118 resultados para Balloon catheter

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To report short and midtem follow-up results of balloon aortic valvuloplasty to treat congenital aortic stenosis. METHODS: Seventy-five patients (median age: 8 years) underwent the procedure through the retrograde femoral or carotid route. RESULTS: The procedure was completed in 74 patients (98.6%). The peak-to-peak systolic gradient dropped from 79.6±27.7 to 22.3±17.8 mmHg (P<0.001), the left ventricular systolic pressure dropped from 164±39.1 to 110±24.8 mmHg (P<0.001), and the left ventricular end diastolic pressure dropped from 13.3±5.5 to 8.5±8.3 mmHg (P< 0.01). Four patients (5.3%) died due to the procedure. Aortic regurgitation (AoR) appeared or worsened in 27/71 (38%) patients, and no immediate surgical intervention was required. A mean follow-up of 50±38 months was obtained in 37 patients. Restenosis and significant AoR were observed in 16.6% of the patients. The estimates for being restenosis-free and for having significant AoR in 90 months were 60% and 50%, respectively. CONCLUSION: Aortic valvuloplasty was considered the initial palliative method of choice in managing congenital aortic stenosis, with satisfactory short- and midterm results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To analyze our experience with percutaneous aortic balloon valvuloplasty in newborn infants with aortic stenosis, emphasizing the extraordinary importance of myocardial perfusion.METHODS: Over a 10-year-period, 21 neonates underwent percutaneous aortic balloon valvuloplasty. Age ranged from 2 to 27 days, weight ranged from 2.2 to 4.1 kg and 19 were males. All patients presented with congestive heart failure that could not be treated clinically. The onset of symptoms in the first week of life occurred in 9 patients considered as having critical aortic stenosis. Severe aortic stenosis occurred in 12 patients with the onset of symptoms in the second week of life.RESULTS: Mortality reached 100% in the patients with critical aortic stenosis. The procedure was considered effective in the 12 patients with severe aortic stenosis. Vascular complications included the loss of pulse in 12 patients and rupture of the femoral artery in 2 patients. Cardiac complications included acute aortic regurgitation in 2 patients and myocardial perforation in one. In an 8.2±1.3-year follow-up, 5 of the 12 patients died (2 patients due to septicemia and 3 patients due to congestive heart failure). Five of the other 7 patients underwent a new procedure and 2 required surgery.CONCLUSION: Percutaneous aortic valvuloplasty in neonates is not an effective procedure in the 1st week of life, because at this age the common presentation is cardiogenic shock. It is possible that, in those patients with critical aortic stenosis, dilation of the aortic valve during fetal life may change the prognosis of its clinical outcome.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the efficacy of percutaneous transluminal septal alcoholization in the treatment of refractory obstructive hypertrophic cardiomyopathy (HOC). METHODS: The patients were referred for alcoholization after Doppler echocardiography. Before and after alcoholization, the intraventricular pressure gradient was recorded. Alcoholization was performed with a 3mL injection of absolute alcohol through a coronary angioplasty balloon catheter. The procedure was concluded after a significant reduction or abolition of the pressure gradient. RESULTS: Of 22 patients, 18 (81.8%) successfully concluded the procedure with a reduction in intraventricular pressure gradient at baseline (from 67.6±24.2 mmHg to 3.8± 1.9 mmHg, p<0.005) and after extrasystole (from 110.4± 24.2 mmHg to 9.6±2.6 mm Hg, p<0.005). A significant reduction in mean interventricular septal thickness (from 2± 0.3 mm to 1.7±0.2 mm, p<0.005) and in peak pressure gradient (from 90.7±23.5 mmHg to 6.1±1.4 mmHg, p<0.005) was observed on Doppler echocardiography after 6 months, when all patients were in functional class I. The most frequent acute complication, present in 11% of the patients, was the need for definitive pacing implantation. Relapse of the symptoms and reappearance of the pressure gradient occurred in 16.6% of the patients. One patient (5.5%) died probably due to a diffuse coronary spasm prior to the procedure, and another died suddenly on late follow-up. CONCLUSION: Percutaneous transluminal septal alcoholization is effective and safe in the treatment of HOC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The impact of acute volume imbalances on gastric volume (GV) was studied in anesthetized rats (250-300 g). After cervical and femoral vessel cannulation, a balloon catheter was positioned in the proximal stomach. The opposite end of the catheter was connected to a barostat with an electronic sensor coupled to a plethysmometer. A standard ionic solution was used to fill the balloon (about 3.0 ml) and the communicating vessel system, and to raise the reservoir liquid level 4 cm above the animals' xiphoid appendix. Due to constant barostat pressure, GV values were considered to represent the gastric compliance index. All animals were monitored for 90 min. After a basal interval, they were randomly assigned to normovolemic, hypervolemic, hypovolemic or restored protocols. Data were compared by ANOVA followed by Bonferroni's test. Mean arterial pressure (MAP), central venous pressure (CVP) and GV values did not change in normovolemic animals (N = 5). Hypervolemic animals (N = 12) were transfused at 0.5 ml/min with a suspension of red blood cells in Ringer-lactate solution with albumin (12.5 ml/kg), which reduced GV values by 11.3% (P<0.05). Hypovolemic rats (N = 12) were bled up to 10 ml/kg, a procedure that increased GV values by 15.8% (P<0.05). In the restored group (N = 12), shed blood replacement brought GV values back to basal levels in bled animals (P>0.05). MAP and CVP values increased (P<0.05) after hypervolemia but decreased (P<0.05) with hypovolemia. In conclusion, blood volume level modulates gastric compliance, turning the stomach into an adjustable reservoir, which could be part of the homeostatic process to balance blood volume.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Acute thrombosis can be induced in rabbits by a triggering protocol using Russell's viper venom and histamine given after 8 months of a 1% cholesterol diet and balloon desendothelization. In the present study, we tested the hypothesis that aortic desendothelization performed 4 months before the triggering protocol without a high cholesterol diet is a highly effective and less expensive way of producing arterial atherosclerosis and thrombosis. Nineteen male New Zealand white rabbits on a normal diet were studied. The control group (N = 9) received no intervention during the 4-month observation period, while the other group (N = 10) was submitted to aortic balloon desendothelization using a 4F Fogarty catheter. At the end of this period, all animals were killed 48 h after receiving the first dose of the triggering treatment. Eight of 10 rabbits (80%) in the balloon-trauma group presented platelet-rich arterial thrombosis while none of the animals in the control group had thrombus formation (P<0.01). Thus, this model, using balloon desendothelization without dietary manipulation, induces arterial atherosclerosis and thrombosis and may provide possibilities to test new therapeutic approaches

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mycobacterium tuberculosis was isolated from a central venous catheter in a non-immunosuppressed patient with systemic tuberculosis. This case report represents a very uncommon form of isolation of Mycobacterium tuberculosis. A total improvement was obtained after treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phospholipase and proteinase production and the ability of adhesion to buccal epithelial cells (BEC) of 112 Candida isolates originated from oral cavity of HIV infected patients and from blood and catheter of intensive care unit patients were investigated. The proteinase production was detected by inoculation into bovine serum albumin (BSA) agar and the phospholipase activity was performed using egg yolk emulsion. A yeast suspension of each test strain was incubated with buccal epithelial cells and the number of adherence yeast to epithelial cells was counted. A percentage of 88.1% and 55.9% of Candida albicans and 69.8% and 37.7% of non-albicans Candida isolates produced proteinase and phospholipase, respectively. Non-albicans Candida isolated from catheter were more proteolytic than C. albicans isolates. Blood isolates were more proteolytic than catheter and oral cavity isolates while oral cavity isolates produced more phospholipase than those from blood and catheter. C. albicans isolates from oral cavity and from catheter were more adherent to BEC than non-albicans Candida isolates, but the adhesion was not different among the three sources analyzed. The results indicated differences in the production of phospholipase and proteinase and in the ability of adhesion to BEC among Candida spp. isolates from different sources. This study suggests that the pathogenicity of Candida can be correlated with the infected site.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Catheter-associated bloodstream infection (CA-BSI) is the most common nosocomial infection in neonatal intensive care units. There is evidence that care bundles to reduce CA-BSI are effective in the adult literature. The aim of this study was to reduce CA-BSI in a Brazilian neonatal intensive care unit by means of a care bundle including few strategies or procedures of prevention and control of these infections. METHODS: An intervention designed to reduce CA-BSI with five evidence-based procedures was conducted. RESULTS: A total of sixty-seven (26.7%) CA-BSIs were observed. There were 46 (32%) episodes of culture-proven sepsis in group preintervention (24.1 per 1,000 catheter days [CVC days]). Neonates in the group after implementation of the intervention had 21 (19.6%) episodes of CA-BSI (14.9 per 1,000 CVC days). The incidence of CA-BSI decreased significantly after the intervention from the group preintervention and postintervention (32% to 19.6%, 24.1 per 1,000 CVC days to 14.9 per 1,000 CVC days, p=0.04). In the multiple logistic regression analysis, the use of more than 3 antibiotics and length of stay >8 days were independent risk factors for BSI. CONCLUSIONS: A stepwise introduction of evidence-based intervention and intensive and continuous education of all healthcare workers are effective in reducing CA-BSI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A particular event concerning a Swan-Ganz catheter complication is reported. A 41-year-old woman was admitted at the emergency room of our hospital with massive gastrointestinal bleeding. A total gastrectomy was performed. During the postoperative period in the intensive care unit , the patient maintained hemodynamic instability. Invasive hemodynamic monitoring with a pulmonary artery catheter was then indicated. During the maneuvers to insert the catheter, a true knot formation was identified at the level of the superior vena cava. Several maneuvers by radiological endovascular invasive techniques allowed removal of the catheter. The authors describe the details of this procedure and provide comments regarding the various techniques that were employed in overcoming this event. A comprehensive review of evidence regarding the benefits and risks of pulmonary artery catheterization was performed. The consensus statement regarding the indications, utilization, and management of the pulmonary artery catheterization that were issued by a consensus conference held in 1996 are also discussed in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the hypothesis that a 7-day period of indwelling catheter after radical retropubic prostatectomy is effective and safe without the need of performing cystography. METHODS: In the period from January of 2000 to July of 2002, 73 patients underwent radical retropubic prostatectomy, and these patients were prospectively randomized in 2 groups: Group 1-37 patients who had the urethral catheter removed 7 days after the procedure, and Group 2-36 patients who had the catheter removed 14 days after the surgery. The 2 groups were similar, the surgeons and the technique were the same, and no cystography was performed to evaluate the presence of leaks. RESULTS: Two patients in Group 1 had bleeding and clot retention after having the catheter taken out in the seventh postoperative day and were managed by putting the catheter back in for 7 more days. Two patients in Group 2 developed bladder neck stricture and were treated by bladder neck incision with success. The continence rate was the same, with 2 cases of incontinence in each group. About 2 pads a day were used by the patients with incontinence. The average follow-up was 17.5 months (12-36 months). No urinary fistula, urinoma, or pelvic abscesses developed after catheter removal. Two patients were excluded from the analysis of this series: 1 died with a pulmonary embolus in the third postoperative day, and 1 developed a urinary suprapubic fistula before catheter withdrawal, which was maintained for 16 days. CONCLUSION: Withdrawal of the urethral catheter 7 days after radical retropubic prostatectomy, without performing cystography, has a low rate of short-term complications that are equivalent to withdrawal 14 days after the surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Infection is the leading complication of long-term central venous catheters, and its incidence may vary according to catheter type. The objective of this study was to compare the frequency and probability of infection between two types of long-term intravenous devices. METHODS: Retrospective study in 96 onco-hematology patients with partially implanted catheters (n = 55) or completely implanted ones (n = 42). Demographic data and catheter care were similar in both groups. Infection incidence and infection-free survival were used for the comparison of the two devices. RESULTS: In a median follow-up time of 210 days, the catheter-related infection incidence was 0.2102/100 catheter-days for the partially implanted devices and 0.0045/100 catheter-days for the completely implanted devices; the infection incidence rate was 46.7 (CI 95% = 6.2 to 348.8). The 1-year first infection-free survival ratio was 45% versus 97%, and the 1-year removal due to infection-free survival ratio was 42% versus 97% for partially and totally implanted catheters, respectively (P <.001 for both comparisons). CONCLUSION: In the present study, the infection risk was lower in completely implanted devices than in partially implanted ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraaortic balloon counterpulsation is frequently used in patients experiencing severe ventricular dysfunction following maximal drug therapy. However, even with the improvement of percutaneous insertion techniques, the procedure has always been followed by vascular, infectious, and neurological complications. This article describes a case of paraplegia due to intraaortic balloon counterpulsation in the postoperative period of cardiac surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe here two patients with angiographic diagnosis of intrastent restenosis and regional myocardial ischemia. One stent restenosis was located in a native coronary artery and the other in a vein graft. Both were treated with cutting balloon angioplasty (CBA), inflated at low pressures. Angiographic success was obtained and both patients were discharged in the day after the procedure. Cutting balloon angioplasty using low inflation pressures achieved important luminal gains, in these two cases of intrastent restenosis. Further studies are necessary before the effectiveness of this procedure can be precisely defined.