4 resultados para Calculated from electrical resistivity measurements

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Mg-vacancy binding free enthalpy of Al-Cr solid solution alloys with Mg addition was calculated by electrical resistivity measurements. The obtained value is lower than that obtained for dilute Al-Mg alloys with almost the same Mg content and may be attributed to the diffusion of Mg.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infinity readings for first order kinetics can be calculated from any three measurements (triads) of a physical property l at three equallyspaced times. Accurate results can be obtained from time intervals aslow as 0.4 half-life. Calculation of infinity readings l¥ from severaltriads at increasing values of time gives an insight into the deviation of the first order kinetics when parallel, consecutive or other spurious reactions occur along with the main first order reaction, not allowing direct measurements or calculation of l¥. The proposed method is more sensitive in distinguishing between first and second order kinetics than the Guggenheim and Kezdy-Swinbourne methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The disparity found in the molecular structures of compounds isolated from nine plants of the Swartzia genus indicates that the Swartzia species that furnished cassane diterpenoids and triterpenoidal saponins are more recent, since these metabolites have adopted the mevalonic acid route of formation, abandoning the shikimic acid/acetate route that produces the isoflavonoids found in the remaining species. Chemical indexes calculated from the molecular structure diversities of sixteen 8,11,13-trien-abietane diterpenoids isolated from Swartzia langsdorffii and S. arborescens indicate that S. arborescens is more recent than S. langsdorffii. The results suggest a more evolved position in Swartzia species of the section Possira.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.