62 resultados para COMPARISON WITH QCD

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Serum samples from 356 HBsAg positive asymptomatic carriers, which were titrated by reverse passive hemagglutination, were analysed for the presence of HBV-DNA, HBsAg and IgM anti-HBc. The samples were divided in three classes, according to the titers of HBsAg and IgM anti-HBc and the distribution of HBV-DNA and HBsAg among these classes was studied. In the high titer class of HBsAg, 65% of samples have one or both markers against only 19% in the low titer class. From the total of 356 samples, 121 gave positive results for IgM anti-HBc (33.9%). From these, 38.9% of HBV-DNA and 47.9% of HBeAg were observed, whereas in samples with absence of IgM anti-HBc, 18.3% and 16.6% were respectively found. A higher frequency of agreement between all these markers was found in the class of high titers of HBsAg; however, HBV-DNA was detected in the low titer class of HBsAg and little or no IgM anti-HBc, showing potential blood infectivity even in HBsAg positive borderline samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Screening blood donations for anti-HCV antibodies and alanine aminotransferase (ALT) serum levels generally prevents the transmission of hepatitis C virus (HCV) by transfusion. The aim of the present study was to evaluate the efficiency of the enzyme immunoassay (EIA) screening policy in identifying potentially infectious blood donors capable to transmit hepatitis C through blood transfusion. We have used a reverse transcriptase (RT)-nested polymerase chain reaction (PCR) to investigate the presence of HCV-RNA in blood donors. The prevalence of HCV-RNA positive individuals was compared with the recombinant immunoblot assay (RIBA-2) results in order to assess the usefulness of both tests as confirmatory assays. Both tests results were also compared with the EIA-2 OD/C ratio (optical densities of the samples divided by the cut off value). ALT results were expressed as the ALT quotient (qALT), calculated dividing the ALT value of the samples by the maximum normal value (53UI/l) for the method. Donors (n=178) were divided into five groups according to their EIA anti-HCV status and qALT: group A (EIA > or = 3, ALT<1), group B (EIA > or = 3, ALT>1), group C (1<=EIA<3, ALT<1), group D (1<=EIA<3, ALT>1) and group E (EIA<=0.7). HCV sequences were detected by RT-nested PCR, using primers for the most conserved region of viral genome. RIBA-2 was applied to the same samples. In group A (n=6), all samples were positive by RT-nested PCR and RIBA-2. Among 124 samples in group B, 120 (96.8%) were RIBA-2 positive and 4 (3.2%) were RIBA-2 indeterminate but were seropositive for antigen c22.3. In group B, 109 (87.9%) of the RIBA-2 positive samples were also RT-nested PCR positive, as well as were all RIBA-2 indeterminate samples. In group C, all samples (n=9) were RT-nested PCR negative: 4 (44.4%) were also RIBA-2 negative, 4 (44.4%) were RIBA-2 positive and 1 (11.1%) was RIBA-2 indeterminate. HCV-RNA was detected by RT-nested PCR in 3 (37.5%) out of 8 samples in group D. Only one of them was also RIBA-2 positive, all the others were RIBA-2 indeterminate. All of the group E samples (controls) were RT- nested PCR and RIBA-2 negative. Our study suggests a strong relation between anti-HCV EIA-2 ratio > or = 3 and detectable HCV-RNA by RT-nested PCR. We have also noted that blood donors with RIBA-2 indeterminate presented a high degree of detectable HCV-RNA using RT-nested PCR (75%), especially when the c22.3 band was detected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess safety and efficacy of coronary angioplasty with stent implantation in unstable coronary syndromes. METHODS: Retrospective analysis of in-hospital and late evolution of 74 patients with unstable coronary syndromes (unstable angina or infarction without elevation of the ST segment) undergoing coronary angioplasty with stent placement. These 74 patients were compared with 31 patients with stable coronary syndromes (stable angina or stable silent ischemia) undergoing the same procedure. RESULTS: No death and no need for revascularization of the culprit artery occurred in the in-hospital phase. The incidences of acute non-Q-wave myocardial infarction were 1.4% and 3.2% (p=0.6) in the unstable and stable coronary syndrome groups, respectively. In the late follow-up (11.2±7.5 months), the incidences of these events combined were 5.7% in the unstable coronary syndrome group and 6.9% (p=0.8) in the stable coronary syndrome group. In the multivariate analysis, the only variable with a tendency to significance as an event predictor was diabetes mellitus (p=0.07; OR=5.2; 95% CI=0.9-29.9). CONCLUSION: The in-hospital and late evolutions of patients with unstable coronary syndrome undergoing angioplasty with intracoronary stent implantation are similar to those of the stable coronary syndrome group, suggesting that this procedure is safe and efficacious when performed in unstable coronary syndrome patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AbstractBackground:Risk scores for cardiac surgery cannot continue to be neglected.Objective:To assess the performance of “Age, Creatinine and Ejection Fraction Score” (ACEF Score) to predict mortality in patients submitted to elective coronary artery bypass graft and/or heart valve surgery, and to compare it to other scores.Methods:A prospective cohort study was carried out with the database of a Brazilian tertiary care center. A total of 2,565 patients submitted to elective surgeries between May 2007 and July 2009 were assessed. For a more detailed analysis, the ACEF Score performance was compared to the InsCor’s and EuroSCORE’s performance through correlation, calibration and discrimination tests.Results:Patients were stratified into mild, moderate and severe for all models. Calibration was inadequate for ACEF Score (p = 0.046) and adequate for InsCor (p = 0.460) and EuroSCORE (p = 0.750). As for discrimination, the area under the ROC curve was questionable for the ACEF Score (0.625) and adequate for InsCor (0.744) and EuroSCORE (0.763).Conclusion:Although simple to use and practical, the ACEF Score, unlike InsCor and EuroSCORE, was not accurate for predicting mortality in patients submitted to elective coronary artery bypass graft and/or heart valve surgery in a Brazilian tertiary care center. (Arq Bras Cardiol. 2015; [online].ahead print, PP.0-0)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Immunofluorescence and immunoperoxidase test directed against early viral antigens, and DNA-DNA hybridization were compared with viral isolation for their abilities to detect Cytomegalovirus (CVM) in the urine of 89 HIV infected patients. From the 100 urine samples collected, 70 were found positive by at least one method. Considering viral isolation as the "gold standard" technique, immunofluorescence and immunoperoxidase had a sensitivity of 92.3% and88% respectively, with a specificity in both cases of 95%. DNA-DNA hybridization showed a sensitivity of 90% but with lower (60%) specificity. All of the three assays were effective in detecting CVM from urine and the technical advantage of each is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Four virus clones were derived from the Edmonston strain of measles virus by repeated plaque purification. These clones were compared with the vaccine strains Schwarz and CAM-70 in terms of biological activities including plaque formation, hemagglutination, hemolysis and replication in Vero cells and chick embryo fibroblasts (CEF). Two clones of intermediate plaque yielded mixed plaque populations on subcultivation whereas the other two, showing small and large plaque sizes, showed stable plaque phenotypes. The vaccine strains showed consistent homogeneous plaque populations. All the Edmonston clones showed agglutination of monkey erythrocytes in isotonic solution while both vaccine strains hemagglutinated only in the presence of high salt concentrations. Variation in the hemolytic activity was observed among the four clones but no hemolytic activity was detected for the vaccine virus strains. Vaccine strains replicated efficiently both in Vero cells and CEF. All four clones showed efficient replication in Vero cells but different replication profiles in CEF. Two of them replicated efficiently, one was of intermediate efficiency and the other showed no replication in CEF. Two of the clones showed characteristics similar to vaccine strains. One in terms of size and homogeneity of plaques, the other for a low hemolytic activity and both for the efficiency of propagation in CEF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, HIV-1 viral load quantitation determined by Nucleic Acid Sequence Based Amplification (NASBA) was compared with other surrogate disease progression markers (antigen p24, CD4/CD8 cell counts and b-2 microglobulin) in 540 patients followed up at São Paulo, SP, Brazil. HIV-1 RNA detection was statistically associated with the presence of antigen p24, but the viral RNA was also detected in 68% of the antigen p24 negative samples, confirming that NASBA is much more sensitive than the determination of antigen p24. Regarding other surrogate markers, no statistically significant association with the detection of viral RNA was found. The reproducibility of this viral load assay was assessed by 14 runs of the same sample, using different reagents batches. Viral load values in this sample ranged from 5.83 to 6.27 log (CV = 36 %), less than the range (0.5 log) established to the determination of significant viral load changes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The terrestrial immature stages of the Chilean horse fly, Protodasyapha (Protodasyapha) hirtuosa (Philippi), are described. P.(P.) hirtuosa resembles Ectenopsis vulpecula Macquart and Caenoprosopon trichocera (Bigot) from Australia, and Esenbeckia delta Hine from North America, in both the larval and pupal stages. Some characters that are shared between these species are unique and provide evidence of their monophyletic origin. Larvae of P. hirtuosa were found 3-5 below of the soil surface and associated with larvae of Coleoptera, Lepidoptera and Diptera.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since 1984, DNA tests based on the highly repeated subtelomeric sequences of Plasmodium falciparum (rep 20) have been frequently used in malaria diagnosis. Rep 20 is very specific for this parasite, and is made of 21 bp units, organized in repeated blocks with direct and inverted orientation. Based in this particular organization, we selected a unique consensus oligonucleotide (pf-21) to drive a PCR reaction coupled to hybridization to non-radioactive labeled probes. The pf-21 unique oligo PCR (pf-21-I) assay produced DNA amplification fingerprints when was applied on purified P. falciparum DNA samples (Brazil and Colombia), as well as in patient's blood samples from a large area of Venezuela. The performance of the Pf-21-I assay was compared against Giemsa stained thick blood smears from samples collected at a malaria endemic area of the Bolívar State, Venezuela, at the field station of Malariología in Tumeremo. Coupled to non-radioactive hybridization the pf-21-I performed better than the traditional microscopic method with a r=1.7:1. In the case of mixed infections the r value of P. falciparum detection increased to 2.5:1. The increased diagnostic sensitivity of the test produced with this homologous oligonucleotide could provide an alternative to the epidemiological diagnosis of P. falciparum being currently used in Venezuela endemic areas, where low parasitemia levels and asymptomatic malaria are frequent. In addition, the DNA fingerprint could be tested in molecular population studies

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dot enzyme-linked immunosorbent assay (dot-ELISA) was standardized using excretory-secretory antigens of Toxocara canis for the rapid immunodiagnosis of human toxocariasis. Thirty patients with clinical signs of toxocariasis, 20 cases with other parasitic diseases, and 40 healthy subjects were tested. A total of 0.2 ng of antigen per dot, serum dilution of 1:160 and dilution conjugate of 1:1000 were found optimal. The sensitivity and specificity of the assay were 100 and 95%, respectively. Comparable sensitivity of dot-ELISA and the standard ELISA was obtained, but only 3 cross-reactions occurred in the dot-ELISA, compared with 6 in the standard ELISA. Dot-ELISA is simple to perform, rapid, and low cost. Large-scale screening studies should be done to evaluate its usefulness under field conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eimeria jirkamoraveci sp. n. is described from faeces of two specimens of the toad-headed, side-necked turtle Batrachemys heliostemma collected at Iquitos in Peru. Oocysts are ovoid to almost spherical, 10.6 (8-12) × 8.9 (7-10) mum, without micropyle, polar granule and oocyst residuum. One conically stretched end and three blunt conical tubercles at the opposite end of oocyst give it mitra-like appearance. Sporocysts are elongated, ellipsoidal, 7.2 (6-8) × 4.1 (4-4.5) mum, with a small, knob-like Stieda body and sporocyst residuum composed of fine granules. To avoid possible conspecificity, the described new species is thoroughly compared with the most similar coccidium, E. mitraria, collected from its type host, Chinemys reevesii.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study describes the genetic relationships of the first human astrovirus type-8 (HAstV-8) detected in Belém-Brazil, during a public hospital-based study. This strain was compared with other HAstV-8 strains identified elsewhere which have sequences available at GeneBank. The regions ORF1a (primers Mon348/Mon340) and ORF2 (primers Mon269/Mon270) were analyzed by nucleotide sequencing and a high similarity rate was observed among the Belém strain and other HAstV-8 strains. In ORF1a, homology values of 93-100% were detected, and in ORF2 96-99%. Considering the sequence variation (7%) observed in ORF2 region, it was suggested that HAstV-8 strains could be divided in three different lineages.