31 resultados para Appellat procedure

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simplified methodology for the quantitative electroelution of proteins from polyacrylamide gels is described. After staining with Coomassie Brilliant Blue R 250, the identified bands are excised from the gel and the proteins eluted using a procedure developed for use in conventional tube gel electrophoresis equipment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo® , an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo® showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo® could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A - rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo® affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supernatant of boiled spleen saline-suspensions of Yersinia pestis experimentally infected animals were used as template for PCR amplification without DNA extraction. PCR sensitivity was enhanced by a second round of amplification (Nested). No amplification was observed from non-infected animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this study is to evaluate the benefits of drainage in the Stoppa procedure for inguinal repair. PATIENTS AND METHODS: The use of a suction drain was randomized at the end of the surgical intervention in 26 male patients undergoing inguinal hernia repair, divided into 2 groups: Group A, 12 patients undergoing drainage, and group B, 14 patients not undergoing drainage. On the second postoperative day, all patients underwent abdominal pelvic computed tomography scan examination to detect the presence of abdominal fluid collection. RESULTS: In group A, no patient developed fluid collection in the preperitoneal space, and 1 patient presented with an abscess in the preperitoneal space on the 15th postoperative day. In group B, 12 patients presented with fluid collections in the preperitoneal space on computed tomography scan evaluation. However, only 3 patients presented minor complications. None of the patients developed a major complication. CONCLUSION: The use of suction drainage with the Stoppa procedure does not provide any benefit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the presence and the prevalence of arrhythmias and the variability of the heart rate in the medium-term postoperative period following the maze procedure for chronic atrial fibrillation (AF). METHODS: Seventeen patients with a mean age of 51.7±12.9 years, who previously underwent the maze procedure without cryoablation for chronic atrial fibrillation, were evaluated with the 24 hour electrocardiogram (ECG) - Holter monitoring from the 6th month after the operation. Valvular and coronary procedures were concomitantly performed. RESULTS: The mean heart rate during Holter monitoring was 82±8bpm; the maximal heart rate was 126 ± 23bpm and the minimal heart rate 57±7bpm. Sinus rhythm was found in 10 (59%) patients and atrial rhythm was found in 7 (41%). Supraventricular extrasystoles had a rate of 2.3±5.5% of the total number of heartbeats and occurred in 16 (94%) patients. Six (35%) patients showed nonsustained atrial tachycardia. Ventricular extrasystoles, with a rate of 0.8±0.5% of the total heartbeats, occurred in 14 (82%) patients. The chronotropic competence was normal in 9 (53%) patients and attenuated in 8 (47%). The atrioventricular conduction (AV) was unchanged in 13 (76%) patients and there were 4 (24%) cases of first degree atrioventricular block (AVB). CONCLUSION: After the maze procedure, the values for the mean heart rate, AV conduction and chronotropic competence approach the normal range, although some cases show attenuation of the chronotropic response, first degree AV block or benign arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the occurrence of late thromboembolism after surgical repair of chronic atrial fibrillation (AF) simultaneously with repair of mitral valve using the Cox-Maze procedure. METHODS: 69 patients underwent Cox 3 procedure, with no cryoablation simultaneously with mitral valvuloplasty or prosthesis. Mean age was 49.9±13.2 years. Mean follow-up was of 31.7±19 months. Types of lesion were as follows: 33 (48%) stenoses, 23 (33%) insufficiencies, and 13 (19%) double lesions. Procedures were: 64 (93%) valvuloplasties, 3 (4%) biological and 2 (3%) mechanical prosthesis placement. There were 9 (13%) patients with previous systemic embolism and 2 (3%) had left atrial thrombi. RESULTS: Early mortality was 7% and late 1%. 2 patients (3%) were reoperated for mitral placement. At last evaluation, 10 patients (15%), were in AF. The remaining 59 (85%) were either in sinus / atrial rythm (74%) or under pacing (12%). There were no occurrence of early or late, systemic or pulmonary embolism. Permanent anticoagulation was employed in 16 cases, 10 in regular rythm and 6 in AF. The remaining 47 (75%), 2 in AF and 45 in regular rythm, did not receive anticoagulants. CONCLUSIONS: These results are in accordance with others series, where the occurrence of embolism was rare after maze procedure. Permanent systemic anticoagulation seems to be unnecessary in those cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Double immunodiffusion (DID) was used as a screening test for the diagnosis of aspergillosis. Three hundred and fifty patients were tested, all of them referred from a specialized chest disease hospital and without a definitive etiological diagnosis. When DID was positive addtional information such as clinical history and radiographic findings were requested and also surgical specimens were obtained whenever possible. Specific precipitin hamds for Aspergillus fumigatus antigen were found in 29 (8.3%) of 350 patients sera. Nineteen (65.5%) of the 29 patients with positive serology were recognized as having a fungus ball by X-rays signs in 17 or by pathological examination in 2 or by both in 8 patients. This two-year prospective study has shown that pulmonary aspergillos is a considerable problem among patiens admitted to a Chest Diseases Hospital, especially in those with pulmonary cavities or bronchiectasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple protocol is described for the silver staining of polyacrylamide gradient gels used for the separation of restriction fragments of kinetoplast DNA [schizodeme analysis of trypanosomatids (Morel et al., 1980)]. The method overcomes the problems of non-uniform staining and strong background color which are frequently encountered when conventional protocols for silver staining of linear gels. The method described has proven to be of general applicability for DNA, RNA and protein separations in gradient gels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

TT virus (TTV) is a newly described nonenveloped human virus, with a circular, negative-stranded DNA genome, that was first identified in the blood of a patient with posttransfusion hepatitis of unknown etiology. PCR primers and conditions used for TTV DNA amplification may greatly influence the level of TTV detection in serum. Three PCR assays, with different regions of the genome as targets, were used to test TTV DNA in 130 sera from children and adults visiting a hospital in the south of Brazil, most of them for routine procedure. Forty-four percent of adult sera and 73% of sera from children aged 0-10 years were TTV positive with at least one PCR assay. However, the three assays were able to detect only 33%, 35%, and 70% of the total positive samples. Our results showed a high prevalence of TTV infection in the south of Brazil, particularly among young children, and confirmed the necessity of performing several PCR assays to assess the true TTV prevalence in a determined population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the objective to evaluate PCR-mediated detection of Mycobacterium tuberculosis DNA as a diagnostic procedure for diagnosis of tuberculosis in individuals attending ambulatory services in Primary Health Units of the City Tuberculosis Program in Rio de Janeiro, Brazil, their sputum samples were collected and treated with a DNA extraction procedure using silica-guanidiniumthiocyanate. This procedure has been described to be highly efficient for extraction of different kind of nucleic acids from bacteria and clinical samples. Upon comparing PCR results with the number of acid-fast bacilli, no direct relation was observed between the number of bacilli present in the sample and PCR positivity. Part of the processed samples was therefore spiked with pure DNA of M. tuberculosis and inhibition of the PCR reaction was verified in 22 out of 36 (61%) of the samples, demonstrating that the extraction procedure as originally described should not be used for PCR analysis of sputum samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to evaluate a dot-enzyme-linked immunosorbent assay (dot-ELISA) using excretory-secretory antigens from the larval stages of Toxocara canis for the diagnosis of toxocariasis. A secondary aim was to establish the optimal conditions for its use in an area with a high prevalence of human T. canis infection. The dot-ELISA test was standardised using different concentrations of the antigen fixed on nitrocellulose paper strips and increasing dilutions of the serum and conjugate. Both the dot-ELISA and standard ELISA methods were tested in parallel with the same batch of sera from controls and from individuals living in the problem area. The best results were obtained with 1.33 µg/mL of antigen, dilutions of 1/80 for the samples and controls and a dilution of 1/5,000 for the anti-human IgG-peroxidase conjugate. All steps of the procedure were performed at room temperature. The coincidence between ELISA and dot-ELISA was 85% and the kappa index was 0.72. The dot-ELISA test described here is rapid, easy to perform and does not require expensive equipment. Thus, this test is suitable for the serological diagnosis of human T. canis infection in field surveys and in the primary health care centres of endemic regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rabies is a neurotropic disease that is often lethal. The early diagnosis of rabies infection is important and requires methods that allow for the isolation of the virus from animals and humans. The present study compared a modified shell vial (MSV) procedure using 24-well tissue culture plates with the mouse inoculation test (MIT), which is considered the gold standard for rabies virus isolation. Thirty brain samples (25 positive and 5 negative by the fluorescent antibody test) obtained from different animal species at the National Institute of Hygiene Rafael Rangel in Caracas, Venezuela, were studied by the MIT and MSV assays. Nine samples (36%) were positive at 24 h, 10 (40%) were positive at 48 h and six (24%) were positive at 72 h by the MSV assay. With the MIT assay, 76% were positive at six days post inoculation and 12% were positive at 12 and 18 days post inoculation. One sample that was negative according to the MSV assay was positive with MIT on the 12th day. The MSV procedure exhibited a sensitivity of 96.2%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value 80%. This procedure allowed for rapid rabies virus detection. MIT can be employed as an alternative method in laboratories without tissue culture facilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to quantify the colony forming units (cfu) on latex procedure gloves in the beginning, middle, and end of the containers in real (professional) and controlled (researcher) gloving situations; evaluate the microbial load of the gloves, considering the time of exposure in the environment. This comparative prospective study was conducted at an intensive care unit of a teaching hospital. The microbiological data was collected from the gloves using digital-pressure. Microbiological evaluations were performed on 186 pairs of gloves: 93 in the control group and 93 in real gloving situations. In the control group, the average cfu was 4.7 against 6.2 in the real gloving situation. Hence, no statistically significant difference was found (p=.601). In addition, the cfu values of gloves in the beginning, middle and end of the containers also did not show any significant differences (p>.05). The most common strain was Staphylococcus spp. The time of exposure in the environment did not increase the cfu value of the latex gloves.