4 resultados para Anthropomorphic phantoms
em Scielo Saúde Pública - SP
Resumo:
Abstract Objective: To evaluate three-dimensional translational setup errors and residual errors in image-guided radiosurgery, comparing frameless and frame-based techniques, using an anthropomorphic phantom. Materials and Methods: We initially used specific phantoms for the calibration and quality control of the image-guided system. For the hidden target test, we used an Alderson Radiation Therapy (ART)-210 anthropomorphic head phantom, into which we inserted four 5mm metal balls to simulate target treatment volumes. Computed tomography images were the taken with the head phantom properly positioned for frameless and frame-based radiosurgery. Results: For the frameless technique, the mean error magnitude was 0.22 ± 0.04 mm for setup errors and 0.14 ± 0.02 mm for residual errors, the combined uncertainty being 0.28 mm and 0.16 mm, respectively. For the frame-based technique, the mean error magnitude was 0.73 ± 0.14 mm for setup errors and 0.31 ± 0.04 mm for residual errors, the combined uncertainty being 1.15 mm and 0.63 mm, respectively. Conclusion: The mean values, standard deviations, and combined uncertainties showed no evidence of a significant differences between the two techniques when the head phantom ART-210 was used.
Resumo:
OBJECTIVE: To describe the lipid profile and to verify its relationship with cardiovascular disease risk factors in students at a public university in São Paulo. METHODS: After obtaining clinical, anthropomorphic, and lipid profile data from 118 students, variables of the lipid profile were related to other risk factors. RESULTS: The mean age of the students was 20.3 years (SD=1.5). The risk of cardiovascular disease was characterized by a positive family history of ischemic heart disease in 38.9%; sedentariness in 35.6%; limiting and increased total and LDL-C cholesterol levels in 17.7% and 10.2%, respectively; decreased HDL-C levels in 11.1%; increased triglyceride levels in 11.1%; body mass index >25 in 8.5%, and smoking in 6.7% of the subjects. Students' diet was found to be inadequate regarding protein, total fat, saturated fat, sodium, and fiber contents. A statistically significant association between cholesterol and contraceptive use, between HDL-C and contraceptive use, age and percent body fat, and triglycerides and percent lean weight was observed. CONCLUSION: A high prevalence of some risk factors of cardiovascular disease as well as the association between these factors with altered lipid profiles was observed in the young population studied.
Resumo:
Goethe's novel 'Elective Affinities', published in 1809, uses Bergmann's concept of 'Elective Attractions', from 1775, as a metaphor for social relations. Its analysis demonstrates the possibility of describing chemical theories, characterised by an anthropomorphic language, using poetic means. Due to the inherently poetic nature of chemical language, Nobel Laureate Roald Hoffmann (2002) suggests relaxing strictures against expressing emotions and personal motives in scientific publications, thus enabling the use ofing poetry to understand and communicate science. Based on the analysis of Goethe's novel and Hoffmann's essay, this article discusses the possibility of using poetic means to help understand chemistry and communicate its research results.
Resumo:
The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.