion gap (SIG) decreased (from 7.5 ± 2.0 to 6.2 ± 1.9 mEq/L, P = 0.006) and the standard base excess (SBE) increased after the use of 107 mEq/L chloride dialysate (from -6.64 ± 1.7 to -4.73 ± 1.9 mEq/L, P < 0.0001). ∆SBE was inversely correlated with ∆SIG during the phases of the study (Pearson r = -0.684, P < 0.0001) and there was no correlation with ∆chloride. When we applied the Stewart model, we demonstrated that the lower concentration of chloride dialysate interfered with the control of metabolic acidosis in HD patients, surprisingly, through the effect on unmeasured anions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Random amplified polymorphic DNA (RAPD) technique is a simple and reliable method to detect DNA polymorphism. Several factors can affect the amplification profiles, thereby causing false bands and non-reproducibility of assay. In this study, we analyzed the effect of changing the concentration of primer, magnesium chloride, template DNA and Taq DNA polymerase with the objective of determining their optimum concentration for the standardization of RAPD technique for genetic studies of Cuban Triatominae. Reproducible amplification patterns were obtained using 5 pmoL of primer, 2.5 mM of MgCl2, 25 ng of template DNA and 2 U of Taq DNA polymerase in 25 µL of the reaction. A panel of five random primers was used to evaluate the genetic variability of T. flavida. Three of these (OPA-1, OPA-2 and OPA-4) generated reproducible and distinguishable fingerprinting patterns of Triatominae. Numerical analysis of 52 RAPD amplified bands generated for all five primers was carried out with unweighted pair group method analysis (UPGMA). Jaccard's Similarity Coefficient data were used to construct a dendrogram. Two groups could be distinguished by RAPD data and these groups coincided with geographic origin, i.e. the populations captured in areas from east and west of Guanahacabibes, Pinar del Río. T. flavida present low interpopulation variability that could result in greater susceptibility to pesticides in control programs. The RAPD protocol and the selected primers are useful for molecular characterization of Cuban Triatominae.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water. Twelve organic acids and nine inorganic anions were separated without any interference from other compounds and carry-over problems between samples. The injection loop was replaced by a Dionex AC15 concentrator column. The proposed procedure employed an auto-sampler that injected 1.5 ml of sample into a KOH mobile phase, generated by an Eluent Generator, at 1.5 mL min-1, which carried the sample to the chromatographic columns (one guard column, model AG-15, and one analytical column, model AS15, with 250 x 4mm i.d.). The gradient elution concentrations consisted of a 10.0 mmol l-1 KOH solution from 0 to 6.5 min, gradually increased to 45.0 mmol l-1 KOH at 21 min., and immediatelly returned and maintained at the initial concentrations until 24 min. of total run. The compounds were eluted and transported to an electro-conductivity detection cell that was attached to an electrochemical detector. The advantage of using concentrator column was the capability of performing routine simultaneous determinations for ions from 0.01 to 1.0 mg l-1 organic acids (acetate, propionic acid, formic acid, butyric acid, glycolic acid, pyruvate, tartaric acid, phthalic acid, methanesulfonic acid, valeric acid, maleic acid, oxalic acid, chlorate and citric acid) and 0.01 to 5.0 mg l-1 inorganic anions (fluoride, chloride, nitrite, nitrate, bromide, sulfate and phosphate), without extensive sample pretreatment and with an analysis time of only 24 minutes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is not well established whether cytokine production differs in response to different clinical forms of visceral leishmaniasis (VL). In this work, we performed a cross-sectional study to investigate the plasma levels of cytokines [interferon (IFN)-γ, tumour necrosis factor (TNF)-α, interleukin (IL)-2, IL-4, IL-10 and IL-12] involved in the pathogenesis of VL in 80 subjects from VL endemic areas, including subjects with active VL, subjects with asymptomatic infection, subjects with cured VL and uninfected controls. The patients were recruited by sampling from a referral hospital and by random selection from a population-based cohort study. The results showed significant differences in the plasma concentration of all cytokines between the groups (p < 0.05). Patients with the active disease had higher plasma levels of IL-10, IL-4, INF-γ and TNF-α relative to the other groups and they produced more IL-12 than asymptomatic and cured subjects. Only the IL-2 concentration was higher in the asymptomatic and cured subjects relative to the patients with active disease (p < 0.05). Our results suggest that these cytokines can be used as markers in epidemiological studies conducted in endemic areas to distinguish between different clinical forms of VL. However, their usefulness should be confirmed in investigations conducted in other endemic areas.