19 resultados para CATHETERS

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To analyze the results from using endovascular techniques to place long-term chemotherapy catheters when advancing the catheter using the external jugular vein is difficult due to obstructions or kinking. METHODS: Between July 1997 and August 2000, 320 long-term chemotherapy catheters were placed, and in 220 cases the external jugular vein was used as the primary venous approach. In 18 of these patients, correct positioning was not achieved and several endovascular techniques were then utilized to overcome these obstacles, including manipulation of a J-wire with a moveable core, venography, and the exchange wire technique. RESULTS: In 94.5% of the patients with difficulties in obtaining the correct positioning, we were able to advance the long-term catheter to the desired position with the assistance of endovascular techniques. CONCLUSIONS: Venography and endovascular guidance techniques are useful for the placement of long-term catheters in the external jugular vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biofilm production is an important mechanism that allows microbes to escape host defences and antimicrobial therapy. Vancomycin has been used largely for the treatment of methicillin-resistant staphylococcal infections. Here, we determined the minimal inhibitory concentration (MIC) and minimal biofilm eradication concentration (MBEC) for 82 Staphylococcus species isolated from central venous catheters (CVC). Our results showed that the 41 strong and moderate-biofilm-producing isolates presented a higher MBEC/MIC ratio for vancomycin than the 24 weak-biofilm-producing isolates, illustrating the importance of biofilm production ability and the difficulty in treating biofilm-related infections. The MBEC was significantly higher in moderate-biofilm-producing isolates than in weak-biofilm-producing isolates (p < 0.001) and in strong-biofilm-producing isolates than in weak-biofilm-producing isolates (p = 0.001). The correlation between the MIC and the MBEC was poor. Based on our results, we recommend that bacterial biofilms be suspected in all cases of CVC infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract OBJECTIVE Determining which is the most effective solution (heparin flush compared to 0.9% saline flush) for reducing the risk of occlusions in central venous catheters (CVC) in adults. METHOD The systematic review followed the principles proposed by the Cochrane Handbook; critical analysis, extraction and synthesis of data were performed by two independent researchers; statistical analysis was performed using the RevMan program 5.2.8. RESULTS Eight randomized controlled trials and one cohort study were included and the results of the meta-analysis showed no difference (RR=0.68, 95% CI=0.41-1.10; p=0.12). Analysis by subgroups showed that there was no difference in fully deployed CVC (RR=1.09, CI 95%=0.53-2.22;p=0.82); Multi-Lumen CVC showed beneficial effects in the heparin group (RR=0.53, CI 95%=0.29-0.95; p=0.03); in Double-Lumen CVC for hemodialysis (RR=1.18, CI 95%=0.08-17.82;p=0.90) and Peripherally inserted CVC (RR=0.14, CI 95%=0.01-2.60; p=0.19) also showed no difference. CONCLUSION Saline solution is sufficient for maintaining patency of the central venous catheter, preventing the risks associated with heparin administration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to perform a retrospective analysis of cases of candidemia in a Brazilian hospital in the city of Fortaleza, Ceará. A total of 50 blood cultures were analyzed from 40 candidemic patients. The mycological diagnosis was based on the phenotypical analysis and the patients' data were recorded in appropriate files. The most frequent species were Candida parapsilosis (n = 18), followed by C. albicans (n = 14), C. tropicalis (n = 8), C. guillermondii (n = 6), C. glabrata (n = 2), and Candida spp. (n = 2). A detailed descriptive study was undertaken with 21 patients whose medical records were complete. The candidemia episodes occurred in eight male patients and 13 female patients. The most representative risk factors implicated in candidemia were prior antibiotic therapy, central venous catheters, parenteral nutrition, gastric probes and mechanical ventilation. Death occurred in 13 of the 21-candidemic patients. This study demonstrated the emergence of candidemia caused by C. parapsilosis in a Brazilian hospital in the city of Fortaleza, Ceará.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Infections by Candida species are a high-impact problem in public health due to their wide incidence in hospitalized patients. The goal of this study was to evaluate frequency, susceptibility to antifungals, and genetic polymorphism of Candida species isolated from clinical specimens of hospitalized patients. The Candida isolates included in this study were obtained from blood cultures, abdominal fluids, and central venous catheters (CVC) of hospitalized patients at the Clinical Hospital of the Federal University of Uberlândia during the period of July 2010 - June 2011. Susceptibility tests were conducted by the broth microdilution method. The RAPD-PCR tests used employed initiator oligonucleotides OPA09, OPB11, and OPE06. Of the 63 Candida isolates, 18 (28.5%) were C. albicans, 20 (31.7%) were C. parapsilosis complex species, 14 (22.2%) C. tropicalis, four (6.4%) C. glabrata, four (6.4%) C. krusei, two (3.3%) C. kefyr, and one (1.6%) C. lusitaniae. In vitro resistance to amphotericin B was observed in 12.7% of isolates. In vitroresistance to azoles was not detected, except for C. krusei. The two primers, OPA09 and OPB11, were able to distinguish different species. Isolates of C. albicans and C. parapsilosis complex species presented six and five clusters, respectively, with the OPA09 marker by RAPD-PCR, showing the genetic variability of the isolates of those species. It was concluded that members of the C. parapsilosis complex were the most frequent species found, and most isolates were susceptible to the antifungals amphotericin B, flucozanole, and itraconazole. High genetic polymorphisms were observed for isolates of C. albicans and C. parapsilosis complex species, mainly with the OPA09 marker.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Vascular access in patients undergoing hemodialysis is considered a critical determinant of bloodstream infection (BSI) and is associated with high morbidity and mortality. The purpose of this study was to investigate the occurrence of BSI in patients with end-stage renal disease using central venous catheters for hemodialysis. Methods A cohort study was conducted in a public teaching hospital in central-western Brazil from April 2010 to December 2011. For every patient, we noted the presence of hyperemia/exudation upon catheter insertion, as well as fever, shivering, and chills during hemodialysis. Results Fifty-nine patients were evaluated. Thirty-five (59.3%) patients started dialysis due to urgency, 37 (62.7%) had BSI, and 12 (20%) died. Hyperemia at the catheter insertion site (64.9%) was a significant clinical manifestation in patients with BSI. Statistical analysis revealed 1.7 times more cases of BSI in patients with hypoalbuminemia compared with patients with normal albumin levels. The principal infective agents identified in blood cultures and catheter-tip cultures were Staphylococcus species (24 cases), non-fermentative Gram-negative bacilli (7 cases of Stenotrophomonas maltophilia and 5 cases of Chryseobacterium indologenes), and Candida species (6). Among the Staphylococci identified, 77.7% were methicillin-resistant, coagulase-negative Staphylococci. Of the bacteria isolated, the most resistant were Chryseobacterium indologenes and Acinetobacter baumannii. Conclusions Blood culture was demonstrated to be an important diagnostic test and identified over 50% of positive BSI cases. The high frequency of BSI and the isolation of multiresistant bacteria were disturbing findings. Staphylococcus aureus was the most frequently isolated microorganism, although Gram-negative bacteria predominated overall. These results highlight the importance of infection prevention and control measures in dialysis units.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: We present the results of treatment by laparoscopy of two patients with retroperitoneal fibrosis and review the literature since 1992, when the first case of this disease that was treated using laparoscopy was published. We also discuss the contemporary alternatives of clinical treatment with corticosteroids and tamoxifen. CASE REPORT: Two female patients, one with idiopathic retroperitoneal fibrosis, and other with retroperitoneal fibrosis associated with Riedel's thyroiditis, were treated using laparoscopic surgery. Both cases had bilateral pelvic ureteral obstruction and were treated using the same technique: transperitoneal laparoscopy, medial mobilization of both colons, liberation of both ureters from the fibrosis, and intraperitonealisation of the ureters. Double-J catheters were inserted before the operations and removed 3 weeks after the procedures. The first patient underwent intraperitonealisation of both ureters in a single procedure. The other had 2 different surgical procedures because of technical difficulties during the first operation. Both patients were followed for more than 1 year and recovered completely from the renal insufficiency. One of them still has occasional vague lumbar pain. There were no abnormalities in the intravenous pyelography in either case. CONCLUSIONS: Surgical correction of retroperitoneal fibrosis, when indicated, should be attempted using laparoscopy. If possible, bilateral ureterolysis and intraperitonealisation of both ureters should be performed in the same operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Infection is the leading complication of long-term central venous catheters, and its incidence may vary according to catheter type. The objective of this study was to compare the frequency and probability of infection between two types of long-term intravenous devices. METHODS: Retrospective study in 96 onco-hematology patients with partially implanted catheters (n = 55) or completely implanted ones (n = 42). Demographic data and catheter care were similar in both groups. Infection incidence and infection-free survival were used for the comparison of the two devices. RESULTS: In a median follow-up time of 210 days, the catheter-related infection incidence was 0.2102/100 catheter-days for the partially implanted devices and 0.0045/100 catheter-days for the completely implanted devices; the infection incidence rate was 46.7 (CI 95% = 6.2 to 348.8). The 1-year first infection-free survival ratio was 45% versus 97%, and the 1-year removal due to infection-free survival ratio was 42% versus 97% for partially and totally implanted catheters, respectively (P <.001 for both comparisons). CONCLUSION: In the present study, the infection risk was lower in completely implanted devices than in partially implanted ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVE: With the increased use of intracoronary stents, in-stent restenosis has become a clinically significant drawback in invasive cardiology. We retrospectively assessed the short- and long-term outcomes after excimer laser coronary angioplasty of in-stent restenosis. METHODS: Twenty-five patients with 33 incidents of in-stent restenosis treated with excimer laser coronary angioplasty (ELCA) were analyzed. Sixty-six percent were males, mean age of 73±11 years, and 83% were functional class III-IV (NYHA). ELCA was performed using 23 concentric and 10 eccentric catheters with a diameter of 1.6-2.2 mm, followed by balloon angioplasty (PTCA) and ultrasound monitoring. The procedure was performed in the following vessels: left anterior descending artery, 10; left circumflex artery, 8; right coronary artery, 6; left main coronary artery, 2; and venous bypass graft, 7. RESULTS: The ELCA was successful in 71% of the cases, and PTCA was 100% successful. The diameter of the treated vessels was 3.44±0.5mm; the minimal luminal diameter (MLD) increased from 0.30mm pre-ECLA to 1.97mm post-ELCA, and to 2.94mm post-PTCA (p<0.001). The percent stenosis was reduced from 91.4±9.5% before ECLA to 42.3±14.9% after ELCA and to 14.6 ± 9.3% after PTCA (p<0.001). Seventeen (68%) patients were asymptomatic at 6 months and 15 (60%) at 1 year. New restenosis rates were 8/33 (24.2%) at 6 months and 9 /33 (27.3%) at 12 months. CONCLUSION: ELCA is safe and effective for the treatment of in-stent restenosis. In the present sample, a slight increase in new restenotic lesions between 6 and 12 months was found.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS: We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5±5.5 years. Forty-seven leads were from pacemakers, and 9 were from defibrillators. Thirty-eight leads were in use, 14 had been abandoned in the pacemaker pocket, and 4 had been abandoned inside the venous system. RESULTS: We successfully extracted 54 catheters, obtaining a 96.4% rate of success and an 82.1% rate for complete extraction. The 2 unsuccessful cases were due to the presence of calcium in the trajectory of the lead. The mean duration of laser light application was 123.0±104.5 s, using 5,215.2±4,924.0 pulses, in a total of 24.4±24.2 cycles of application. Thirty-four leads were extracted from the myocardium with countertraction after complete progression of the laser sheath, 12 leads came loose during the progression of the laser sheath, and the remaining 10 were extracted with other maneuvers. One patient experienced cardiac tamponade after extraction of the defibrillator lead, requiring open emergency surgery. CONCLUSION: The use of the excimer laser allowed extraction of the leads with a 96% rate of success; it was not effective in 2 patients who had calcification on the lead. One patient (2.8%) had a complication that required cardiac surgery on an emergency basis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To characterize the cardiac electrophysiologic effects of cocaine. METHODS: In 8 dogs (9-13 kg), electrophysiologic parameters and programmed stimulation were undertaken using transvenous catheters at baseline, and after cocaine intravenous infusion (12 mg/kg bolus followed by 0.22 mg/kg/min for 25 minutes). RESULTS: Cocaine plasma levels (n=5) rose to 6.73± 0.56 mg/mL. Cocaine did not affect sinus cycle length and arterial pressure. Cocaine prolonged P wave duration (54±6 vs 73±4 ms, P<0.001), PR interval (115±17 vs 164±15 ms, P<0.001), QRS duration (62±10 vs 88±14 ms, P<0.001), and QTc interval (344±28 vs 403±62 ms, P=0.03) but not JT interval (193±35 vs 226±53 ms, NS). Cocaine prolonged PA (9±6 vs 23±8 ms, P<0.001), AH (73±16 vs 92±15 ms; P=0.03), and HV (35±5 vs 45±3ms; P<0.001) intervals and Wenckebach point (247±26 vs 280±28 ms, P=0.04). An increase occurred in atrial (138±8 vs 184± 20 ms; P<0.001) and ventricular (160±15 vs 187±25 ms; P=0.03) refractoriness at a cycle length of 300 ms. Atrial arrhythmias were not induced in any dog. Ventricular fibrillation (VF) was induced in 2/8 dogs at baseline and 4/8 dogs after cocaine. CONCLUSION: High doses of cocaine exert significant class I effects and seem to enhance inducibility of VF but not of atrial arrhythmias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundamentos: O implante por cateter de bioprótese valvar aórtica (TAVI) consolidou-se como alternativa para o tratamento de pacientes com estenose aórtica importante de alto risco cirúrgico. Contudo, há poucos dados na literatura com respeito à obstrução coronária que, apesar de rara, trata-se de grave complicação do TAVI. Objetivo: Avaliar, no contexto brasileiro, a presença dessa importante complicação. Métodos: Foram avaliados todos os casos de obstrução coronária incluídos no Registro Brasileiro de TAVI. Foram coletados dados clínicos, do procedimento, do manejo e de evolução intra-hospitalar. Resultados: Entre 418 pacientes consecutivos do registro, ocorreram três casos de obstrução coronária (incidência de 0,72%). Em sua totalidade, os pacientes eram do sexo feminino, sem cirurgia de revascularização miocárdica (CRM) prévia, com idade média de 85 ± 3 anos, EuroSCORE logístico de 15 ± 6% e STS de 9 ± 4%. Todos os casos foram realizados com a válvula balão-expansível Sapien XT. Em um dos pacientes, com dados de tomografia computadorizada pré-procedimento, verificaram-se origem das artérias coronárias baixa e seio de Valsalva estreito. Todos os pacientes apresentaram-se clinicamente com hipotensão importante e mantida, imediatamente após o implante da válvula, e, apesar de angioplastia com implante de stent, todos os pacientes foram a óbito, sendo dois periprocedimento e um durante hospitalização. Conclusão: A obstrução coronária como complicação do TAVI, apesar de rara, é potencialmente fatal, podendo ocorrer mais frequentemente em mulheres e com as próteses expansíveis por balão. Fatores anatômicos podem estar relacionados com sua ocorrência, ressaltando-se a importância de boa avaliação pré-procedimento no sentido de evitar essa grave complicação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During a five-year period, 932 clinical isolates from cancer patients treated in a Brazilian reference centre were identified as corynebacteria; 86% of the cultures came from patients who had been clinically and microbiologically classified as infected and 77.1% of these patients had been hospitalised (71.1% from surgical wards). The adult solid tumour was the most common underlying malignant disease (66.7%). The univariate and multivariate analyses showed that hospitalised patients had a six-fold greater risk (OR = 5.5, 95% CI = 1.15-26.30 p = 0.033) related to 30-day mortality. The predominant species were Corynebacterium amycolatum (44.7%), Corynebacterium minutissimum (18.3%) and Corynebacterium pseudodiphtheriticum (8.5%). The upper urinary tracts, surgical wounds, lower respiratory tracts, ulcerated tumours and indwelling venous catheters were the most frequent sources of C. amycolatum strains. Corynebacterium jeikeium infection occurred primarily in neutropenic patients who have used venous catheters, while infection caused by C. amycolatum and other species emerged mainly in patients with solid tumours.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Candida species are an important cause of bloodstream infections (BSI). To evaluate the epidemiological, clinical and microbiological aspects of two cohorts {1994-1999 [period 1 (P1) ]; 2000-2004 [period 2 (P2) ]} of candidaemic patients, we performed a retrospective analysis from a laboratory-based survey. A total of 388 candidaemias were identified, with an incidence of 0.20/1,000 patient-days and a significant increase in P2 vs. P1 (0.25 vs. 0.15, p = 0.04). Cancer and prior antibiotic use were frequent and Candida albicans was the most prevalent species found (42.4%). Resistance to fluconazole was found in 2.47% of the strains. No differences were observed in the species distribution of Candida during the study periods. In the P2 cohort, there were higher prevalence of elderly individuals, cardiac, pulmonary and liver diseases, renal failure, central venous catheters and antibiotic therapy. In P1, there were higher prevalence of neurological diseases and chemotherapy. The crude mortality was 55.4%. In conclusion, our incidence rates remained high. Furthermore, the distribution pattern of Candida species and the fluconazole resistance profile remained unchanged. Moreover, we found a clear trend of higher prevalence of candidaemia among the elderly and among patients with comorbidities. Finally, it is necessary to discuss strategies for the prevention and control of Candida BSI in Brazil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Corynebacterium striatum is a potentially pathogenic microorganism that causes nosocomial outbreaks. However, little is known about its virulence factors that may contribute to healthcare-associated infections (HAIs). We investigated the biofilm production on abiotic surfaces of multidrug-resistant (MDR) and multidrug-susceptible (MDS) strains of C. striatum of pulsed-field gel electrophoresis types I-MDR, II-MDR, III-MDS and IV-MDS isolated during a nosocomial outbreak in Rio de Janeiro, Brazil. The results showed that C. striatum was able to adhere to hydrophilic and hydrophobic abiotic surfaces. The C. striatum1987/I-MDR strain, predominantly isolated from patients undergoing endotracheal intubation procedures, showed the greatest ability to adhere to all surfaces. C. striatumbound fibrinogen to its surface, which contributed to biofilm formation. Scanning electron microscopy showed the production of mature biofilms on polyurethane catheters by all pulsotypes. In conclusion, biofilm production may contribute to the establishment of HAIs caused by C. striatum.