27 resultados para COUPLED-WAVE ANALYSIS
em Scielo Saúde Pública - SP
Resumo:
OBJECTIVE To analyze the factors associated with stiffness of the great arteries in prepubertal children.METHODS This study with convenience sample of 231 schoolchildren aged 9-10 years enrolled in public and private schools in Vitória, ES, Southeastern Brazil, in 2010-2011. Anthropometric and hemodynamic data, blood pressure, and pulse wave velocity in the carotid-femoral segment were obtained. Data on current and previous health conditions were obtained by questionnaire and notes on the child’s health card. Multiple linear regression was applied to identify the partial and total contribution of the factors in determining the pulse wave velocity values.RESULTS Among the students, 50.2% were female and 55.4% were 10 years old. Among those classified in the last tertile of pulse wave velocity, 60.0% were overweight, with higher mean blood pressure, waist circumference, and waist-to-height ratio. Birth weight was not associated with pulse wave velocity. After multiple linear regression analysis, body mass index (BMI) and diastolic blood pressure remained in the model.CONCLUSIONS BMI was the most important factor in determining arterial stiffness in children aged 9-10 years.
Resumo:
Background: Changes in the properties of large arteries correlate with higher cardiovascular risk. Recent guidelines have included the assessment of those properties to detect subclinical disease. Establishing reference values for the assessment methods as well as determinants of the arterial parameters and their correlations in healthy individuals is important to stratify patients. Objective: To assess, in healthy adults, the distribution of the values of pulse wave velocity, diameter, intima-media thickness and relative distensibility of the carotid artery, in addition to assessing the demographic and clinical determinants of those parameters and their correlations. Methods: This study evaluated 210 individuals (54% women; mean age, 44 ± 13 years) with no evidence of cardiovascular disease. The carotid-femoral pulse wave velocity was measured with a Complior® device. The functional and structural properties of the carotid artery were assessed by using radiofrequency ultrasound. Results: The means of the following parameters were: pulse wave velocity, 8.7 ± 1.5 m/s; diameter, 6,707.9 ± 861.6 μm; intima-media thickness, 601 ± 131 μm; relative distensibility, 5.3 ± 2.1%. No significant difference related to sex or ethnicity was observed. On multiple linear logistic regression, the factors independently related to the vascular parameters were: pulse wave velocity, to age (p < 0.01) and triglycerides (p = 0.02); intima-media thickness, to age (p < 0.01); diameter, to creatinine (p = 0.03) and age (p = 0.02); relative distensibility, to age (p < 0.01) and systolic and diastolic blood pressures (p = 0.02 and p = 0.01, respectively). Pulse wave velocity showed a positive correlation with intima media thickness (p < 0.01) and with relative distensibility (p < 0.01), while diameter showed a positive correlation with distensibility (p = 0.03). Conclusion: In healthy individuals, age was the major factor related to aortic stiffness, while age and diastolic blood pressure related to the carotid functional measure. The carotid artery structure was directly related to aortic stiffness, which was inversely related to the carotid artery functional property.
Resumo:
In routine studies of sensory nerve conduction, only fibers e7 µm in diameter are analyzed. The late components which originate from thinner fibers are not detected. This explains why a normal sensory action potential (SAP) may be recorded in patients with peripheral neuropathies and sensory loss. In the present study we investigated the late component of the median SAP with a near nerve needle electrode technique in 14 normal volunteers (7 men and 7 women), aged 34.5 ± 14.8 years. The stimulus consisted of rectangular pulses of 0.2-ms duration at a frequency of 1 Hz with an intensity at least 6 times greater than the threshold value for the main component. Five hundred to 2000 sweep averagings were performed. The duration of analysis was 40 or 50 ms and the wave analysis frequency was 200 (-6 dB/oct) to 3000 Hz (-12 dB/oct). We used an apparatus with a two-channel amplifier system, 200 MW or more of entry impedance and a noise level of 0.7 µVrms or less. The main component mean amplitude, conduction velocity and latency and the late component mean amplitude, conduction velocity and latency were respectively (mean ± SD): 26.5 ± 5.42 µV, 56.8 ± 5.42 m/s, 3.01 ± 0.31 ms, 0.12 ± 0.04 µV, 16.4 ± 2.95 m/s and 10.6 ± 2.48 ms. More sophisticated equipment has an internal noise of 0.6 µVrms. These data demonstrate that the technique can now be employed to study thin fiber neuropathies, like in leprosy, using commercial electromyographs, even in non-academic practices
Resumo:
By coupling the Boundary Element Method (BEM) and the Finite Element Method (FEM) an algorithm that combines the advantages of both numerical processes is developed. The main aim of the work concerns the time domain analysis of general three-dimensional wave propagation problems in elastic media. In addition, mathematical and numerical aspects of the related BE-, FE- and BE/FE-formulations are discussed. The coupling algorithm allows investigations of elastodynamic problems with a BE- and a FE-subdomain. In order to observe the performance of the coupling algorithm two problems are solved and their results compared to other numerical solutions.
Resumo:
A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.
Resumo:
A photometric procedure was developed for determination of aflatoxin B1 in peanuts by TLC-CCD technique. The quantification and detection limit were 1.2 μg kg-1 and 0.4 ng per spot, respectively, with mean recovery of 98%. The CCD camera is sufficiently sensitive to detect small changes in spots fluorescence intensity and the results for performance confirmed the efficiency of the method. Another important property of CCD detector is its linearity for a wide range of luminous stimulus determined by analysis of five-point calibration curves using the intensity of AFB1 fluorescence versus AFB1 concentration (0.8 to 4.8 ng per spot). The method was applied to the analysis of thirty nine peanut samples and aflatoxin B1 levels ranged from 16 to 115 μg kg-1. The TLC-CCD and the photometric procedure developed in this study demonstrated to be a simple and efficient tool for quantitative analyses of AFB1 in peanut samples.
Resumo:
Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry was used for the identification of forty doping agents. The improvement in the specificity was remarkable, allowing the resolution of analytes that could not be done by one-dimensional chromatographic systems. The sensitivity observed for different classes of prohibited substances was clearly below the value required by the World Anti-Doping Agency. In addition time-of-flight mass spectrometry gives full spectrum for all analytes without any interference from the matrix, resulting in selectivity improvements. These results could support the implementation of an exhaustive monitoring approach for hundreds of doping agents in a single injection.
Resumo:
Abstract The present work describes setting up a laboratory unit for supercritical fluid extraction. In addition to its construction, a survey of cost was done to compare the cost of the homemade unit with that of commercial units. The equipment was validated using an extraction of annatto seeds’ oil, and the extraction and fractionation of fennel oil were used to validate the two separators; for both systems, the solvent was carbon dioxide. The chemical profiles of annatto and fennel extracts were assessed using thin layer chromatography; the images of the chromatographic plates were processed using the free ImageJ software. The cost survey showed that the homemade equipment has a very low cost (~US$ 16,000) compared to commercial equipment. The extraction curves of annatto were similar to those obtained in the literature (yield of 3.8% oil). The separators were validated, producing both a 2.5% fraction of fennel seed extract rich in essential oils and another extract fraction composed mainly of oleoresins. The ImageJ software proved to be a low-cost tool for obtaining an initial evaluation of the chemical profile of the extracts.
Resumo:
In the present study, the performance of Immunomagnetic Separation technique, coupled with Immunofluorescence (IMS-IFA), was compared with the FAUST et al. and Lutz parasitological techniques for the detection of Giardia lamblia cysts in human feces. One hundred and twenty-seven samples were evaluated by the three techniques at the same time showing a rate of cyst detection of 27.5% by IMS-IFA and 15.7% by both Faust et al. and Lutz techniques. Data analysis showed a higher sensitivity of IMS-IFA for the detection of G. lamblia cysts in comparison with the techniques of FAUST et al. and Lutz. The use of this methodology as a routine procedure enables the processing of many samples simultaneously, in order to increase recovery rate of G. lamblia cysts and reduce the time of sample storage.
Resumo:
Introduction The aim of this study was to explore the environment of Echinococcus granulosus (E. granulosus) protoscolices and their relationship with their host. Methods Proteins from the hydatid-cyst fluid (HCF) from E. granulosus were identified by proteomics. An inductively coupled plasma atomic emission spectrometer (ICP-AES) was used to determine the elements, an automatic biochemical analyzer was used to detect the types and levels of biochemical indices, and an automatic amino acid analyzer was used to detect the types and levels of amino acids in the E. granulosus HCF. Results I) Approximately 30 protein spots and 21 peptide mass fingerprints (PMF) were acquired in the two-dimensional gel electrophoresis (2-DE) pattern of hydatid fluid; II) We detected 10 chemical elements in the cyst fluid, including sodium, potassium, calcium, magnesium, copper, and zinc; III) We measured 19 biochemical metabolites in the cyst fluid, and the amount of most of these metabolites was lower than that in normal human serum; IV) We detected 17 free amino acids and measured some of these, including alanine, glycine, and valine. Conclusions We identified and measured many chemical components of the cyst fluid, providing a theoretical basis for developing new drugs to prevent and treat hydatid disease by inhibiting or blocking nutrition, metabolism, and other functions of the pathogen.
Resumo:
OBJECTIVE: Growing evidence suggests that sudden death after an acute myocardial infarction (AMI) correlates with autonomic nervous system imbalance. Parasympathomimetic drugs have been tested to reverse these changes. However, their effects on ventricular function need specific evaluation. Our objective was to analyze pyridostigmine's (PYR) effect on hemodynamic and echocardiographic variables of ventricular function. METHODS: Twenty healthy volunteers underwent Doppler echocardiographic evaluations, blood pressure (BP), and heart rate (HR) assessment at rest, before and 120 min after ingestion of 30 mg PYR or placebo, according to a double-blind, placebo-controlled, crossed and randomized protocol, on different days. RESULTS: PYR was well tolerated and did not cause alterations in BP or in ventricular systolic function. A reduction in HR of 10.9±1.3% occurred (p<0,00001). There was an A wave reduction in the mitral flow (p<0.01) and an E/A ratio increase (p<0.001) without changes in the other diastolic function parameters (p>0.05). CONCLUSION: PYR reduces HR and increases E/A ratio, without hemodynamic impairment or ventricular function change.
Resumo:
OBJECTIVE - To determine if the application of a continuous electrode paste band on precordial leads results in alteration of the electrocardiographic tracing as compared with an adequate amount of electrode paste, and if the former condition does not cause uniform morphologies from V1 to V6. METHODS - The amplitude and morphology of the electrocardiographic waves on the precordial leads in electrocardiographic tracings, which were performed with standard (control group) or excessive (continuous band) application of the electrode paste, were compared. RESULTS - None of the 106 patients studied showed uniformity of the QRS morphology from V1 to V6. The eletrocardiographic alterations identified in the tracings performed with a continuous electrode paste band that showed statistical significance in relation to the control group were the following: inversion of the P wave in V1; inversion of the T wave in V1, V2, and V3; appearance of R' waves in V1 and V2; disappearance of S waves in V1; appearance of S waves in V5 and V6; alterations in the amplitude of almost all waves, in all leads. CONCLUSION - Application of a continuous electrode paste band in the precordial leads may cause significant alterations in the electrocardiographic tracing obtained.
Resumo:
OBJECTIVE: Using P-wave signal-averaged electrocardiography, we assessed the patterns of atrial electrical activation in patients with idiopathic atrial fibrillation as compared with patterns in patients with atrial fibrillation associated with structural heart disease. METHODS: Eighty patients with recurrent paroxysmal atrial fibrillation were divided into 3 groups as follows: group I - 40 patients with atrial fibrillation associated with non-rheumatic heart disease; group II - 25 patients with rheumatic atrial fibrillation; and group III - 15 patients with idiopathic atrial fibrillation. All patients underwent P-wave signal-averaged electrocardiography for frequency-domain analysis using spectrotemporal mapping and statistical techniques for detecting and quantifying intraatrial conduction disturbances. RESULTS: We observed an important fragmentation in atrial electrical conduction in 27% of the patients in group I, 64% of the patients in group II, and 67% of the patients in group III (p=0.003). CONCLUSION: Idiopathic atrial fibrillation has important intraatrial conduction disturbances. These alterations are similar to those observed in individuals with rheumatic atrial fibrillation, suggesting the existence of some degree of structural involvement of the atrial myocardium that cannot be detected with conventional electrocardiography and echocardiography.
Resumo:
The main purpose of this work is the identification and quantification of phenolic compounds in coal tar samples from a ceramics factory in Cocal (SC), Brazil. The samples were subjected to preparative scale liquid chromatography, using Amberlyst A-27TM ion-exchange resin as stationary phase. The fractions obtained were classified as "acids" and "BN" (bases and neutrals). The identification and quantification of phenols, in the acid fraction, was made by gas chromatography coupled to mass spectrometry (GC/MS). Nearly twenty-five phenols were identified in the samples and nine of them were also quantified. The results showed that coal tar has large quantities of phenolic compounds of industrial interest.
Resumo:
The hydroalcoholic extracts prepared from standard leaves of Maytenus ilicifolia and commercial samples of espinheira-santa were evaluated qualitatively (fingerprinting) and quantitatively. In this paper, fingerprinting chromatogram coupled with Principal Component Analysis (PCA) is described for the metabolomic analysis of standard and commercial espinheira-santa samples. The epicatechin standard was used as an external standard for the development and validation of a quantitative method for the analysis in herbal medicines using a photo diode array detector. This method has been applied for quantification of epicatechin in commercialized herbal medicines sold as espinheira-santa in Brazil and in the standard sample of M. ilicifolia.