41 resultados para Autonomous sailboat, 3D printer, Composite, Arduino
em Scielo Saúde Pública - SP
Resumo:
The aim of this study was to evaluate the response to the implantation of synthetic hydroxyapatite 30% (HAP-91®) in different physical states as dermal filler. Eighteen New Zealand rabbits were used, distributed randomly into two equal groups and then divided into three groups according to the postoperative period at 8, 21 and 49 days. One mL of HAP-91®, fluid and viscous, was implanted in the subcutaneous tissue, 1 cm proximal to the cranial crest of the right scapula. The thickness of the skin was measured before and after implantation and for the following 15 days. Pain sensitivity assessment was conducted, assigning the following scores: 0 - when the animal allowed the touch of the implant area and expressed no signs of pain; 1 - when the animal allowed the touch, but pain reaction occurred, like increase of the respiratory rate or attempt to escape; 2 - when the animal did not allow the touch to the implanted area. At 8, 21 and 49 days, biopsy of the implanted area was performed. No difference was observed between the thickness of the skin (p>0.05) and all animals received a score 0 for soreness. Histological analysis did not reveal any obvious inflammatory process, showing a predominance of mononuclear cells in samples of eight days and tissue organization around the biomaterial with a tendency to encapsulation. The results indicate that HAP-91®, both viscous and fluid, is biocompatible and suitable for dermal filling.
Resumo:
FUNDAMENTO: O ecocardiograma tridimensional em tempo real (ECO 3D) e a tomografia computadorizada ultra-rápida (CT) são dois novos métodos de análise da fração de ejeção e dos volumes do VE. OBJETIVO: Comparar as medidas da FEVE e dos volumes do VE aferidos pelo ECO 3D e pela CT ultra-rápida. MÉTODOS: Foram estudados pelo ECO 3D e pela CT ultra-rápida de 64 cortes, 39 pacientes consecutivos (27 homens, média etária de 57±12 anos). Foram analisados: FEVE e volumes do VE. Análise estatística: coeficiente de correlação (r: Pearson), teste de Bland & Altman, teste de regressão linear, 95 % IC, p<0,05. RESULTADOS: Medidas do ECO 3D: a FEVE variou de 56,1 a 78,6 (65,5±5,58)%; volume diastólico final variou de 49,6 a 178,2 (87±27,8)ml; volume sistólico final variou de 11,4 a 78 (33,1±13,6)ml. Medidas da CT: a FEVE variou de 53 a 86 (67,8±7,78)%; volume diastólico final variou de 51 a 186 (106,5±30,3) ml; volume sistólico final variou de 7 a 72 (35,5±13,4)ml. As correlações entre ECO 3D e CT foram: FEVE (r: 0,7888, p<0,0001, 95% IC 0,6301 a 0,8843); volume diastólico final (r: 0,7695, p<0,0001, 95% IC 0,5995 a 0,8730); volume sistólico final (r: 0,8119, p<0,0001, 95% IC 0,6673 a 0,8975). CONCLUSÃO: Nesta série, foi observada boa correlação entre as medidas da FEVE e entre os volumes ventriculares aferidos pelo ECO3D e pela CT ultra-rápida de 64 cortes.
Resumo:
A terapia de ressincronização cardíaca consiste em tratamento promissor para pacientes com insuficiência cardíaca grave, porém cerca de 30% dos pacientes não apresentam melhora clínica com este tratamento. Por outro lado, aproximadamente 10% dos pacientes submetidos a essa terapia podem apresentar hiper resposta, e a ecocardiografia tridimensional pode oferecer uma opção interessante para a seleção e avaliação de tratamento desses pacientes.
Resumo:
FUNDAMENTO: A ecocardiografia consiste em método muito útil para seleção e avaliação de resposta à terapia de ressincronização cardíaca (TRC). O eco 3D já tem seu papel estabelecido na avaliação dos volumes ventriculares e fração de ejeção ventricular esquerda (FEVE) com excelente correlação de resultados quando comparado à RNM. OBJETIVO: Comparar a avaliação dos volumes ventriculares (VDVE, VSVE), FEVE e massa do VE antes e após a TRC pela ecocardiografia bi (Eco 2D) e tridimensional (Eco 3D). MÉTODOS: Foram avaliados 24 pacientes com IC CFIII ou IV (NYHA), ritmo sinusal QRS > 150 ms, em vigência de terapêutica otimizada para IC submetidos a TRC. Foram realizados eletrocardiograma (ECG), avaliação clínica, Eco 2D e 3D antes, três e seis meses após a TRC. A comparação entre as técnicas foi realizada utilizando-se a correlação de Pearson (r). RESULTADOS: No momento basal, a correlação entre os métodos foi de 0,96 para avaliação do VDVE, 0,95 para avaliação do VSVE, 0,87 para FEVE, e 0,72 para massa do VE. Após três meses da TRC, a correlação entre os métodos para análise do VDVE foi de 0,96, 0,95 para VSVE, 0,95 para FEVE, e 0,77 para massa do VE. Após seis meses da TRC, a correlação entre o Eco 2D e 3D para análise do VDVE foi de 0,98, 0,91 para VSVE, 0,96 para FEVE, e 0,85 para massa do VE. CONCLUSÃO: Neste estudo foi observada redução dos VDVE,VSVE, além de melhora da FEVE após a TRC. Houve excelente correlação entre o Eco 2D e o 3D para avaliação dos volumes ventriculares e FEVE, e boa correlação entre os métodos para avaliação da massa ventricular esquerda antes e após a TRC.
Resumo:
FUNDAMENTO: Remodelamento ventricular esquerdo (RVE) após IAM caracteriza fator de mau prognóstico. Há pouca informação na literatura sobre o RVE analisado com ecocardiografia tridimensional (ECO 3D) OBJETIVO: Analisar com ECO 3D as modificações geométricas e volumétricas do ventrículo esquerdo (VE) seis meses após IAM em pacientes submetidos a tratamento primário percutâneo. MÉTODOS: Estudo prospectivo com ECO 3D de 21 indivíduos (16 homens, 56 ± 12 anos), acometidos por IAM com elevação do segmento ST. Foi feita a análise morfofuncional (VE) com ECO 3D (volumes, FEVE, índice de esfericidade 3D) até sete dias e seis meses após o IAM. RVE foi considerado para aumento > 15% do volume diastólico final do VE (VDFVE) após seis meses do IAM, comparado ao VDFVE até sete dias do evento. RESULTADOS: Oito (38%) pacientes apresentaram RVE. Medidas ecocardiográficas (n = 21 pacientes): I- até sete dias do IAM: 1- VDFVE: 92,3 ± 22,3 mL; 2- FEVE: 0,51 ± 0,01; 3- índice de esfericidade: 0,38 ± 0,05; II- após seis meses: 1- VDFVE: 107,3 ± 26,8 mL; 2- FEVE: 0,59 ± 0,01; 3- índice de esfericidade: 0,31 ± 0,05. Coeficiente de correlação (r) entre índice de esfericidade até sete dias do IAM e VDFVE aos seis meses (n = 8) após o IAM: r: 0,74, p = 0,0007; (r) entre índice de esfericidade após seis meses do IAM e VDFVE aos seis meses do IAM: r: 0,85, p < 0,0001. CONCLUSÃO: Nesta série, foi observado RVE em 38% dos pacientes seis meses após IAM. O índice de esfericidade tridimensional foi associado à ocorrência de RVE.
Resumo:
Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.
Incremental Value Of 3D Transesophageal Echocardiography for The Assessment of Mitral Valve Prolapse
Resumo:
D53 (RibomuntyR) is a composite vaccine made of immunogenic ribosomes from 4 bacterial species (Klebsiella pneumoniae, Haemophilus influenzae, Streptococcus pyogenes and Streptococcus pneumoniae) associated with a membrane proteoglycan from a non encapsulated strain of Klebsiella pneumoniae. D53 is a potent inducer of interleukin-1 production by mouse BALB/c spleen cells as shown by the C3H/HeJ thymocyte co-stimulation assay. Furthermore D53 triggers DNA synthesis by mouse spleen cells and induces the maturation of B lymphocytes into immunoglobulin secreting cells. Polyclonal B cell activation by D53 was readily achieved in the C3H/HeJ strain which is deficient in its response to E. coli lipopolysaccharide. The proliferative response to D53 was abrogated by removal of B cells from the spleen cell suspension, but it was not altered after depletion of T cells or adherent cells. D53 induced polyclonal B cell activation of spleen cells from athymic nude mice and from CBA/N mice. Each component of D53 induced polyclona B cell activation except ribosomes from Streptococcus pneumoniae. Each triggered Interleukin-1 synthesis except ribosomes from Klebsiella penumoniae. These in vitro properties may account for some of the in vivo immunostimulating properties of this composite vaccine.
Resumo:
Constantly experiencing limiting situations that hinder a professional practice coherent with its principles - of autonomy and advocacy of users' interests -, and often conditioned to experience moral distress, the nursing profession plays a prominent role in the current health model because it has the characteristic of managing the care rendered to users in a perspective of social inclusion, both in the basic health network and in hospitals. Aiming at carrying out a reflection on the nursing practice and the difficulties present in its work routine, and considering its characteristics as a profession, this article sought to make a reflection between the practice of nursing and the numerous moral challenges imposed by the routine, resulting, in many cases, in a value crisis that can reverberate directly on the quality of the service rendered, and in abandonment of the ideals of advocacy for users.
Resumo:
Este trabalho teve como objetivo indicar algumas possíveis manipulações ecofisiológicas, com base em experimentos de arquitetura de plantas. Plantas de erva-mate, seringueira e videira foram caracterizadas no campo e no laboratório, e suas maquetes 3D foram reconstruídas com os programas V-Plants e PlantGLViewer. Indicações sobre a análise de crescimento e impactos ambientais, com a aplicação de diversas simulações, foram discutidas.
Resumo:
The objective of this work was to build mock-ups of complete yerba mate plants in several stages of development, using the InterpolMate software, and to compute photosynthesis on the interpolated structure. The mock-ups of yerba-mate were first built in the VPlants software for three growth stages. Male and female plants grown in two contrasting environments (monoculture and forest understory) were considered. To model the dynamic 3D architecture of yerba-mate plants during the biennial growth interval between two subsequent prunings, data sets of branch development collected in 38 dates were used. The estimated values obtained from the mock-ups, including leaf photosynthesis and sexual dimorphism, are very close to those observed in the field. However, this similarity was limited to reconstructions that included growth units from original data sets. The modeling of growth dynamics enables the estimation of photosynthesis for the entire yerba mate plant, which is not easily measurable in the field. The InterpolMate software is efficient for building yerba mate mock-ups.