22 resultados para CATHODIC ELECTROCHEMILUMINESCENCE
em Scielo Saúde Pública - SP
Resumo:
The present study concern on mycologic and immunochemical data obtained from two samples of a fungus considered as belonging to the species Paracoccidioides cerebriformis described by Moore in 1935, and maintained since then on Sabourauds agar in the mycology collection of the Instituto de Medicina Tropical de São Paulo. After 60 years, the samples exhibited the same characteristics described by Moore (1935). However, experimental lesions did not resulted in guinea-pigs inoculated intratesticularly. The dominant antigen in Paracoccidioides brasiliensis, 43 kDa glicoprotein (gp43), could not be demonstrated by SDS PAGE and Western blotting. Immunoelectrophoresis did not demonstrated the E arch of cathodic migration using a policlonal anti gp43 serum. According to these findings, it is concluded that the fungus described by Moore (1935) as P. cerebriformis does not belong to the genus Paracoccidioides. Paracoccidioidomycosis should therefore be considered as resulting from infection by a single species, Paracoccidioides brasiliensis (Splendore, 1912) as asserted by Almeida (1930). Further studies, through molecular biology methods, could identify the mentioned fungus
Resumo:
With the aim to evaluate the circulating cathodic antigen (CCA) levels in relation to the different clinical phases of Schistosoma sp. infection a sandwich ELISA using monoclonal antibody 5H11 was performed. The sera of three groups of 25 Brazilian patients with acute, intestinal and hepatosplenic forms of S. mansoni infection were tested and compared to a non-infected control group. Patients and control groups were matched for age and sex and the number of eggs per gram of feces was equally distributed among the three patient groups. Sensitivity of 100%, 72%, 52% of the assay was observed for the intestinal, hepatosplenic and acute toxemic groups respectively. The specificity was 100%. Intestinal and hepatosplenic groups presented CCA levels significantly higher in comparison to those observed for acute patients (F-ratio = 2,524; p = 0.000 and F-ratio = 6,314; p = 0.015 respectively). There was no significant difference of CCA serum levels between hepatosplenic and intestinal groups (F-ratio = 1,026; p = 0.316).
Resumo:
Single-stranded DNA (ssDNA) is a prerequisite for electrochemical sensor-based detection of parasite DNA and other diagnostic applications. To achieve this detection, an asymmetric polymerase chain reaction method was optimised. This method facilitates amplification of ssDNA from the human lymphatic filarial parasite Wuchereria bancrofti. This procedure produced ssDNA fragments of 188 bp in a single step when primer pairs (forward and reverse) were used at a 100:1 molar ratio in the presence of double-stranded template DNA. The ssDNA thus produced was suitable for immobilisation as probe onto the surface of an Indium tin oxide electrode and hybridisation in a system for sequence-specific electrochemical detection of W. bancrofti. The hybridisation of the ssDNA probe and target ssDNA led to considerable decreases in both the anodic and the cathodic currents of the system's redox couple compared with the unhybridised DNA and could be detected via cyclic voltammetry. This method is reproducible and avoids many of the difficulties encountered by conventional methods of filarial parasite DNA detection; thus, it has potential in xenomonitoring.
Resumo:
In this paper is presented electrochemical evidences of the influence of the light on the electrochemical behavior of nickel electrode in diluted sulfuric acid. The current densities related with the electrooxidation of the metal decreases when the electrode is under illumination. The corrosion potential, Ecorr , shift to a more positive value in this condition. This effect was observed with polychromatic light and with different wavelength glass filters such as 700 nm and 520 nm. It was observed that increasing the temperature of the solution, the current densities related with cathodic and anodic processes, increases instead of decreases. The activation energy related with the electrooxidation of the electrode was higher under illumination than in the dark. It is suggested that this behavior may be related or with a photo-inhibition effect either with dessorption of adsorbed water involved in the electrooxidation mechanism.
Resumo:
Electrochemical methods applied to organic species transformation has been used as excellent synthesis tools. C-C bonds can be established, making possible polymer synthesis by both anodic and cathodic reactions of suitable monomer species at the working electrode surface. In this study, anodic procedure was used to electropolymerization of 2-mercaptobenzimidazole at reticulated glassy carbon (RGC) surface. 2-mercaptobenzimidazole presents ligand sites towards Hg2+, Ag+ and Cu2+ ions. The obtained material has been able to adsorb the above mentioned ions in aqueous solution.
Resumo:
This paper presents some results that may be used as previous considerations to a hydrogen peroxide electrogeneration process design. A kinetic study of oxygen dissolution in aqueous solution is carried out and rate constants for oxygen dissolution are calculated. Voltammetric experiments on vitreous carbon cathode shown that the low saturation concentration drives the oxygen reduction process to a mass transfer controlled process which exhibits low values of limiting currents. Results have shown that the hydrogen peroxide formation and its decomposition to water are separated by 400 mV on the vitreous carbon surface. Diffusion coefficients for oxygen and hydrogen peroxide are calculated using data taken from Levich and Tafel plots. In a series of bulk electrolysis experiments hydrogen peroxide was electrogenerated at several potential values, and concentration profiles as a function of the electrical charged passed were obtained. Data shown that, since limiting current plateaus are poorly defined onto reticulated vitreous carbon, cathodic efficiency may be a good criterion for choosing the potential value in which hydrogen peroxide electrogeneration should be carried out.
Resumo:
In this work, cathodes employed in secondary lithium batteries are reviewed. These cathodes have great technologic and scientific importance, specifically, materials for cathodes as electronic conductor polymers (ECP), transition metal oxides (TMO) and nanocomposites of ECP/TMO. The use of a specific cathodic material is based in some intrinsic characteristics that improve the performance of the battery. Thus, some vantages and disvantages of these insertion compounds are discussed, as lithium insertion capacity, energy density, and the ciclability of these materials.
Resumo:
Probably one of the most difficult and challenging aspects of measuring trace metals in natural waters is to avoid contamination during sampling, manipulation and analysis. This work discusses how to avoid contamination using simple procedures, and considers alternative methods to purify deionised water and low grade reagents to enable accurate determination of trace metals in natural waters in a common laboratory. Measurements were performed by cathodic stripping voltammetry and copper was used as a model metal to test the procedures. It was possible to evaluate copper speciation in natural waters even when total dissolved copper concentration was as low as 1.5 nmol L-1. The methods' accuracy was confirmed by analysis of certified seawater.
Resumo:
The optimization of ferrate(VI) ion generation has been studied due to its favorable characteristics for application in several fields, including environmental quality control. The paper presents the best conditions for electrolytic generation of ferrate(VI) in alkaline media. An appropriate electrolyte was NaOH, 10 mol/L. Circulation of the electrolyte solution was important to avoid acidification close to the anode surface. An anode pre-cleaning with 10% HCl was more efficient than a cathodic pre-polarization. Among the distinct anode materials tested, pig iron showed the best performance, allowing up to 20 g/L of Na2FeO4, in 10 mol/L NaOH solution to be obtained, after 7 h of reactor operation, which is a concentration higher than those found in literature for alternative processes.
Resumo:
This paper provides a review on voltammetric and polarographic methods for the speciation analysis of inorganic and organic arsenic compounds in different matrices. A discussion on the main advantages of electroanalytical methods in comparison with other analytical methods employed for arsenic speciation is presented. The mechanistic aspects of the most relevant techniques employing cathodic and anodic stripping voltammetry as well as polarographic methods published in the last twenty five years are summarized and discussed. The bibliographic references cited in this work were selected from the Web of Science (published by the ISI) and the main journals of analytical chemistry.
Resumo:
Procion Green HE-4BD is a reactive dye currently used in affinity purification, and commonly present as a contaminant in the final biological preparation. An assay method is described to determine trace amounts of the dye in the presence of human serum albumin(HSA) and leakage from agarose as affinity sorbent by cathodic stripping voltammetry. The proposed method is based on the reductive peak at -0.55V in B-R buffer pH 3 (E=0V and t= 240s), obtained when samples of HSA 2% (m/v) containing dye concentrations in sodium hydroxide pH 12 are submitted to a heating time of 330 min at 80 ºC. Linear calibration curves can be obtained for RG19 dye concentrations from 5x10-9 mol L-1 to 8 x10-8 mol L-1. The detection limit (3sigma) is 1x10-9 mol L-1.
Resumo:
Fuel cells are attracting much interest as efficient and clean energy conversion devices. The main components of low temperature fuel cells are the electrocatalysts used to promote the anodic and cathodic reactions, which are based on platinum and platinum alloys. These electrocatalysts are normally prepared in the form of metal nanoparticles supported on a conductive material, usually high surface area carbon, to improve catalyst utilization and reduce cost. This work presents and comments some methods used presently to produce these electrocatalysts. The performances of the produced electrocatalysts are compared to that of state-of-the-art commercial E-TEK electrocatalysts.
Resumo:
The aim of this work was to optimize the preparation of electrodes with riboflavin (RF) immobilized on a silica surface modified with niobium oxide and carbon paste. Electrode preparation was optimized employing a factorial design consisting of two levels and three factors. The electrochemical properties of immobilized RF were investigated by cyclic voltammetry. The factorial analysis was carried out analysing the current intensity (Ipa). It was possible to optimize the electrode to get the best reversibility in the redox process, i. e. the lowest separation between anodic and cathodic peak potentials and a current ratio close to unity. The concentration of supporting electrolyte has a small effect. The proportion has the highest effect and the interaction factor between proportion and mixture has also a significant effect on the current intensity.
Resumo:
A boron-doped diamond electrode is used for determination of Mn(II) in atmospheric particulate matter by square wave cathodic stripping voltammetry. The analytical curve was linear for Mn(II) concentrations between 5.0 and 37.5 µg L-1, with quantification limit of 3.6 µg L-1. The precision was evaluated by the relative standard deviation, with values between 5.1% and 9.3%. The electrode is free of adsorption, minimizing memory effects. Samples collected in the workplace atmosphere of a foundry had Mn(II) concentrations between 0.4 and 4 µg m-3. No significant differences were observed between the proposed method and inductively coupled plasma optical emission spectroscopy.
Resumo:
The electrochemical behavior of N-nitrosothiazolidine carboxylic acid (NTAC) on gold and hanging mercury electrodes, using the cyclic and square wave voltammetries, was studied. Whereas NTAC suffer reduction in a single step on the mercury electrode, two peaks appears on the cyclic voltammograms on the gold electrode, one anodic peak overlaying the gold oxide process at 1.2 V and one cathodic peak at -0.41 V vs Ag/AgCl, KCl 3.0 mol L-1. The cathodic peak depends on the previous oxidation of NTAC at the electrode surface, presents irreversible and adsorption controlled characteristics and it is suitable for quantitative purposes.